Trouble Shooting:

Symptom

Possible Cause

Solution

Low AC output voltage: 190-
210VAC

Using average reading 
Voltmeter

Use true RMS meter and cable

No AC output voltage. Over 
Temp LED On. 

Insufficient ventilation around 

inverter
Ensure true power rating of 
appliance (including power 
factor) is less than inverter 
output rating

Improve ventilation

Check ratings and reduce with 
different appliance

Inverter shuts down when trying 
to start a load

Possible surge from motor 
starting causing shut down

Check that battery voltage is 

within specification. If voltage 

drops excessively when 
starting, batteries size may 
have to be increased. Or load is 
too large for inverter.

Load LED flashes

Overload

Reduce load. Remove load.

No AC output voltage. Bar 
Graph in lower RED zone.

Low input voltage

Check battery status.  
Re-charge if required.

No AC output voltage. Bar 
Graph in upper RED zone.

Excessive input voltage

Check input voltage. 
Reduce if too high.

TV channel interference on 
some channels

Connection of chassis ground 
lug at rear of inverter needs 
attention.

High power loads being used 
during TV viewing.

Ensure TV antenna providing a 
good signal.

DC power cables too long 
causing excessive radiated 
interference.

Check chassis ground lug is a 
solid connection.

Do not use high power loads.

Check antenna wiring and 
connection. Move TV away 
from power inverter.

Shorten cables if necessary 
and twist them together with 
approx. 2 to 3 twists per foot.

Warranty Conditions:

 The product is warranted to be free from defects in materials and workmanship under normal use and 

service for a period of 24 months from the date of sale. This warranty covers defective parts and workmanship provided that 
the product is shipped prepaid to the seller within 24 months of purchase of goods. This warranty is limited to the repair or 
replacement (at the manufacturers’ discretion) of parts and shipping prepaid to the original despatch destination. We regret that 
no liability can be accepted for consequential or special damages of any kind howsoever arising in connection with products 
supplied by the seller. This warranty is in lieu of all other warranties expressed or implied. No representative is authorised to 
assume for the seller any other liability in connection with the seller’s products.

INV12-24-ALL-R1

Unit 2, 1 St James Place, Seven Hills ,NSW,  2147, Australia

Features include:

• Low battery alarm • Low battery shut down • Input voltage (12V Models 10-16VDC) (24V Models 

20-30VDC) • Input low voltage protection • Input high voltage protection • Input short circuit protection 

• Output voltage 220~240VAC @ 50Hz • Output short circuit protection • Overload protection • Over-

temperature protection via internal temperature controlled fan(s) • High efficiency design 85-90% 

efficient • Bar graph displays for battery voltage & load levels (%) (INV1000, 1500, 2500 models) • 

LED displays, indicate power ON & shutdown modes (INV150, 350, 600 models)  

• Aluminium construction heatsink

Safety Instructions

Explosive Gas Precautions:

This equipment contains components that can produce arcs or sparks. To prevent fire or explosion 

do not install in compartments containing batteries or flammable materials, or in locations 

that require ignition-protected equipment. This includes any space containing petrol-powered 
machinery, fuel tanks, joints or other connections between components of the fuel system.

Precautions When Working With Batteries:

• If battery acid contacts skin or clothing, wash immediately with soap and water. If acid gets into 

eyes, immediately flood eyes with running cold water for at least 20 minutes and get medical 

attention immediately. NEVER smoke, allow a spark or flame in the vicinity of batteries or engine. 

Do not drop a metal tool on the battery as the resulting spark or short-circuit of the battery may 
cause an explosion.

• Remove personal metal items such as rings, bracelets, necklaces, and watches when working 

with a lead-acid battery. A lead-acid battery produces a short circuit current, high enough to weld a 
ring or similar metal, causing a severe burn.

Operating Limits:

The inverter will operate most AC appliances within its power rating. 
When operating microwaves, please note that the power commonly advertised for microwave 
ovens is the cooking power (the power delivered to the food) not the power actually used by 

the microwave oven. Microwave ovens generally will consume 40% to 100% more than the 

advertised cooking power. Check the rating sticker at the rear or under the oven to determine its 
actual power draw.

In some cases the power inverter may not be able to start some electric motors even though the 
rated current draw is within the limits of the inverter. If a motor will not start, check the voltage 
reading of the battery voltage indicator. If the voltage indicator reads below 11.0 volts (19V on 
24V models, this could be the reason for not starting. Check that the wire connections are good 
and that the battery is fully charged. If these are ok and you get the same, then this is indicative 
that the inverter is too small for the application.

Page 1of 4

Models:

INV600-12, INV600-24

INV1000-12, INV1500-24,

INV1500-12, INV2500-24, 

INV2500-12

Modified Sine Wave

 DC to 240VAC Power Inverters

12VD

Operating Instructions

Please read these instructions before use

Reviews: