background image

Lynx Home S Series (HV)

User Manual

Ver 1.0

2021-3-15

Summary of Contents for Lynx Home LX S10-H

Page 1: ...Lynx Home S Series HV User Manual Ver 1 0 2021 3 15 ...

Page 2: ...ument complete accurate and up to date However GoodWe may need to make some improvements under certain circumstances without advance notice GoodWe shall not be responsible for any loss caused by this document including but not limited to omissions errors typographical errors arithmetical errors or listing errors in this document Disclaimer Version Date Record V1 0 2021 3 15 First Release Lmitation...

Page 3: ...5 1 Installation Environment 9 5 2 Installation Environment Requirement 9 5 3 Battery System Installation 10 5 4 Electrical Connection 13 5 4 1 Remove Cover of the Maintenance Compartment 13 5 4 2 Grounding Cable Connection 14 5 4 3 Power Cable Connection 15 5 4 4 Communication Cable Connection 17 06 Battery System Operation 20 6 1 Check Before Power ON 20 6 2 Power ON 20 6 3 Indicator Status 20 6...

Page 4: ...rbon dioxide extinguisher or Novac1230 or FM 200 is nearby Use recommended extinguisher when fighting fires water or ABC powder extinguisher is prohibited Firefighters are required to wear full protective clothing and self contained breathing apparatus The battery module may explode when the ambient temperature exceeds 150 Please use appropriate tools and take protective measures when installing a...

Page 5: ...k Pay attention to safety protection during installation operation and maintenance Grounding To indicate PE cable connection position This manual introduces Lynx Home S Series HV Battery System hereinafter referred to as the Battery System including the product introduction application installation commission maintenance and technical parameters etc The Battery System consists of the LX S2 5 H Bat...

Page 6: ...rows if there are 5 8 Battery Modules Ensure that the PCU is installed above the Battery Module Do not install any Battery Modules above the PCU This manual will show you the installation and cable connection of a Battery System consists of 8 Battery Modules First Row 4 9 10 3 2 1 5 6 7 8 10 Second Row No Parts 1 2 3 4 5 6 7 8 Battery Module 9 PCU 10 11 Upper Cover ...

Page 7: ...2 BAT 3 CAN COM Port Connected to the PCU the two ports works the same 4 Indicator 5 Grounding Point 6 BAT Cable Port 7 BAT Cable Port 8 COM Cable Port Indicator Status Green Light 1s on 1s off Normal Red Light Blinking 1s on 1s off Alarming Red and Green Light Blinking 1s red 1s green Faulty ...

Page 8: ...5 3 3 PCU Appearance 4 1 14 2 3 10 13 56 12 11 7 8 9 Front View Left View Right View ...

Page 9: ...M Cable Port To Battery Module 3 Power To Inverter 4 Power To Inverter 5 Power To Battery Module 6 Power To Battery Module 7 SOC Indicator 8 COM Cable Port 9 INV Cable Port 10 INV Cable Port 11 BAT Cable Port 12 BAT Cable Port 13 Grounding Point 14 Circuit Breaker ...

Page 10: ... if moisture penetrates ports Place the equipment in a cool place where away from direct sunlight Keep the equipment away from inflammable explosive and corrosive things Keep the equipment away from the rain The Battery System consists of the Battery Module the PCU and the accessory bag Check outer packing for damage and model before unpacking it If you find any damage or the model is not what you...

Page 11: ...wer Cable BAT HV x2 COM Cable BAT HV x1 Terminal Resistance x1 Power OT Terminal x4 PIN Terminal HV x4 Grounding Terminal x2 M5 Screw x6 Expansion Bolt x4 User Manual x1 Accessory Bag Upper Cover x1 Cover Bracket x2 Battery Bracket x2 M5 Screw x8 M4 Screw x4 N A N A N A ...

Page 12: ...The optimal working temperature for the Battery System is 20 40 Avoid exposing the equipment to direct sunlight or rain Install the equipment away from heat cold source Do not install the equipment in the place where the temperature changes extremely Install the equipment away from strong interferences Install the equipment far away from children Do not install the equipment in places prone to acc...

Page 13: ...acket 3 5 N M M5 Number stickers are pasted on the outer package of the Battery Module For example 1 1 1 2 1 3 1 7 are in the same group Check the number sticker on the package before unpacking to make sure that they are in the same group Battery Modules with number from different groups like 1 1 and 2 1 cannot be connected in one battery system ...

Page 14: ...Screw the expansion bolts to fix the Battery Module Tightening torque 10N m Install the battery bracket for the Battery Module at the bottom only Put the Battery Module cling to the wall and the bottom of the Battery Module cling to the ground Watch out Battery Modules dropping Shelter the equipment using paperboards when drilling to avoid dust 8 Repeat step 1 to step 7 to install the second third...

Page 15: ...lease refer to step 1 and 2 10 Install the locking bracket for the PCU Align the holes of the upper and the lower Battery Modules when placing the upper Battery Module At most 4 Battery Modules can be stacked in the single row 1 4 Battery Modules Installed 5 8 Battery Modules Installed 3 5 N M M5 ...

Page 16: ...he Circuit Breaker Cover of the PCU Shelter the equipment using paperboards when drilling to avoid dust Put the locking bracket cling to the wall and bottom of it cling to the Battery Module Watch out the PCU dropping 5 4 Electrical Connection 5 4 1 Remove Cover of the Maintenance Compartment 11 Put the PCU above the installed Battery Module securely Mark the drilling hole using a marker then remo...

Page 17: ...Disconnect the PE cable before dismantling the equipment The cross sectional area of the PE cable conductor 5mm2 The cable should meet standards for outdoor use The drawing force of the cable after crimping should be at least 400N All Battery Modules and power control units should be grounded separately L1 L2 L1 1 2mm 5 4 2 Grounding Cable Connection 3 5 N M M5 3 5 N M M5 ...

Page 18: ...when installing because there is no switch in a single Battery Module Power off the Battery System before connecting the power cable to avoid high voltage danger The drawing force of the power cable is at least 1200N after crimping Put the seal ring of the waterproof joint in the plastic ring Do not disassemble the seal cap if the waterproof joint is not connected to the cable The cross sectional ...

Page 19: ...ble 3 Thread the cable through the cable gland 2 Make the power cable used to connect Battery Modules Crimp the power OT terminal at both ends of the cable Connection Diagram of 1 4 Battery Modules Nut Nut BAT INV INV BAT BAT BAT 5 N M M6 4 N M Seals Seals ...

Page 20: ...ot disassemble the seal cap if the waterproof joint is not connected to the cable RJ45 Rejestered Jack 12345678 If there are 5 8 Battery Modules in the battery system the power cable between two rows of Battery Modules should be decided according to the actual situation The drawing force of the cable after crimping should be at least 1200N BAT BAT ...

Page 21: ...he communication cable Connection Diagram of 1 4 Battery Modules Battery COM Port PCU COM Port PIN Definition PIN Definition 1 CAN_H 4 CAN_H 2 CAN_L 5 CAN_L 3 4 24V 1 2 3 6 7 8 N A 5 6 GND N A N A 7 8 NC N A N A Nut BAT INV INV COM INV BAT BAT BAT 7 5 N M COM COM COM ...

Page 22: ... Module Connection Diagram of 5 8 Battery Modules If there are 5 8 Battery Modules in the Battery System the power cable between two rows of Battery Modules should be decided according to the actual situation 5 Install the decorative board of the Battery Module and the PCU ...

Page 23: ... 75 SOC 95 SOC 95 Normal Status Indicator No Items 1 The equipment is installed firmly in a place where is convenient for operation and maintenance The installation place is clean and well ventilated 2 The ground cable power cable communication cable and terminal resistance are connected correctly and securely 3 The cable ties meet the cabling requirements and are reasonably distributed No cables ...

Page 24: ...rt the battery if the problem persists for a long period Overcurrent Discharing Wait for 5 minutes Restart the battery if the problem persists for a long period LMU Communication Fault Restart the battery If the problem persists please contact the After sales service Temperature Sensor Broken Inverter Communication Fault Check the communication cables between the battery and the inverter Shutdown ...

Page 25: ...ttery Module and the inverter Set battery model via PV Master APP Battery Communication Failure will be displayed if you select the wrong battery model Please select the right battery model accordingly otherwise the equipment cannnot be used normally Download and install PV Master Connect your smartphone and the inverter Wi Fi SSID Solar WiFi Password 12345678 LX S H APP installation and connectio...

Page 26: ... of the PCU The ground cable power cable and communication cable are connected correctly and securely The cable ties meet the cabling requirements and are reasonably distributed Also the ties are tightly tied without sharp corners Place the inverter in a reasonable space where is clean tidy and no construction debris Install the cover of the Battery Module Install the cover of the PCU ...

Page 27: ... 4 Install the bracket on the Battery Module and the PCU using M5 screws torque 3 5N m 5 Install the cover on the Battery Module and the PCU using M4 screws torque 1 6N m 3 Do not extrude the cables when installing the decorative board ...

Page 28: ...384 460 8 V Weight 126kg 163kg 200 kg 237 kg 274 kg 311 kg Dimensions W D H 610 226 1170 mm 610 226 1445 mm 1220 226 1445 mm Depth of Discharge DOD 90 Max Charge Discharge Current 50A 1C Rated Power 7 68 kW 10 24 kW 12 80 kW 15 36 kW 17 92 kW 20 48 kW Communication CAN Operating Temperature Charge 0 50 Discharge 20 50 Humidity 90 Operating Altitude 2000m Protection Degree IP65 Outdoor Indoor Insta...

Page 29: ...hether there is debris accumulation around the Battery Module to avoid affecting heat dissipation Once Every 6 months Check for water and pest to avoid prolonged intrusion Once Every 6 months Please contact After sales Service for help if you find any problems that may influence the Battery Module or the inverter Disassemble without permission is strictly forbidden Please contact after sales for h...

Page 30: ...l are equispaced rectangular distribution Required torque for plastic expansion screw 10 10 N m The floor must be horizontal when drilling holes in a stacking way The paperboards have to be placed cling to the ground and avoid longitudinal tilt Paperboard Bottom ...

Page 31: ... POWER SUPPLY TECHNOLOGY CO LTD No 90 Zijin Rd New District Suzhou 215011 China www goodwe com service goodwe com PV Master APP SEMS Portal APP SEMS Portal website www semsportal com LinkedIn Company s offical website ...