INSTALLER! PLEASE LEAVE WITH HOMEOWNER

Gas logs are to be burned only in approved woodburning Fireplace with adequate chimney draft. When burning, the chimney 
damper must be FULLY OPEN. Log set must be installed in fireplace which operates properly when wood fires are burned.

IMPORTANT INFORMATION 

CHECK TO BE SURE LOG SET IS FOR PROPER GAS TYPE

Log sets are designed for use with Natural Gas, unless clearly labeled for Propane (LP). Never use Propane Gas 
in a log set designed for Natural Gas, or Natural Gas in a log set designed for use with Propane Gas.

•  For best results, natural gas pressure must be 7" to 10 1/2" water 

column.

•  To simulate real wood burning, the gas burner is designed to burn 

a yellow flame. It is normal for the logs to soot-up. The soot can 

easily be removed with a vacuum cleaner or a soft brush.

•  A fireplace screen must be in place when the appliance is operating 

and, unless other provisions for combustion air are provided, the 
screen shall have an opening (s) for introduction of combustion air.

•  If used with glass fireplace doors, burn with doors in open position.
•  Do not burn wood or other items with log set.

FOR YOUR SAFETY 

If you smell gas:

1. Open Windows.
2. Don't Touch electrical switches.

3. Extinguish any open flame.
4. Immediately call your gas supplier.

FOR YOUR SAFETY

Do not store or use gasoline or other flam

-

mable vapors and liquids in the vicinity 
of this or any other appliance.

Listing

1269

The installation, including provisions  for combustion and ven

-

tilation air, must conform with local codes or, in the absence of 

local codes, with the national fuel Gas Code, ANSI Z223.1-1988 
and NFPA54-1988.

The appliance and its individual shutoff valve must be discon

-

nected from the gas supply piping system when testing at test 

pressures in excess of 1/2 psig.

The appliance must be isolated from the gas supply piping system 

by closing its individual manual shutoff valve during any pres-
sure testing of gas-supply system at test pressures equal to or less 

than 1/2 psig. This is accomplished by closing the gas supply line 
valve, which is required by NFPA 54, section 5.54.

The minimum inlet gas supply pressure for the purpose 
of input adjustment is 7" WC for Natural Gas and 11" 

WC for Propane Gas.

The maximum inlet gas supply pressure for this burner 
is 10.5" for Natural Gas and 13" for Propane Gas.

MINIMUM  FIREPLACE SIZE

 (No pilot valve installed)

Log Set Size 

Depth  Height  Front

 

 

 

 

Opening

 

18" 

14" 

16" 

24"

 

21" 

14" 

16" 

28"

 

24" 

15" 

16" 

30"

 

30" 

16" 

16" 

36"

 

36" 

17" 

16" 

42"

Please Note: It is important that you read instructions before installing or operating gas logs

GENERAL INFORMATION

GAS LOGS

INSTALLATION AND OPERATING INSTRUCTIONS

Summary of Contents for Radco

Page 1: ...guish any open flame 4 Immediately call your gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance Listing 1269 The installation including provisions for combustion and ven tilation air must conform with local codes or in the absence of local codes with the national fuel Gas Code ANSI Z223 1 1988 and NFPA54 1...

Page 2: ... 30 and 36 sets are packed in 3 boxes 2 for logs and 1 for component parts Components Parts For Natural Gas ITEM 1 Damper Clamp 2 Log Grate 3 Gas Pan Burner 4 Cast Iron Burner Cap 5 Orifice 6 Aluminum Connector 7 Silica Sand Vermiculite supplied with L P sets 8 Black Volcanic cinders 9 Glowing Embers w hardware kit 10 Ceramic Logs Number of logs per set varies with set size Maintenance Removal of ...

Page 3: ...rs over brass air mixer attached to burner pan Air mixer holes must not be obstructed 7 Evenly spread glowing ember material over the burner pan and replace grate 8 Place logs on grate A The longest log is the bottom front log B Next longest log is the bottom back log to be positioned 3 behind the front log C The positioning of the top logs is a matter of the installer s choice Note Illustration s...

Page 4: ...step one LIMITED WARRANTY Golden Blount Gas Logs are warranted against defective materials and or workmanship for as long as you own them Burner pan assemblies are guaranteed for five years from date of purchase Safety Pilot Assemblies are covered for one year This warranty does not cover parts subjected to misuse abuse improper handling or improper installation The GB warranty specifically exclud...

Reviews: