www.graco.be
ULTRA
®
MAX II - MARK V
™
Premium & Platinum
MARK X
™
SETUP
Connect hose to sprayer and gun.
Tighten hose connections with wrench.
Unscrew tip & guard from gun.
Fill throat packing nut with TSL
™
to prevent premature packing wear.
Make sure power
switch is set to OFF.
Plug electrical cord
into grounded outlet.
Turn prime valve
to Prime position (down).
Place siphon tube in pail
partially filled with water.
Turn pressure control knob to
lowest pressure (platinum range
only), and set power switch to ON.
Increase pressure until
sprayer starts and water
runs out of prime tube.
Let water run out of
prime tube for 15 seconds.
Decrease pressure until
sprayer stops. Make sure
you are not in E-Control*
mode. (*platinum range only).
Turn prime valve
to Spray position
(horizontal).
Make sure safety
lever of gun is OFF.
Aim gun at inside
wall of water pail
and squeeze trigger.
Increase pressure
until sprayer starts.
Keep gun triggered into
water pail for 1 minute.
Release trigger.
Turn prime
valve to Prime
position (down).
Place siphon tube in paint
pail, but leave drain tube
in water pail.
Aim gun at inside
wall of water pail,
and squeeze trigger.
Transfer drain
tube to paint pail.
Increase pressure until
sprayer starts and paint
comes out of drain tube.
Keeping gun triggered into
water pail, turn prime valve
to Spray position (horizontal).
When paint comes out of gun,
release trigger and turn safety
lever of gun to ON.
Screw tip & guard onto gun, making sure
arrow-shaped handle of tip is pointing forward.
You can reverse this tip to quickly clear clogs
without taking it apart.
WATCHDOG
™
(Ultra
®
Max II range only)
This procedure is for water-base paints and flushing fluids. For solvent-base paints and flushing
fluids (i.e. mineral spirits), you must read Fire and Explosion Hazard in the Operating Instructions.
* check the Graco operations manual delivered with the unit for more details.
OPTIONS
WARNING
Quick Operator’s Guide
Empty displays/flashes and pump stops when WatchDog
protection system detects an empty material pail.
Turn WatchDog switch OFF. Add material or reprime sprayer.
Turn pump switch OFF and ON to reset WatchDog protection system.
Turn WatchDog switch ON
and WatchDog ON displays.
Set pressure high enough to spray. The E-Control
acts in place of the pressure control knob when
the sprayer is in E-Control mode.
Press the E-Control UP or DOWN
to increase or decrease the stall
pressure setting by 3 bar.
If the stall pressure reaches
the limit in either direction
the sprayer beeps 3 times.
If the E-Control UP or DOWN is pressed
and held, the stall pressure will change
to maximum sprayer setting or 0 bar.
E-Control
™
(platinum range only)