No.4
Backcheck
No.1 Closing
No.2 Latching
90°
1
2
3
4
Fast Slow
Adjusting the force
No.3 Delayed Action
Using the templates provided, mark and
drill pilot holes into the door and frame.
Attach the armset to the mechanism ensuring the
pre-loading requirement has been completed.
Using the templates provided, fix the mechanism to the door
as well as the armset and any necessary brackets.
Operate door closer in order to check operation.
No.2
No.1
No.3
No.4
65
°
Regular Fixing
Installation and Maintenance Instructions:
Maintenance
1.Once the unit has been correctly
fitted it is recommended that
periodic checks (every six
months) are carried out to ensure
all fixings are tight and the door
closes freely and positively into
the frame, without slamming.
2.A light oil lubricant (non-graphite)
should be applied to the moving
joints and exposed pivot points.
After Installation
1.When the closer operates to close
the door from its maximum opening
position, it should ensure the lock
latchbolt and any seals are overcome
and the leaf returned into its frame.
2.When the door is slightly open and
the latch bolt resting against the
strike, release the door to ensure the
leaf fully closes into its frame.
Warning
1.Please note the minimum power size requirement for fire / smoke
door assemblies is 3 as required by Approved Document B.
2.Do not install mechanical hold open devices on fire / smoke door
assemblies.
3.Take care not to exceed the maximum opening angle as detailed
above.
4.Care and attention must be taken when adjusting any of the units
control valves to avoid damage through over adjustment.
5.All our Door Closer units are sealed for life and the internal
components assembled under high load, therefore, tampering
with the mechanism is to be strictly avoided.
Installation Instructions: Please refer to actual size template for exact fitting dimensions
Pre-Loading of Arm
For the unit to provide the optimum performance and overcome any resistance
upon closing it is recommended that the armset is “pre-loaded” To pre-load,
reposition the fixing angle of the arm onto the mechanism so that the end of the
closing cycle would be past the stop position, as indicated below.
Adjustment Details
This unit is a power adjustable mechanism. Power / force adjustment is carried
out by a single adjustment valve in the end of the mechanism. The unit is
pre-set in the factory at EN size 3. Please see table below for adjustment
details for each power size.
The following adjustment valves have a maximum adjustment of 1 full turn per
valve.
PLEASE NOTE
over adjustment will damage the mechanism and/or the
performance of the door closer and invalidate its guarantee.
Adjust Backcheck (valve #4) and the Delayed Action (valve #3) before
adjusting the Closing Speed (valve #1) and Latching Action (valve #2).
90°
90°
Before
After
Backcheck Adjustment
To increase the backcheck action, turn the valve clockwise. To decrease, or to turn
off backcheck, turn the valve counter clockwise.
Adjust the Closing & Latching speed.
1.The door closer can control two different speeds.
2.The No.1 speed-adjusting valve controls the Closing speed, and the No.2 speed
adjusting valve controls the Latching speed.
Delayed Action
To delay the closing action of the unit adjust valve No.3
ISSUE 02:08/17
10608 ZINS-F1128-9Z
www.gu-secury.com
Fixing Instructions for : L-10002-04
Door Closer Power Selectable EN 2-5
APPROVED
PRODUCT
CF 5514
CPR
AD5326
1121
17
BS EN1154:1997+ A1:2002
4 8 52 1 1 4
www.gu-secury.com
Fixing in Fig.1 / Fig.61
3
Max.
Door width
Max.
Door weight
950mm
60Kg
Power
size
180°
180°
Door opening
Max.
4
1100mm
80Kg
5
1250mm
100Kg
180°
8CCW
0
Number of turns
7CW
Factory preset
CW:Clockwise CCW:Counterclockwise
2
180°
850mm
40Kg
8CCW