background image

Owner's Manual 

Operation Instructions 

1. LED indicator and seven-segment digital display

 

Connect the charger to the battery. Turn on the mains. The charger enters the charging mode (the battery type indicator shows the default battery 
type). The status indicator - % Percent, Battery Voltage, Charging Current and the seven-segment digital display will show the charging status.

 

Maintenance Instructions 

1.

Do not expose charger to oil, dirt, mud or direct heavy water spray when cleaning vehicle.

2.

The enclosure of the charges has been tested successfully to IEC 60529, meeting IP66

 or IP67 (see silk screen of 

the device

).

3.

If the detachable input power supply cord set is damaged, replace with a cord that is a safety approved detachable cord, 3 conductor, 1.5 

mm² minimum, and rated appropriate for use in the country of destination and, on the other end, an output grounding type IEC 60320 C14 plug. 

Product Specifications 

% Percent: 

Battery capacity % indicator. i.e. 10, 20, 30…… 100 (%) 

Battery Voltage (V)

: Battery voltage indicator. i.e. 24.0(V) 

Charging Current (A): 

Charging current indicator. i.e.15 (A)

 

Model 

GPCC1524 

DC Output 

Voltage-Range(V) 

0-34V 

Current-Range(V) 

0-15A 

Output Power(W) 

510W 

Power Error(%) 

1% 

Applicable to Battery 

AGM, WET, GEL, Lithium 

Reverse Polarity 

Electronic protection-auto-reset 

Short Circuit 

Electronic protection-auto-reset 

AC Input 

Voltage-Range(V) 

100-240V 

Frequency(Hz) 

50-60Hz 

Current-max(A) 

5

Full Load AC Power Factor 

>0.98

Dimensions 

22.6

*15.2*8.1cm 

Weight 

2.5KG 

Operating Temperature 

-40

~+65

℃ 

Storage Temperature 

-40

~+70

℃ 

3. 

Status indicator and seven-segment digital display: 

4. 

The instruction for cable connection:

1 Connect the battery. 

2 Interlock Cable (When charger is charging, the interlock 

cables will form an open circuit with no voltage. When charger is not charging, the 

interlock cable will form a short circuit with no voltage).

 

3

 

Connect AC input wires.    

4  Connect CANBUS or LED light wire (Optional function)    

Warning: 

Assure the battery connection cable is

 

well connected with the charger before it is connected to the battery. Otherwise, the 

battery short circuit may occur and cause personal injury or damage to the battery.

 

 

Seven-segment

 digital display

fault code  Fault Cause 

Solution 

E01 

The battery is not well connected 
or battery reversely connected or 
battery damaged. 

1)

Check battery connection is correct. 

2)

Check charger connection is correct. 

3)

Check each battery is good..

E02 

Abnormal AC Power Input (Voltage). 

1)

Check AC input cord is connected between charger and AC outlet. 

2)

Make sure AC plug is tightly inserted into AC outlet.

E03 

Charger High Temperature 
Protection. 

1)

Charger shuts down and enters protection mode due to charger/environmental

temperature is too high. Please place the charger in a well-ventilated environment. 

2)

Disconnect the charger and wait for 15-20mins before reconnecting for charging.

E04 

Battery High 
Temperature Protection. 

1) Charger will reduce current even stop charging to prevent the battery from 

overheating when battery temperature exceeds the preset value. 

2) When the battery temperature drops, the charger will restart automatically.

E05 

1)

Discharging activities during charging

 

cycle. 

2)

Battery low voltage detected during

 

charging 

cycle. 

3)

Output current is too high 

(E05 will reappear even after unit reset). 

1)

Make sure no discharging activity during chargingoperation. 

2)

Reset charger (disconnect AC power and reconnect for a 2nd charge cycle). 

3)

If E05 reappear within 10 minutes, please return charger to factory for repairing.

E06 

Battery Voltage is too high.

 

Check and assure that the correct output battery voltage is connected.

E07 

Address declaration failure

Return to the factory for repairing. 

E08 

Internal error in product.

Return to the factory for repairing. 

E10 

Relay Fault

Return to the factory for repairing. 

E11 

Battery error (battery damaged or 

battery system error)

Replace battery 

Fault Indicator

 

2

INTERLOCK

 

1

。  

4

3

DC

 OUTPUT    

CANBUS/LED   AC INPUT

 

Powering 

everyday 

everywhere! 

%

v

A

Press 

5  s:  Change charging profile 

10 s:  Start EQ mode (Wet Battery) 

Battery capacity % indicator 
Battery voltage indicator

 

To change the charging profile, press & hold the Select button

 

for 5

 

seconds, then press the Select button to choose the

 

desired profile. Once selected, press & hold the Select key for 

5 seconds, and the charging profile selection will be completed. 

To start EQ mode, press & hold the Select button for 10

 

seconds, and display will show EQ mode. The next charging

 

cycle will go  into EQ

 

mode. If you want to quit the EQ mode, 

hold the Select button for 10 seconds. When display shows 

OFF, the charger will quit the EQ mode. 

Note:

 Each operation interval is 5 seconds. If the operation 

interval exceeds 5 seconds, it will automatically return to the 
default setting.

2.

 

Common Mode(Default) & BMS Mode

Select button  Charging current  indicator 

a. The charger enters BMS mode when being connected to lithium-ion battery through Can Bus; 
b. For safety reason, the charger will flash "bnS" if being reconnected to Lead-acid battery under a BMS mode; 
c. Press & hold the Select button for 3 seconds in BMS mode to release the curve number, that is, switch back to normal mode.Press &  hold 
the Select button for 1 seconds to choose the desired profile. 

GPCC1

7

24 

0-34V 
0-1

7

5

78

GPCC

3012

0-

17

0-

30

5

10

Summary of Contents for GPCC1524

Page 1: ...htly inserted into AC outlet E03 Charger High Temperature Protection 1 Charger shuts down and enters protection mode due to charger environmental temperature is too high Please place the charger in a well ventilated environment 2 Disconnect the charger and wait for 15 20mins before reconnecting for charging E04 Battery High Temperature Protection 1 Charger will reduce current even stop charging to...

Page 2: ...S LED AC输入 数码显示 三 故障显示 错误代码 故障原因 排除办法 E01 输出没接电池或接反 短路 坏节 1 检查电池组是否连接正确 2 检查稳压电源是否连接正确 3 检查电池组中的单个电池是否损坏 E02 市电不正常 电压 1 检查 AC 电源线是否连接在稳压电源和 AC 插座之间 2 确保 AC 插头紧插在 AC 插座上无松动 E03 稳压电源高温保护 1 稳压电源内部或环境温度过高 稳压电源将关闭并进入高温保 护模 式 请把稳压电源放在通风良好的环境工作 2 断开稳压电源 等 15 20 分钟后再重新连接稳压电源 E04 电池高温保护 1 当电池温度超过预设值后 稳压电源会关闭输出 防止电池继续过热 2 当电池温度下降后 稳压电源会自动重启 E05 1 充电过程中放电 2 充电过程中 电池电压太低 3 输出电流太高 在重启机 器后 E05 仍出现 1 在充电过程中 确定没有...

Page 3: ...4 Fullriver DC55 12 145 NBA 4GL12N 146 Discover EV12A A 147 Discover EV12A B 148 VISION EV24 85A AM 158 超威 6 EVF 100 159 山东圣阳 6 EV 100 163 SAMSUNG INR18650 167 US Battery US 31DC XC2 174 QUIMO QM 80 130 181 嘉得力锂电池 TB24100F T110C 184 理士 DJM12120 185 XUPAI 旭派 6 EVF 75 186 LUMINOR LDC12 80 187 LUMINOR LDC12 100 188 Zenith ZL120185 191 US Battery 24DC XC2 194 LUMINOR 24XMP 210 RoyPow S2480 8S1P REV E ...

Reviews: