GMVC80(A) / GCVC80(A)

Heating Input:   60,000–100,000 BTU/h

Contents

Nomenclature ........................................ 2

Product Specifications

 ........................... 3

Dimensions

 ............................................ 5

Airflow Data

 ........................................... 7

Accessories

 ............................................ 8

Wiring Diagram  ................................... 10 

Standard Features

• 

Integrated communicating ComfortBridge™ technology

• 

Two-stage gas valve provides quiet, 

 

economical heating

• 

Commissioning and diagnostics via on board 

 

Bluetooth with the CoolCloud™ phone and 

 

tablet application 

• 

Efficient and quiet variable-speed ECM 

 

circulator motor gently ramps up or down 

 

according to heating or cooling demand

•  SureStart® Silicon Nitride igniter  

designed for long igniter life

• 

Self-diagnostic control board with constant memory 

fault code history output to a triple 7-segment display 

• 

Low constant fan speed circulates air 

 

throughout the home 

• 

Quiet, two-speed induced draft blower

• 

California Low NOx emissions-compliant 

 

models available

• 

Can no longer be installed in California’s 

South Coast Air Quality Management District 

(SCAQMD) on or after October 1, 2019.

  

• 

AHRI Certified; ETL Listed

Cabinet Features

• 

Fully insulated, heavy-gauge steel cabinet 

with durable baked-enamel finish

• 

Multi-position installation: 

 

GMVC80: upflow, horizontal left or right

 

GCVC80: downflow, horizontal left or right

• 

Removable bottom for side- or 

 

bottom-return applications

• 

Convenient left or right connection 

 

for gas/electric service

• 

Cabinet air leakage ≤ 2%

• 

Coil and furnace fit flush 

for most installations

* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive 

the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year 

Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be 

completed within 60 days of installation. Online registration is not required in California or Québec.

Summary of Contents for GCVC800603B A Series

Page 1: ...out the home Quiet two speed induced draft blower California Low NOx emissions compliant models available Can no longer be installed in California s South Coast Air Quality Management District SCAQMD...

Page 2: ...ation NOx M Upflow Horizontal N Natural Gas C Downflow Horizontal X Low NOx Motor Cabinet Width V Variable Speed ECM ComfortBridge A 14 C 21 E Multi Speed ECM S Single Speed B 17 D 24 Gas Valve Maximu...

Page 3: ...Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM Vent Diameter 4 4 4 4 4 4 4 No of Burners 3 3 4 4 4 4 5 Electrical Data Min Circuit Ampacity 7 75 10 6 7 75 7 75 10 6 10 6...

Page 4: ...Data Min Circuit Ampacity 7 75 7 75 10 6 10 6 Max Overcurrent Device amps 15 15 15 15 Ship Weight lbs 105 109 125 129 Natural Gas BTU h for altitudes above from 0 to 4 500 above sea level reduce inpu...

Page 5: ...enclosure where accessibility clearances are greater Refer to the appropriate USA and Canadian codes In the USA the National Fuel Gas Code NFPA 54 ANSI Z223 1 In Canada the Canada National Standard o...

Page 6: ...B 1 0 3 6 1 1 Approved for line contact in the horizontal position 24 clearance for serviceability recommended Single Wall Vent SW to be used only as a connector Refer to the venting tables outlined i...

Page 7: ...d cfm forhiheat expected temperature rise 810 55 990 60 1070 55 1475 50 980 45 890 50 Maximum cfm for hi heat expected temperature rise 1400 32 1400 42 2200 27 2200 34 1400 32 1760 25 NOTE Low Heat CF...

Page 8: ...bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity GMVCContinuousFanSpeeds Model Furnace Maximum CFM Continuous Fan Speed GMVC800603B A 1400 350 1400 GMVC800604B A 17...

Page 9: ...UT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 8...

Page 10: ...ge non communicating outdoor units 4 Optional Use the Heating Trim Menu HtF to adjust the heat pump airflow from 10 to 10 2 increments This applies for 2 stage communicating outdoor units and single o...