3A0978A
Instructions
Gear/Drive Kit for Magnum X5, X7,
LTS 15, LTS 17 (Series B)
This manual contains kit installation instructions only
Kit: 16E778, 16E835
Pressure Relief Procedure
Important Safety Instructions
For detailed sprayer information and warnings,
see Operation manual 312001, 313034.
To help prevent injection injuries, follow this procedure
when you stop spraying and before you service or clean
the sprayer, remove parts, or repair leaks.
1.
Turn Power switch OFF. Unplug sprayer.
2.
Turn Spray/Prime valve to PRIME to relieve pressure. Turn
pressure control knob left (counterclockwise) to minimize
pressure.
3.
Trigger gun.
4.
Put trigger safety in safety ON position.
NOTE: Leave Spray/Prime valve in PRIME
position until you are ready to spray again.
If you suspect that the spray tip or hose is completely clogged or
that pressure has not been fully relieved after following the steps
above, VERY SLOWLY loosen the tip guard retaining nut or hose
end coupling to relieve pressure gradually. Then loosen it com-
pletely. Clear the tip or hose obstruction.
ti15766a
ti11868a
ENG