background image

MA

NU

EL 

DU

 P

RO

PR

IÉT

AIR

E

Dés

hum

id

ific

ate

ur

Mod

èle

s :

GD

N50

AP

-A

3E

BA

1A

GD

N70

AP

-A

3E

BA

1B

Mer

ci d

’av

oir 

cho

isi

 no

tre

 p

rod

uit.

S.v

.p

.  L

ire

 at

ten

tiv

em

ent

 ce

 m

anu

el a

van

t l’

util

isa

tio

n e

t g

ard

ez-

le 

pou

r

réf

ére

nce

s.

007

54_

09/

/05

/20

16

Cod

e G

REE

 : 1

3-0

609

4/0

95

OWNER’S MANUAL

Dehumidifier

Model:

GDN50AP-A3EBA1A
GDN70AP-A3EBA1B

Thank you for choosing our product. For proper operation, please read this
manual carefully and keep it for future reference.

00754_09//05/2016

Code GREE : 13-06094/095

© T

ous

 dr

oits

 ré

ser

vés

, G

REE

 C

ana

da,

 20

16

© Copyright, GREE Canada, 2016

00754_Owner'

s manual 

Dehumidifier50/

70 Pint

s_Mise en 

page 1 

 16-05-09 

 08:

58  Page1

Summary of Contents for GDN50AP-A3EBA1A

Page 1: ...er Model GDN50AP A3EBA1A GDN70AP A3EBA1B Thank you for choosing our product For proper operation please read this manual carefully and keep it for future reference 00754_09 05 2016 Code GREE 13 06094 095 Copyright GREE Canada 2016 ...

Page 2: ... Check Before Operation 4 OPERATION INSTRUCTIONS Operation Method 5 Drainage Option 8 MAINTENANCE Cleaning and Maintenance 10 MALFUNCTION Troubleshooting 12 Malfunction Codes 14 Warranty 15 Note The images in this manual are only for reference Please refer to actual products for specific details ...

Page 3: ...the dehumidifier in an area where the temperature will not go below 5 C or above 32 C Allow at least 30 45 cm of air space on all sides of the unit Close all doors windows and other openings in the room to improve the effect of the humidifier Please keep the air inlet outlet clean and unobstructed Do not use a dehumidifier in a bathroom Avoid direct sunlight 30 45cm 30 45cm Correct The dehumidifie...

Page 4: ... The memory function is included in this dehumidifier When the unit is not in use please turn it off and remove the power plug or disconnect the power Do not repair or disassemble the unit yourself A damaged power cord must be replaced by a qualified technician or manufacturer If an abnormal condition occurs e g burned smell please disconnect the power at once and then contact local dealer This de...

Page 5: ...3 PARTS Front side Back Side ON LIGHT WATER BUCKET AIR FILTER POWER PLUG CONTROL PANEL FRONT GRILL ROLLER ...

Page 6: ...es on both sides of the water bucket and pull out in the direction indicated by the arrows 2 Check that the float in the water bucket is properly placed It may have shifted during transportation If it s not placed properly move it to the correct position by hand 3 Replace the bucket as instructed in step 1 Correct Position Float Wrong Position ...

Page 7: ...he section Drainage method Whenever a button on the control panel is pressed a beep will sound When the power is connected the power indicator on the control panel will turn on at the same time the dehumidifier emits a beep POWER Button Press this button to turn the dehumidifier on or off Button In the free drying mode press these buttons to set humidity Invalid under other modes Pressing the butt...

Page 8: ...1h When the time is set wait for 5s or press this button to turn this function on The timing Indicator will turn on Cancel Timer Off Under the condition that this function is turned on press this button to cancel it The timing Indicator will turn off Set Timer On When the unit is off press this button and the Timer Indicator will turn on while the display window will show the time Each press of th...

Page 9: ...t is full removed or not placed correctly or the humidity is 5 lower than the set humidity the unit will automatically stop 3 Memory Function If power is lost all of the control settings are remembered So when power is restored the unit will start back up in the settings it was in when the power was lost 4 Bucket full light This indicates that the bucket is full removed or not placed correctly 5 C...

Page 10: ...of into the bucket 1 Hold the handles on both sides of the water bucket and pull it out in the direction indicated by the arrows Attention Pull out the bucket carefully to prevent the water from spilling out of the bucket and onto the floor 2 Empty the bucket by grasping the handle on the top of bucket with one hand and the bottom of bucket with the other hand 3 Replace the bucket in the dehumidif...

Page 11: ...e bucket from the unit as instructed 3 Thread the drain hose onto the nozzle and make sure it s securely locked 4 Replace the bucket Make sure the drain hose goes through the bucket s drain hole and is placed downward Feed the hose into the floor drain and then cover the hole with a lid Note that the drain hose should not be compressed the water cannot drain Note When you want to take off the drai...

Page 12: ...using is very dirty greasy use mild detergent to clean it To clean the grill Use a duster or brush 2 Water Bucket Every few weeks clean the bucket to prevent the growth of mold mildew and bacteria Use a soft brush to clean the bucket and then rinse it To remove 1 The rotor shaft on the handle toward the hole of buckle plate Pull the bucket plate on the handle side in the direction indicated by the...

Page 13: ...rwise the evaporator will catch dust and affect the unit s performance Do not dry the air filter with heat or an electric hair dryer Otherwise the air filter may be misshapen or catch on fire ally Check whether the air outlet is blocked Check whether the power plug and power socket are in good condition Check whether the air filter is clean Check whether the drain hose is damaged Disconnect power ...

Page 14: ... the sound of the flow of refrigerant There might be some noise if unit is operating on a wooden floor Due to increased temperature of heat exchanger the air may smell strangely at the beginning Room temperature is too low Humidity level may be improperly set If unit is operating in a room where tempera ture is from 5 to 15 C it will start to defrost automatically Compressor will stop for a brief ...

Page 15: ...w Warm temperatures are good for dehumidification Low temperatures will reduce unit s effect This unit should be used in a place where temperature is above 5 C Make sure all doors and windows and other openings to the outside have been closed Clean the filter Make sure there is no curtain shutter or furniture blocking the dehumidifier If you want the air drier press to lower the number or press th...

Page 16: ...e terminal of display board An element of display board may have been put in upside down and caused short circuit Ambient temperature sensor is damaged Please refer to Checking Table for Temperature Sensor Resistance Temperature sensor on the evaporator is loose or is poorly connected to the terminal of display board An element of display board may have been put in upside down and caused short cir...

Page 17: ...ring or failure to follow the operating and maintenance instructions provided in this ownerʼs manual 3 Damage to the finish of the unit housing or to other outer features caused by wear 4 The filter 5 Damage caused by repairs or modifications to the humidifier made by any person not duly authorized by GREE 6 Insurance and freight costs for the warranty service ALL IMPLIED WARRANTIES INCLUDING ANY ...

Page 18: ... ...

Reviews: