background image

Shine Pano

Summary of Contents for Shine Pano

Page 1: ...Shine Pano...

Page 2: ...on Environmental Conditions 3 2 Installation Methods of Shine Pano 3 3 Connection with PV Devices 3 4 Connection with Network Device 4 1 Shine Pano Setting as a Terminal Display 4 2 Shine Pano Setting...

Page 3: ...Control 7 3 Manage Active and Reactive Power Simultaneously 7 4 PV Power Station Solution 8 1 Shine Pano firmware upgrade 8 2 Factory Default 8 3 Troubleshooting Shine Pano datasheet 6 7 8 9 Contact...

Page 4: ...any damages including indirect incidental or consequential damages caused by reliance on the material presented Distinguished users thank you very much for your trust in our Shine Pano product which...

Page 5: ...may be transmitted in any form without the prior written permission of our internal staff The content of manual could be changed Every attempt has been made to make this document complete accurate and...

Page 6: ...ance of Shine Pano is shown below Friendly user interface are provided with ture color touch screen containing 800x600 pixels 1 SWITCH 4 COM 2 POWER 1 12 10 6 4 2 11 9 7 5 3 3 LAN 8 8 Fault LED 9 Norm...

Page 7: ...al state There are five different led color combinations which stand for different situations Red led Description Long lighting Go out Go out Go out Long lighting Long lighting Flashes slowly Flashed...

Page 8: ...onnect the power line to charge RJ45 port Connect Shine Pano to the local network or Ethernet As the Figure shows port 2 and port4 are used for RS485 Others for active and reactive power adjustment Au...

Page 9: ...mn M3 5 20 Screw Spike Shine Pano Instruction Disc Bracket Name 1pc 1pc 1pc 1pc 2pcs 2pcs 1pc 1pc The label is sticked on the back side of the Pano indicating the type of product the voltage and curre...

Page 10: ...or other devices like environment monitor and smart meter Pano can correlate with anti flux device to guarantee there s no power sending from PV system to grid Pano has a touch screen which can match...

Page 11: ...of inverters monitored by Pano is more than 1 piece the connection mode between inverters is RS485 As an intermediate device Shine Pano collects the data of PV system and sends it to an upper compute...

Page 12: ...rters The total volume of normal inverters Capacity per day Total capacity Emission of Co2 2 Data of every inverter Operation status ID of inverters Current power Capacity per day Total capacity Total...

Page 13: ...m by Rs485 3 Communication distance in open space is 300m by Zigbee Module 4 The length of cable between router and switchboard should be within 100m 3 2 Installation Methods of Shine Pano 3 2 1 Wall...

Page 14: ...onnect the portal RS485 of Pano with portal RS485 of inverter details refer to chapter 3 3 1 hereinafter or put ZigBee module into portal RS232 of our inverter 5 Cable connection put web cable into LA...

Page 15: ...e SD card cannot be identified 7 Connect the Power supply line 8 Switch on Shine Pano Installation steps 1 Take out the rod from the back of Pano supporting the Pano and then put it on a level 3 2 2 H...

Page 16: ...to the Shine Pano 3 The connection with smart meters and environment monitors is similar with the way with inverters To monitor the environment monitors you can just connect the environment monitor t...

Page 17: ...et the ZigBee ID and Channel Details please refer to the ZigBee Module User Manual which attached to the product when purchased 3 3 2 ZigBee Wireless Conection 3 4 Connection with Network Device We us...

Page 18: ...etting interface is below 15 1 When communicating with RS 485 please set the Address Range in System Set all the inverter address monitored should be within the address range After setting the inverte...

Page 19: ...ated setting Please reset the wireless module after all the setting For more details please refer to ZigBee Module User Manual 4 2 Shine Pano Setting as an Intermediate Device 1 When communicating wit...

Page 20: ...onment monitor setting Fill in the address of environment monitor in and choose ON in the drop down menu 2 Smart meter setting Fill in the address of smart meter in Addren and choose ON in the drop do...

Page 21: ...hine Pano by touching icons or words displayed in the screen and get away from mouse and keyboard 18 5 2 ShinePano Main Interface Open the main interface of Shine Pano on left side of the interface it...

Page 22: ...the Record interface 19 2 Click or touch the word E_Histogram shown in above figure then it will prompt out the drop down menu This menu contains submenu shown in following chart No Description 1 2 3...

Page 23: ...is drop down menu can select the option You can also select the date by clicking box that shows the word 2012 10 23 As shown in following figure select Power Wave in the first box inverter in second b...

Page 24: ...be daily viewed Power and energy curve can be daily monthly and yearly viewed Error information of inverter can only be monthly viewed 5 4 Setting Interface 5 4 1 System Set Interface System setting i...

Page 25: ...efault 2 second by default Address range of inverter Time of inverter location Internet setting options Description Only English now Users don t need to set it Internet Set Remark Local_IP Local_MAC S...

Page 26: ...escription 1 2 3 4 5 6 PV_OnOff PF_CMD Active_P_Rate Reactive_P_Rate Power_factor PFModel Parameter Name Startup Shut down inverter PF commends Active power Reactive power Power factor Enable reactive...

Page 27: ...gs Inda_Reactive Enable inductive reactive power control function Capa_Reactive Enable capable reactive power control function 5 4 3 Extra Set Interface Extra setting interface is shown as following f...

Page 28: ...7 using finger or the stylus to select the communication address of ammeter 37 is default value Select ON or OFF to open or close the communication address of ammeter 4 Power adjust Select ON or OFF t...

Page 29: ...uction to Inverter List Click any inverter shown in inverter list will turn to interface This interface will display following information Running status ID software version communication address and...

Page 30: ...Web Server 1 Connect Shine Pano to local network via network cable 2 Start the web browser enter 192 169 1 230 in the address bar and press the ENTER key 27 3 Click on Record this page is about inver...

Page 31: ...the Parameter 5 Setting parameter A Set the address of the Shine Pano The address setting includes IP address subnet mask default gateway If the first 3 figures of IP address and default gateway are...

Page 32: ...with the network 5 Set the DNS same as the network that you access 6 After configuration click on save at the bottom After setting the IP address successfully restart the Shine Pano then you can get a...

Page 33: ...e domain name The default domain name is server growatt com if user doesn t want to connect the Shine Pano to the default server please change the domain name Set the domain name of the server Shine P...

Page 34: ...11 25 Set ZigBee parameter the range of ZigBee_ID is 1000 9999 the range of I or OFF Set smart meter the address is 37 Open or shut down this function by selecting ON J factory setting select Enable_...

Page 35: ...Access via the Shine Server 1 Start web browser and enter http server growatt com If you are the first time to login please register in advance 2 After registration and fill in the login information...

Page 36: ...viewed via the Shine Station 6 3 1 Installing the Shine Station The installation procedure is brief Just double click the installer and carry out the operation according to the prompt 6 3 2 Logging I...

Page 37: ...e native IP address of the server or computer installed with Shine Station is 192 168 1 74 then enter 192 168 1 74 5678 or 127 0 0 1 5678 in the web browser The operation of the Shine Station could be...

Page 38: ...Click on Start Server enable the monitoring service When the Shine Pano is connected to the Shine station successfully the setting status will display as below 35...

Page 39: ...6 3 4 Checking Up the Data When Shine Pano connects to the Shine Station well the plant status could be viewed by the Shine Station 36...

Page 40: ...this function is required user should activate it The COM ports of the Shine Pano are shown as below Pin 1 3 5 7 9 11 are used to connect the ripple control receiver There are 4 power levels 100 60 30...

Page 41: ...the relay corresponding to pin 3 actions the inverter outputs 100 of nominal power When the relay corresponding to pin 5 actions the inverter outputs 60 of nominal power When the relay corresponding...

Page 42: ...7 5 3 0 99 PF 0 98 PF 0 97 PF 0 95 PF Status When the relay corresponding to pin 9 actions the power factor of the output power is 0 99 When the relay corresponding to pin 9 actions the power factor o...

Page 43: ...r station there are more than one Pano You can choose one Pano as the host connecting to the ripple control receiver The host Pano could send commands to other Panos slave Pano by the local network No...

Page 44: ...41...

Page 45: ...8 Maintenance 8 1 Shine Pano firmware upgrade 42 1 Get upgrade package from Growatt 2 Copy the RAR archive file to the root directory of USB flash disk...

Page 46: ...43 3 Select the RAR archive right click and select Extract here Note You need to have some compressing application like winzip winRAR zip7 or any...

Page 47: ...will restart automatically after successful upgrade Note If the Pano beeps 3 times after restarting this is normal 7 You can check up the firmware version from the touch screen 8 2 Factory Default Not...

Page 48: ...on addresses don t repeat and are in the detecting range of the Shine Pano Please confirm the ID channel of ZigBee Module coincide with that of the Shine Pano If the communication is not OK yet please...

Page 49: ...ation Data storage period System data Maximum 30 inverters 5min ZigBee maximum 15 inverters More than 5 years storage capacity via 2G SD card Inverter list real time power daily energy yield historica...

Page 50: ...47 Interface Language Display screen LED indicator English 800 600TFT true color touch screen System operation state indicator Power supply Input Output 100 240V 50 60Hz 5Vdc 2A...

Page 51: ...our products please contact the Growatt serviceline GROWATT NEW ENERGY No 28 Guanghui Road Longteng Community Shiyan Baoan District Shenzhen P R China Growatt Serviceline Tel 86 755 27471942 E mail se...

Reviews: