Page 2: ......

Page 3: ...scription 5 2 2 Accessories 5 3 Product documentation 5 3 1 Document storage 5 3 2 Explanation of symbols 5 4 Safety 6 4 1 What to do if you smell gas 6 4 2 Safety recommendations 6 4 3 Safety regulations 7 5 Guarantee Responsibility 8 5 1 Detailed guarantee 8 5 2 Appliance use manufacturer responsibility 8 6 Recycling 9 6 1 Appliance 9 6 2 Packaging 9 7 Clearances 9 TABLE OF CONTENTS ...

Page 4: ... devices 14 10 1 Boiler Shutdown 14 10 2 Protecting against frost 14 10 3 Condensate Drain Blockage 14 10 4 Safety Discharge Valve 14 11 Appliance maintenance and servicing 15 11 1 Cleaning 15 11 2 Regular Servicing 15 11 3 Spare Parts 15 11 4 Sealed Water Systems 15 12 Tips for saving energy 16 13 Contact your after sales organisation 16 TABLE OF CONTENTS ...

Page 5: ...ler i Do not forget to read the chapters Safety and Guarantee where you will find important information for your safety 1 2 Guarantee Pack The pack contains the letter of introduction and the guarantee The extended guarantee is supplied loose and we recommend that you should read it Complete and return as soon as possible your guarantee registration card If your guarantee registration card is miss...

Page 6: ...e UK and to encourage regular servicing to optimise safety efficiency and performance 1 5 Quick reference guide We designed this Quick reference guide so that you can start using your appliance right away This Quick reference guide assumes that the appliance have been installed and commissioned by a competent person Benchmark is managed and promoted by the Heating and Hotwater Industry Council For...

Page 7: ...the appliance should only be carried out by a competent person They are responsible for the installation and the commissioning in accordance with standards in force You should also consult a competent person for maintenance and repair of the appliance as well as for any adjustment necessary 2 2 Accessories The Ultracom 2 is compatible with most makes of programmable room thermostats The boiler can...

Page 8: ...y affect the operation of your appliance you should consult your installer for advice before carrying out any work Do not expose the appliance to high humidity Do not use or store explosive or inflammable materials e g petrol aerosols solvents chlorine based detergents paint glue etc in the same room as the appliance Under certain conditions these substances can prove to be corrosive Do not touch ...

Page 9: ...ommon isolator The colours of three core flexible cable are blue neutral brown live green and yellow earth Testing and Certification This boiler is certificated to the current issue of EN 483 for performance and safety It is important that no alteration is made to the boiler unless approved in writing by Glow worm Any alteration not approved by Glow worm could invalidate the certification boiler w...

Page 10: ...ntee period still benefit from a 12 month warranty from the date of issue by the manufacturer 5 2 Appliance use manufacturer responsibility Servicing maintenance should be carried out by a competent person approved at the time by the Health and Safety Executive in accordance with the rules in force in the countries of destination The guarantee is applicable on the condition that The appliance is i...

Page 11: ... appliance must not be disposed of with household waste that it should be selectively collected for energy recovery reuse or recycling Take the appliance to an appropriate collection point i By complying with this directive you will contribute to the preservation of natural resources and the protection of human health 6 2 Packaging The competent person who installed the appliance must sort the was...

Page 12: ...erational if Glow worm external controls are fitted 2 Display 3 Reset button 4 On Off button 5 Central heating temperature control button 6 Mode selection button 2 1 3 4 5 Key 1 Domestic hot water temperature This mode is only operational if Glow worm external controls are fitted 2 Fault symbols 3 Central heating system pressure 4 Burner operating indicator 5 Central heating temperature ...

Page 13: ...epending on the selected operation and controls display the temperature settings and water pressure Turning off Press the on off button 4 The appliance is no longer powered and the display switches off a If you intend to leave your property empty for a prolonged period please refer to the Appliance Safety Devices section 8 3 User Controls Selection of operating mode s To change the operating mode ...

Page 14: ...n to adjust the temperature of the water in the heating circuit Temperature of the water C min 10 recommended 50 max Pre set by the installer NOTE If a Glow worm outdoor sensor or Glow worm intelligent controls are fitted the temperature of the water in the heating circuit is calculated by the boiler It is neither necessary nor possible to adjust it manually ...

Page 15: ...ical power comes back on the appliance automatically comes back into service If the fault persists contact your Installation Servicing company or Glow worm Service Fault Press on the reset button Wait for 5 seconds If the fault persists and the symbol xx appears contact your Installation Servicing company or Glow worm Service Lack of water in the installation 0 5 bars Open the filling tap located ...

Page 16: ...If the boiler is in Domestic Hot Water mode only the frost protection system is also active System Protection The boiler alone cannot ensure that the installation is protected against frost NOTE Any other exposed areas of the system should be protected by a separate frost thermostat In case of prolonged absence where power to the dwelling and the boiler is switched off contact your Installation Se...

Page 17: ...o home improvements in the optional documents section of the Home Information Pack To obtain service please call your installer or Glow worm s own service organisation 11 3 Spare Parts In order to guarantee the safe and prolonged life of the product insist that only the manufacturer s genuine spare parts are used Do not use reconditioned or copy parts that have not been clearly authorised by Glow ...

Page 18: ...fer simple effective advice about saving energy Regular servicing of your boiler will help maintain its efficiency servicing once a year is recommended Turn your thermostat down Reducing your room temperature by 1 C could cut your heating bills by up to 10 percent Set your heating and hot water at the time controller to come on only when required rather than all the time 13 Contact your after sale...