background image

OWNER’S

MANUAL

Indoor Unit

CONS09HP230V1AF
CONS12HP230V1AF
CONS18HP230V1AF

MODELS:

CAT NO:GREE_MINI-FLOOR CONSOLE

 

A_OWNERS_11102022

Thank you for choosing our product.
Please read this Owner’s Manual carefully before
operation and retain it for future reference.

To download an electric version of this manual visit 

https://gree-comfort-dev.web.app/system-documentation/

 

Summary of Contents for Mini-Floor Console A Series

Page 1: ... CAT NO GREE_MINI FLOOR CONSOLE A_OWNERS_11102022 Thank you for choosing our product Please read this Owner s Manual carefully before operation and retain it for future reference To download an electric version of this manual visit https gree comfort dev web app system documentation ...

Page 2: ...nto millions of other GREE installed products worldwide has gone into your unit Please read this owner s manual carefully before operation and retain it for future reference TABLE OF CONTENTS Nomenclature 3 Safety Precautions 4 Part Names 6 System Functions 7 Operation of Remote Contoller 9 Care and cleaning 14 Troubleshooting 15 Energy Saving Tips 16 Warranty 17 Owner s manual FAQ ...

Page 3: ... Level Electrical Rating 230V 208 230V 1PH 60Hz Style Color Designation Product Type O Outdoor Units C Indoor Cassette D Indoor Slim Duct F Consoles Floor only Model Type HP Heat Pump Capacity 09 9 000 BTUH 12 12 000 BTUH 18 18 000 BTUH Series Designation CAS Cassette DUCT Slim Duct FLR Floor Ceiling CONS Mini Floor Console ...

Page 4: ... in enhanced installation reliability or operation NOTE Your actual air conditioning heating system and related devices may differ from the images shown in this manual WARNING This appliance is not intended for use by children without responsible adult supervision Proper care should be taken to ensure safety WARNING Heat pumps air conditioners heating equipment should be installed started up and s...

Page 5: ...leaning be careful not to splash water on the unit Doing this may cause electric shock or damage to unit Do not use or place any flammable combustible or noxious substance next to the unit In the event of a failure burning smell etc immediately disconnect all electrical power to indoor and outdoor units Never try repairing the system yourself contact a qualified service technician for all repairs ...

Page 6: ...shall be installed in accordance with national wiring regulations NOTE 16 Air outlet selection switch This setting blows air from upper outlet only This setting automatically decides a blow pattern depending on mode and conditions The unit is shipped from the factory with this setting This setting is recommended 1 Titanium Apatite Photocatalytic Air Purifying Filter 12 Run lamp 13 LED display 16 A...

Page 7: ...controller instead of at the indoor unit It then adjusts airflow and temperature accordingly for ultimate personal comfort ADJUSTABLE AIRFLOW The adjustable swing louvers can be controlled from the remote controller Vertical swing louvers allows five different air discharge directions including Continuous Sweep Maximize comfort by adjusting the direction of airflow in the room by moving the louver...

Page 8: ...ons are no problem for the Mini Floor Console A User selections and system parameters are stored in non volatile memory These parameters are retained during a power failure When power is returned the Mini Floor Console A Series system will automatically return to the last operating mode INTELLIGENT DEFROST The Intelligent Defrost function increases room comfort and saves energy by eliminating unne...

Page 9: ...SOLE A SERIES OWNERS MANUAL INDOOR UNIT 9 OPERATION OF REMOTE CONTROLLER Buttons on remote controller Introduction for icons on display screen Remote lock out DISCLAIMER All functions are not available for this unit ...

Page 10: ...ting FAN the unit will operate in a fan only mode no heating or cooling and all indicators will be off When all indicators are off press FAN button to adjust fan speed Press button to adjust fan blowing angle When selecting HEAT the air conditioner operates under heat mode Press or button to adjust set temperature Press FAN button to adjust fan speed Press button to adjust fan blowing angle NOTE W...

Page 11: ...ill automatically swing up down at maximum angle Select and fan modulation will stop at that fixed position Horizontal louver will stop at the fixed position Select will not modulate but blow at a fixed angle Hold button more than 2s to set your required swing angle When reaching your desired angle release the button NOTE Pressing this button continuously for more than 2s the louver will swing bac...

Page 12: ...played on the remote controller When set the remote controller will send the detected ambient temperature to the controller and the unit will automatically adjust the indoor temperature according to the detected temperature Press this button again to cancel I FEEL function and will disappear Put the remote controller near the user when this function is set Avoid putting the remote controller near ...

Page 13: ...sted TURBO will not work either Sleep function and 46 F 8 C heating function can t operate at the same time If 46 F 8 C heating function has been set under heat mode pressing the SLEEP button will cancel 46 F 8 C heating function If sleep function has been set under heat mode initiating the 46 F 8 C heating function will cancel SLEEP function Remote lock out Press or simultaneously to turn on or t...

Page 14: ...ont panel Remove the string Allowing the front panel to fall forward will enable you to remove it 3 Clean the front panel Wipe it with a soft cloth soaked in water Only neutral detergent may be used In case of washing the front panel with water dryit with cloth dryit up in the shade after washing 4 Attach the front panel Insert the front panel into the grooves of the unit 3places Attachthestringto...

Page 15: ...ned on the HEAT mode In order to prevent cold air from blowing out it may take several minutes before the fan starts This is normal Air conditioner isn t coming on Power failure Wait until power recovery Loose wiring Contact your contractor or an electrician Circuit breaker has tripped or fuse is burnt out Ask professional to replace circuit breaker or fuse Wiring is overheating or needs repair As...

Page 16: ...s grass clippings and other debris can stick to coil fins and make the unit work up to 15 harder 5 Rearrange the room Furniture that obstructs the airflow needs to be removed or rearranged accordingly 6 Try 75 degrees 75 F is a good point for an air conditioner to run at its optimal performance level Even a 5 degree change in temperature can make your unit use up to 40 more energy 7 Lighting Turni...

Page 17: ...___________________________ Serial No ___________________________________ Outdoor Model No _____________________________ Serial No ___________________________________ Owner Name _________________________________ Date of Installation ___________________________ Address of Installation Installing Contractor ____________________________________________________ Address ________________________________...

Page 18: ...U S CONTACT INFORMATION TRADEWINDS LLC E mail info twciimate com Contractor Support 888 850 7928 I Mon Fri 8 AM 5 PM EST G R E E C O M F O R T C O M ...

Reviews: