Summary of Contents for Soul S5110/ART 7W

Page 1: ...Cód 50122126 TS5110 ART 7W ES REV 0119 Soul kit G2 2 wire installation Art 7W monitor with Wi Fi connectivity Instructions manual ...

Page 2: ...n already network connected monitor 24 Advanced settings of a registered monitor 25 to 26 Main screen 27 Communication screen 28to 29 Installation diagrams 30to 34 Wiring sections and distances 30 One apartment with one access door and one monitor 30 One apartment with two access doors and one monitor 30 One apartment with two access doors and up to four monitors daisy chain connected 31 One apart...

Page 3: ...ary to contact the door panel from the main menu To establish communication click on the screen on the off hook icon The led on the door panel will light up The communication will last for 90 seconds or until you click on the hanging icon Once the communication is complete the led will turn off and the system will be free To open the door or activate the auxiliary output of the door panel click on...

Page 4: ...stall the power supply in a dry protected and ventilated place Under no circumstances obstruct the ventilation grilles Use a DIN 46277 guide for fastening 8 elements Remember that the current regulations require to protect the power supply with a circuit breaker To avoid electric shock do not remove the protection cover without first disconnecting the power supply Re install it once all connection...

Page 5: ...t vision illumination E Protective polycarbonate F Name holder and proximity reader G Speaker grille H Colour camera I Push button s J Microphone hole K Fixing screw L Proximity reader M Wall fixing holes x3 N Proximity reader sealing gasket O Wiring connectors P Cable gland seal Q Proximity reader connector R Configuration switches S Audio level potentiometer T Proximity reader configuration push...

Page 6: ...ble gland seal 4 Fix the door panel to the wall using the screws provided 5 Connect the cables to the removable wiring connectors following the indications of the installation diagrams Before replacing the proximity reader and closing the door panel make the necessary adjustments programming of proximity keys adjusting the audio level as indicated throughout this manual Make sure that the sealing ...

Page 7: ...all to apartment n 1 2 the two lower push buttons call to apartment n 1 the two upper push buttons call to apartment n 2 4 each push button calls to a different apartment n 1 to 4 Switch 4 Disables door panel acoustic tones OFF ON 4 apartments Audio level adjustment If after the start up of the system you consider that the audio volume on the door panel is not suitable use the adjustment potentiom...

Page 8: ...letion of user keys can be done with the door panel closed Adding user keys Approach the registration key to the reader the door panel will emit four short tones Approach one by one the user keys that you want to add emitting the door panel a short tone for each key added After ten seconds have passed since adding the last key the door panel will emit a long tone to confirm the completion of the p...

Page 9: ... Hidden push button Starts ends communication D Orientation dots for blind people E Touch screen F Hidden push button to activate the lock G Microphone H Micro SD card slot I Wall bracket slots x4 J Configuration switches K Wiring connectors L UID monitor sticker SA A E B C D F G GND HZ HZ BUS BUS 24V GND ON 1 2 3 4 5 6 7 8 H I J K L I I I UID mnvx8d8uskpv K SOUL S5110 ART 7W VIDEO INTERCOM KIT ...

Page 10: ...rs are removable and are supplied in a separate bag Once the connectors are wired place them in their position BUS BUS communication bus polarity free 24V GND local power supply input SA GND ringer output 50mA 12V maximum HZ HZ doorbell push button input SA GND HZ HZ BUS BUS 24V GND ON 1 2 3 4 5 6 7 8 Configuration switches R Switches 1 to 5 Assign the monitor address corresponding to its push but...

Page 11: ...will be shown Allows to change system settings Switches off the monitor screen Apaga la pantalla del monitor Indicates that the inserted micro SD card must be formatted from the monitor Press to access the storage menu and format the card Press to enable or disable Wi Fi transmission The icon will change color enabled white disabled off and the notification icon will light depending on the status ...

Page 12: ...rning the monitor to the settings menu Use icon to return to the main menu Settings Do not disturb Language Storage Time Date WiFi Ringtone About Background Italiano Magyar Nederlands Norsk Português русский Slovenský Svenska English Español Eλληνικά Français اﻟﻌرﺑﯾﺔ Čeština Dansk Deutsch Language SOUL S5110 ART 7W VIDEO INTERCOM KIT ART 7W G2 MONITOR ...

Page 13: ...g the monitor to the settings menu Ringtone 1 6 3 6 5 6 6 6 Door panel 1 Door panel 2 Doorbell Intercom Background 22 02 2022 02 03 01 Month 22 23 21 Day 2022 2023 2021 Year 24H 00 01 23 Hour 14 15 13 Min Time Date It allows to adjust the date and time of the system as well as the presentation format Change the values by sliding up or down and use the arrows to change the formats Validate the chan...

Page 14: ... SD card and format the card Any of these actions will require your confirmation Use icon to return to the settings menu Storage Automatic erasing Picture Copy Picture Video Format Internal memory Micro SD In the Do Not Disturb settings you can set a time period in which the monitor will not ring when receiving calls To do this activate the timer function and choose the time period From the main m...

Page 15: ... restart the Wi Fi parameters using the icon Remember that only the master monitor can activate the Wi Fi transmission The Wi Fi menu shows information about the identity of the monitor UID the name of the network to which it is connected SSID and the signal strength Use G2Call application to connect the monitor to your Wi Fi network as detailed below Choose using the arrows the time you want to e...

Page 16: ...rce as long as the system has more than one door panel or has an external camera connected and their visualization has been activated see page 35 It is possible to change the image source at any time Activates the lock release or device connected to the CV output of the door panel for 3 seconds factory value programmable by the installer During activation the notification icon will light Activates...

Page 17: ...rs of the image brightness contrast and color the volume of the ringing tone during visualization and the audio level of the speaker during communication Press the icon and use the sliders to make the adjustments Clicking on the icon again the settings window will disappear 02 02 2222 Door panel 1 11 17 10 1 2 SOUL S5110 ART 7W VIDEO INTERCOM KIT ART 7W G2 MONITOR ...

Page 18: ...on to return to the main menu Intercom Slave 3 Slave 2 Slave 1 Master All Calling Internal intercom Select the monitor with which you want to communicate The monitor that appears selected by default it s yours You will find information about the monitor s address in the About menu If you select the All option the rest of the monitors will receive the call establishing communication with the first ...

Page 19: ...ad To make the call press on the icon the message Calling appears on the screen The main monitor of the called apartment will show the message Calling from followed by the calling monitor address To cancel the call press on the icon appearing the message Call finished SOUL S5110 ART 7W VIDEO INTERCOM KIT ART 7W G2 MONITOR Intercom menu ...

Page 20: ...e top of the screen Use the scroll arrows to access the rest of the pages The symbol indicates that the recording has not been displayed Use icon to return to the main menu To delete one or more recordings from the list use the icon Click on the recordings you want to delete or use the icon to select them all Confirm your selection using the icon a warning screen will ask for your final confirmati...

Page 21: ... or previous recording From this screen you can also delete the recordings individually always requiring confirmation Use the icon to play the pictures in sequence if it is a video the recording will start playing Tap the screen to stop playback Use icon to return to the recordings list 014 020 SOUL S5110 ART 7W VIDEO INTERCOM KIT ART 7W G2 MONITOR Recordings menu ...

Page 22: ... for the correct operation of the application During the registration process some phones experience problems while they are connected to the mobile phone network We recommend that you put your mobile in airplane mode with Wi Fi activated during the registration process Activate the Wi Fi functionality of the main monitor using the icon from the main menu Go to the Wi Fi screen in the settings men...

Page 23: ...o differentiate it from other possible monitors registered on your phone The factory default for the connection password is 1234 This password can only be changed once the monitor is registered If the monitor is connected to a second door panel or CCTV cameras indicate it If on the contrary the pairing process failed go to the Wi Fi screen of the monitor settings menu and verify that it s connecte...

Page 24: ...anually If you choose the Search option the application will show you the identifiers UID of the connected monitors Select the monitor you want to register in your application showing the basic monitor configuration screen If you choose the Add manually option you can scan the QR code located on the back of the monitor with your phone or manually enter the UID that can be found in the Wi Fi screen...

Page 25: ...tings This password will be requested to disable the function again Use to change the settings Once changes are made save changes using icon If you want to discard changes made use icon Password It allows to change the connection password to the monitor It is the same password used to open the door if the function has been activated Once the password has been changed save the changes using the ico...

Page 26: ...same location as the monitor Notification To be able to receive call transfers from this monitor it will be necessary to activate the notification function Disable this function if all you want is to connect to the system without being called FW version It shows the FW version of this monitor and the latest version on the remote communications server being possible to update it The application inf...

Page 27: ...sing the icon The icon will take you to the screen that shows the snapshot pictures or videos recorded from the application Click on any of the recordings to view it in full screen from where you can also share or delete it individually By clicking on the icon you can delete and share several or all of the recordings simultaneously To do this use and icons To access the application settings press ...

Page 28: ... process The initial state depends on the monitor preview settings page 25 Activate or deactivate the phone s microphone during the communication process In the communication mode Push to talk is deactivated Takes a snapshot picture 2018 06 13 17 45 39 2018 06 13 17 45 39 Door panel 1 Door panel 1 1 2 Push to talk Villa 2018 06 13 17 45 39 Door panel 1 SOUL S5110 ART 7W VIDEO INTERCOM KIT G2Call A...

Page 29: ...d door panel or camera It will be necessary to enter a password for activation if you defined it on page 25 1 2 1 2 3 4 5 6 7 8 9 0 Villa 2018 06 13 17 45 39 Door panel 1 It allows to change the quality of the video signal to adapt it to the type of data connection Switches between full screen mode horizontal orientation of the phone and normal screen mode portrait orientation 2 1 1 2 3 4 5 6 7 8 ...

Page 30: ...PANEL 2 BUS BUS BUS BUS BUS BUS BUS BUS BUS BUS Wiring sections and distances Cable type A B C 2 x 0 75mm AWG18 30 m 30 m 15 m 60 m 60 m 30 m 60 m 60 m 30 m CAT5 RAP GTWIN HF The maximum number of monitors per apartment is 4 The maximum number of monitors connected in daisy chain configuration is 12 A Distance between power supply and the farthest door panel B Distance between power supply and the...

Page 31: ...VE 2 MONITOR APARTMENT 1 SLAVE 3 MONITOR DOOR PANEL 1 DOOR PANEL 2 BUS IN BUS IN BUS out A BUS out B BUS out C BUS out D D4L ART ON One apartment with two access doors and up to four monitors daisy chain connected CAUTION BUS M BUS PL ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 L N Mains 100 240Vac APARTMENT 1 MASTER MONITOR APARTMENT 1 SLAVE 1 MONITOR ON 1 2 3 4 5 6 7 8 APARTMENT ...

Page 32: ...6 7 7 8 8 ON ON 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 L N Mains 100 240Vac APARTMENT 1 MASTER MONITOR APARTMENT 2 MASTER MONITOR APARTMENT 1 SLAVE 1 MONITOR APARTMENT 2 SLAVE 1 MONITOR APARTMENT 1 SLAVE 2 MONITOR APARTMENT 2 SLAVE 2 MONITOR APARTMENT 1 SLAVE 3 MONITOR APARTMENT 2 SLAVE 3 MONITOR DOOR PANEL 1 DOOR PANEL 2 BUS IN BUS IN BUS out A BUS out B BUS out C APARTMENT 3 APARTMENT 4 BUS out D 24V 2...

Page 33: ... example the connection of a secondAC lock release The relay can switch loads of 6A 24V Activation is done through the icon The activation time is 3 seconds it being possible to adjust it between 0 5 and 10 seconds see page 36 2 If the lock release you are going to use isAC use a relay and a transformer suitable for consumption The example shows a Golmar SAR 12 24 relay and a TF 104 transformer 12...

Page 34: ...econds it being possible to adjust it between 0 5 and 10 seconds see page 36 It is possible to connect an analog CCTV camera to each of the door panels and they can be viewed see page 35 from the monitor or the mobile application The camera must have local power Connect the doorbell push button to the HZ inputs of the monitor you want to ring CV GND BUS C CV CCTV AP AP BUS NA CV GND BUS C CV CCTV ...

Page 35: ...aller menu from the monitor Go to the About screen in the settings menu page 15 and press five consecutive times on the icon at the top right of the screen appearing a keyboard for entering the codes The codes must be entered one by one preceded by the asterisk symbol and validated by the icon If the code entered is valid the message OK will be displayed otherwise the message ERROR will be display...

Page 36: ...up to 219 10s 203 3s Relay From 300 0 5s up to 319 10s 303 3s Remote activation input configuration Factory value Delay From 400 0 5s up to 419 10s 403 3s Operating output 430 lock release or 431 relay 430 lock release SOUL S5110 ART 7W VIDEO INTERCOM KIT SPECIAL CODES ...

Page 37: ...37 SOUL DOOR PANEL INSTALLATION TEMPLATE SOUL S5110 ART 7W VIDEO INTERCOM KIT ...

Page 38: ...38 SOUL S5110 ART 7W VIDEO INTERCOM KIT ART 7 MONITOR INSTALLATION TEMPLATE ...

Page 39: ...39 NOTES SOUL S5110 ART 7W VIDEO INTERCOM KIT ...

Page 40: ...Golmar se reserva el derecho a cualquier modificación sin previo aviso Golmar se réserve le droit de toute modification sans préavis Golmar reserves the right to make any modifications without prior notice GOLMAR S A C Silici 13 08940 Cornellá de Llobregat SPAIN ...