background image

Operation Manual and Parts Directory

Glastender, Inc. · 5400 North Michigan Road · Saginaw, MI · 48604-9780 

800.748.0423 · 989.752.4275 · Fax 989.752.4444 · www.glastender.com

LC65, LC85, LC86, LC44, LC47

D

raft

 P

ro

 r

emote

 G

lycol

 l

ine

 c

hillers

© 2007 Glastender, Inc.

 

LC44

LC65

Rev. 08-26-08

Summary of Contents for LC44

Page 1: ...ory Glastender Inc 5400 North Michigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 989 752 4444 www glastender com LC65 LC85 LC86 LC44 LC47 Draft Pro Remote Glycol Line Chillers 2007 Glas...

Page 2: ......

Page 3: ...86 3 LC44 4 LC47 5 Warranty 6 7 Inspection Upon Arrival 8 Set Up Remote Glycol Line Chiller 8 Electrical Hook Up 8 Glycol Line Connection 8 Glycol Filling 9 Unit Start Up 9 Cold Control Adjustment 10...

Page 4: ...2 cm Electrical 115V 1 phase 60 Hz 10 8 full load amps 230V 1 phase 50 Hz 5 8 full load amps Dedicated 15 amp circuit is required Includes a 8 foot grounded cord Refrigeration 1 3 HP R134a lift out hi...

Page 5: ...ectrical 115V 1 phase 60 Hz 10 8 full load amps 230V 1 phase 50 Hz 5 8 full load amps Dedicated 15 amp circuit is required Includes a 8 foot grounded cord Refrigeration 1 3 HP R134a lift out high temp...

Page 6: ...hase 60 Hz 16 0 full load amps 230V 1 phase 50 Hz 8 0 full load amps Dedicated 20 amp circuit is required Includes a 8 foot grounded cord Refrigeration 1 2 HP R134a lift out high temperature condensin...

Page 7: ...Hz 16 0 full load amps 230V 1 phase 50 Hz 8 0 full load amps Dedicated 20 amp circuit is required Includes a 8 foot grounded cord Refrigeration 1 2 HP R134a lift out high temperature con densing unit...

Page 8: ...th 25 125 63 8 cm Electrical 230V 1 phase 60 Hz 12 4 full load amps Dedicated 20 amp circuit is required Includes a 8 foot grounded cord Refrigeration 3 4 HP R134a lift out medium temperature con dens...

Page 9: ...A Glastender Inc warrants all products to be free of defects in material and workmanship Within one year from date of installation or 15 months from date of factory shipment whichever occurs sooner Gl...

Page 10: ...e exchanged at a local wholesaler whenever possible If a compressor is not available locally the factory should be contacted B If the replacement compressor is obtained from the factory in order to re...

Page 11: ...ry to locate the unit on top of the walk in cooler or on the floor NOTE Do not locate the glycol chiller in the walk in cooler as the cold ambient temperature will reduce the cooling performance of th...

Page 12: ...ect and use only a propylene glycol product that meets FDA Food and Drug Administration regulations as a food grade product Any substitution of food grade glycol with automotive anti freeze or other p...

Page 13: ...ines enables the temperature inside the trunk line to stabilize before beer is introduced Once the refrigeration unit and the glycol recirculating pump have operated for sixty 60 minutes or more the b...

Page 14: ...wiring connections are secure Refrigeration Compressor Runs But Stops Check for dirt build up on condenser coil surface Check that there is no obstruction of air flow into the cabinet Ensure that enou...

Page 15: ...ANGE LENGTH WITHOUT CONSULTING THE FACTORY TWO GLYCOL LINES GO THRU CHASE SO GLYCOL CAN CIRCULATE BACK TO THE LINE CHILLER MUST INSULATE LINES INSIDE WALK IN TO PREVENT ICE BUILD UP INSULATED LINE CON...

Page 16: ...tender Inc 5400 North Michigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 989 752 4444 www glastender com 13 LC65 Compressor and Related Parts 1 2 19 7 9 8 6 11 10 12 3 18 17 14 15 16 13...

Page 17: ...nser coil 125 00 6 09000296 GT 032626 Evaporator 110 00 7 09000340 GT 035119 Recirculating pump motor 270 00 8 09000331 GT 034536 Pump glycol 60 gph brass 190 00 9 00000006 GT 031115 Clamp recirculati...

Page 18: ...tender Inc 5400 North Michigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 989 752 4444 www glastender com 15 LC85 Compressor and Related Parts 1 2 3 4 5 16 6 7 8 9 10 11 12 13 14 15 17 1...

Page 19: ...125 00 7 09000291 GT 032598 Evaporator coil LC 83 84 85 Copper 110 00 8 09000340 GT 035119 Recirculating pump motor 270 00 9 09000331 GT 034536 Pump glycol 60 gph brass 190 00 00000006 GT 031115 Clamp...

Page 20: ...stender Inc 5400 North Michigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 989 752 4444 www glastender com 17 LC86 Compressor and Related Parts 2 1 4 3 6 13 5 7 9 16 11 12 15 14 17 18 8...

Page 21: ...7 09000290 GT 032597 Evaporator coil copper LC 86 220 00 8 09000340 GT 035119 Recirculating pump motor 1 3 hp 115v 270 00 9 09000331 GT 034536 Pump glycol 60 gph brass 190 00 00000006 GT 031115 Clamp...

Page 22: ...tender Inc 5400 North Michigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 989 752 4444 www glastender com 19 LC44 Compressor and Related Parts 3 8 10 9 7 19 11 2 16 13 14 1 6 5 15 17 4 1...

Page 23: ...170 00 7 09000289 GT 032595 Evaporator coil copper LC 44 45 200 00 8 09000340 GT 035119 Recirculating pump motor 1 3hp 115v 270 00 9 09000331 GT 034536 Pump glycol 60 gph brass 190 00 10 00000006 GT...

Page 24: ...nder Inc 5400 North Michigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 989 752 4444 www glastender com 21 1 2 9 11 10 8 13 12 14 3 18 16 17 15 7 6 19 20 4 5 LC47 Compressor and Related...

Page 25: ...assembly 95 00 7 09000294 GT 032620 Condenser coil 3 4 hp LC 221 95 8 09000486 GT 032629 Evaporator Coil LC47 200 00 9 09000342 GT 035123 Recirculating pump motor 280 00 10 09000331 GT 034536 Pump gl...

Page 26: ...ne chiller stand 16 ga galvanized steel 329 70 LCS G A line chiller stand is 26 1 2 wide by 39 high by 24 deep and comes with adjustable feet for leveling The bottom shelf is at the 8 high level The t...

Page 27: ..._____________________ _________________________________________________________________________________________ ________________________________________________________________________________________...

Page 28: ......

Reviews: