background image

1

 

Grand Canyon Gas Logs---3435 E. Atlanta Ave---Phoenix, AZ 85040 

 

 

 

 

INSTALLATION AND OPERATIONS GUIDE FOR 

GRAND CANYON GAS LOG SYSTEMS 

 
 

 
Grand Canyon Gas Logs, logs are made of cement refractory material re-enforced with steel fibers.  Each of the logs are hand painted and 
hand finished to recreate the most realistic logs available on the market.  The gas burner system is designed to recreate and burn like a real 
wood burning fireplace with a natural looking flame.  With this in mind the gas log sets MUST be burned in a fully vented, non-combustible 
fireplace with the DAMPER COMPLETELY OPEN and the chimney free of any obstruction or restrictions.  The fireplace must be designed and 
approved to bur wood.   
The realistic flame produced by Grand Canyon Gas Log burners produce carbon monoxide and soot.  Under standard conditions these 
byproducts are exhausted up the chimney.  IF the fumes or soot from the burning gas are evident in the room when the damper is fully open 
it indicates that the fireplace draft is defective.  IF this happens DO NOT operate your gas logs until the fireplace drat is corrected, call a 
service technician to fix the problem. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Installation and service must be provided by a qualified installer, service agency or 

gas supplier 

WARNING: If the information in this 
manual is not followed exactly, a fire or 
explosion may result, causing property 
damage, personal injury or loss of life 

 

-

 

Do not store or use gasoline or other 
flammable vapors and liquids in the 
vicinity of this or any application 
 

WHAT TO DO IF YOU SMELL GAS 
 

 

Do not try to light any appliance 

 

Do not touch any electrical switch; 
do not use any phone in the building 

 

Immediately call the gas supplier 

from a neighbor’s phone.  Follow 
the gas supplier’s instructions

 

 

If you cannot reach the gas supplier, 
call the fire department. 

-

 

Installation and service must be 
performed by a qualified installer, 
service agency or the gas supplier 

 

Grand Canyon Gas Log sets are to be installed only in a solid-
fuel burning fireplace with working flue and construction of 
noncombustible material.  The installation including 
provisions for combustion and ventilation air must conform 
with the 

National Fuel Gas Code

, ANSI Z223.1/NFPA 54, or 

the CSA B149.1 Natural Gas and Propane Installation Code, 
and applicable local building codes.   
A damper clamp is included to maintain the minimum 
permanent vent opening and to prevent full closure of the 
damper blade.  The chimney damper must be fully opened 
when burning the log set. The log set is designed to burn 
with a yellow flame, thus adequate ventilation is absolutely 
necessary.   
To comply with certifications, listings, and building code 
acceptances, and for safe operation and proper 
performance of this log set, use only Grand Canyon Gas Logs 
parts and accessories.  Use of other controls, parts, and 
accessories that are not designed for use with Grand Canyon 
Gas Logs log set is prohibited and will void all the 
warranties, certifications, listings and building code 
approvals, and may cause property damage, personal injury 
or loss of life.   

WARRANTY 

Grand Canyon Gas Logs burners and logs carry a 
lifetime warranty against breakage and defects to the 
original purchaser.  ALL GCGL valves, pilot assemblies 
and electrical components carry a 2 year warranty as 
long as installed indoors and installed by a licensed 
professional.  Further warranty information can be 
found in the warranty section of this guide.   

 

INSTALLER: Leave this manual with the log set 
CONSUMER:

 

Retain this manual for future reference.   

Burner Systems: 

GLASSBRN-18 
GLASSBRN-24 
GLASSBRN-30 
GLASSBRN-36 

 

Summary of Contents for GLASSBRN-18

Page 1: ...m a neighbor s phone Follow the gas supplier s instructions If you cannot reach the gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Grand Canyon Gas Log sets are to be installed only in a solid fuel burning fireplace with working flue and construction of noncombustible material The installation including p...

Page 2: ...e appliance is operating and unless other provisions for combustion air are provided the screen shall have an opening s for introduction of combustion air With use of glass doors doors must be open while the appliance is burning to assure proper ventilation 7 The minimum inlet supply pressure for the purpose of input adjustment is 5 0 inches natural gas 8 0 inches propane in water column The maxim...

Page 3: ...3 Grand Canyon Gas Logs 3435 E Atlanta Ave Phoenix AZ 85040 MINIMUM CHIMNEY HEIGHT AND FLUE OPENING ...

Page 4: ... length of time will cause the logs to soot Soot only accumulates on the log therefore the burner will not need cleaning Soot is caused be incomplete combustion of the gas leaving behind a dark dense material Soot will also accumulate on the logs if the logs are not placed in the proper position according to the log placement diagrams To clean off soot use an old tooth brush and gently rub away th...

Page 5: ...make sure the stud does not turn loosening the connection inside the wall 3 Center the burner from side to side and position it as close to the back wall of the firebox Ideally the burner will be aligned directly under the flue damper 4 Use the 3 8 aluminum flex line connector to connect the gas supply line to the gas inlet on the valve When bending the aluminum flex line use proper bending proced...

Page 6: ...and to replace any part of the control system and any gas control which has been underwater LIGHTING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 3 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow ...

Page 7: ...0 Heat Shield 4 110 3 8 Flare x 3 8 Adaptor 5 401 3 8 x Male 6 120 PB Mounting Bracket 7 426 3 8 x 3 Swivel Nut 8 660 Parts Bag 9 102 Pilot Assembly 10 101 Stem 11 229 10 Black Flex line Not Shown SPLPK 1 Vermiculite 2 460 Air Mixer Orifice 3 218P LP Orifice VALVE PARTS LIST 1 8 7 2 3 9 4 10 5 6 1 2 3 ...

Page 8: ...ment will be available for pick up from the dealer at which the burner was originally purchased Burners installed outside carry a 1 year warranty This warranty is limited to original purchaser only Electrical and Valves Grand Canyon Gas Logs valves pilot assemblies and electrical components carry a 2 year warranty against breakage or defects from date of purchase by original purchaser and must be ...

Reviews: