background image

User

Instructions

In the interest of continuously improving the BoilerMate 
A-Class range Gledhill Building Products Ltd reserve the 
right to modify the product without notice and in these 
circumstances this booklet, which is accurate at the time 
of printing, should be disregarded.

Mitsubishi will provide warranty for Approved Ecodan 
Installers whom purchase the units direct from 
Mitsubishi.

      

 WARNING

•  There are no user adjustable parts inside the appliance.  

Tampering with sealed components will invalidate the 
warranty and could also damage the appliance and 
make it unsafe to use.

•  If it is known or suspected that a fault condition exists 

on the appliance it must be corrected as soon as 
possible by a competent person.

• 

DON’T

 place any clothing or other combustible 

materials against or on top of this appliance.

Summary of Contents for BoilerMate HP-DEM-A

Page 1: ...warranty for Approved Ecodan Installers whom purchase the units direct from Mitsubishi WARNING There are no user adjustable parts inside the appliance Tampering with sealed components will invalidate the warranty and could also damage the appliance and make it unsafe to use If it is known or suspected that a fault condition exists on the appliance it must be corrected as soon as possible by a comp...

Page 2: ...ology is well proven Your air source heat pump will be outside of your property Your air source heat pump uses small amountsofelectricitytoworkandfunctions by taking in large quantities of air and extracting the heat from it For this reason your heat pump is using a renewable energysourceandisexceptionallyefficient because onaverage ituses1kWofelectrical energy and converts it into over 3kW of hea...

Page 3: ...rmostat or thermostatic radiator valves It will supply heating and powerful hot watermoreefficientlythanconventional systems It eliminates the traditional cold water tankintheloftandthereforeremovesthe risk of contamination and or freezing It is fitted with an electric emergency back upforHEATINGANDHOTWATER called Switch which can be activated in the unlikely event that there is a problem with the...

Page 4: ... constant timed or off It is normal toset the timer to suit your individual requirements The temperature in your house is set by a room thermostat thermostatic radiator valves and these should be adjusted to suit your individual requirements Your hot water is also controlled by the timer which is fitted to the front panel of your BoilerMate The timer provides you with the option of choosing consta...

Page 5: ...howers Because the BoilerMate A Class HP DEM A system uses the pressure from your cold watermains thesecisternsarenotrequired which removes any worries about freezing or contamination of the cold water system from insects dust birds etc and leaves more space for storage should you decide to use it Depending on the height of your airing cupboard it occasionally may be necessary to position the smal...

Page 6: ...umpto prevent seizing during prolonged unused heating periods In normal circumstances it should only be required to adjust the time clock on your BoilerMate to suit your needs and the instructions for this are described in detail later in this booklet If your hot water or heating system should failtooperatesatisfactorily youwillneedto operate the SWITCH option which is fitted toyourBoilerMate See ...

Page 7: ...d your air source heat pump boiler cease to operate If you believe the boiler has stopped working and you are unable to restore heating and hot water activate Switch and call the boiler service engineer SWITCH technologysimplyandinstantlyintroduces an electric heating source within the BoilerMate to ensure that your hot water andheatingcontinuetooperateatreduced performanceuntilyoucanhaveyourboile...

Page 8: ...nt panel user controls are shown in the picture below and their functions are described opposite Four different windows can be displayed in the visual display panel on the front of the appliance Front Panel Controls ...

Page 9: ...can be returned to normal operation by pressing the Switch button for at least 5 seconds Fault Condition Display Window If a fault occurs with the BoilerMate appliance the window will automatically display the fault condition The fault indication will flash to draw your attention Please give this code to an Approved Ecodan Installer AEI They will have the ability to decode this and ensure the corr...

Page 10: ...ess the adjustment key to select timed or manual operation in Channel 2 Channel Number 1 2 3 4 5 6 7 14 16 18 20 22 24 Menu OK Res 1h Timed Automatic Manual Continuous Select summer winter times Reset Confirmation of programming Summer winter clock changes Time display Switching status display See below Manual Automatic operation modes Weekday display 24h or am pm setting Adjustment keys Overview ...

Page 11: ...timemode When the clocks change subsequently the 1h button needs to be pressed to alternately deduct or add the hour Setting Switching Times This timeclock allows you to use 3 preset programs modify these or set your own programs The preset programs are as follows To select the preset programs you will need to press the Reset key to place the clockinresetmodeandset adjustthetime settings using the...

Page 12: ...heatingtime settings This should be set to suit your lifestyle requirements The timeclock can be set to your own programs in the same way as described previously by pressing the Menu button to place the timeclock in the menu mode instead of the reset mode Deleting Switching Times To delete any switching times press the Menu button and then OK until you get to the on time of the program to be delet...

Page 13: ...Page 13 ...

Page 14: ...Page 14 ...

Page 15: ...Page 15 ...

Page 16: ......

Page 17: ......

Reviews: