background image

VGL-100

Please read instructions before use.

VGL-100

Valve Guide Level

VGL-101

Replacement Vial

Also available from Goodson:

LEV-8 

8 inch Cylinder Head Level

LEV-8-1

Replacement Vial

LEV-12

12 inch Cylinder Head Level

LEV-12-1

Replacement Vial

VGL-100

Valve Guide Level

Instructions

Calibration of Levels

Levels can be calibrated even on a non-level surface:

After purchase of a new level or the installation of a

new vial, place level on a flat surface.  Adjust jam nuts

until you get bubble reading on the vial.  Rotate level

180 degrees and adjust 1/2 of difference out of bubble

reading.  Rotate level 180 degrees again, now bubble

should read exactly the same in both positions.  You

may need to repeat this process 2-3 times to fine tune

level.

If you can adjust surface that you just calibrated level

on, adjust it so the bubble reads center of the vial, then

rotate level 180° to prove level repeats (Bubble staying

in the center).

How to adjust the VGL-100 Valve Guide Level

This level is un-calibrated when you receive it. Your

first step is to level machine bed as close as possible (by

eye).  Set cylinder head in cradle with chamber side up.

Level by eye as close as possible.  Set new level on top

of valve guide pilot.  With level vial facing front to back

(position the end with 2 jam nuts facing you).  Adjust

level of head or level vial until you can get some sort of

bubble reading.  Rotate level 180°, just opposite of

where you started.  Read where bubble is exactly, now

rotate level back to its original position.  Noting the two

readings, adjust 1/2 of the difference of the two readings

out of the level itself by loosening and snugging the two

nuts on one end.

Even though the level may not read exactly in center it

is calibrated correctly when the readings 180° apart are

the same.

Double check this by rotating 90° from where you are

at. (Perpendicular to the previous placements).  Read the

bubble, then rotate 180° from this point, if level is cali-

brated, the bubble will repeat its  previous reading in the

new position.  (Readings 180° apart will be the same if

the level is calibrated.)

Now to center bubble in level, re-adjust cylinder head

and pilot so bubble reads center.  Then rotate level

through full circle (360°).  The bubble should remain at

center, if not, repeat calibration process.  (Remember

machine must be level to get your Level to read dead

center.) 

Even if you are 1/8 of a line space off after calibration

this will be close enough to install guides properly.

Reviewed June 2013

Reviews: