background image

 

 
 
 
 

Weather Resistant VoIP Telephones 

 

WRR/WRT-VoIP Series 

 

Installation & Operation 

 

 

 
 

WRT-10-VoIP WRR-41-VoIP 

P007332 Rev. D 150916 9/16/2015 1:32 PM

Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com  

 

Summary of Contents for P6300

Page 1: ...er Resistant VoIP Telephones WRR WRT VoIP Series Installation Operation WRT 10 VoIP WRR 41 VoIP P007332 Rev D 150916 9 16 2015 1 32 PM Ph 403 258 3100 email info guardiantelecom com www guardianteleco...

Page 2: ...any use of this manual or such products software firmware and or hardware Guardian Telecom Inc reserves the right to make changes without notice to this manual and to any such product software firmwa...

Page 3: ...2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Install in accordance with the manufacturer s instructions 6 Do not install near any heat sources such as radiators heat regis...

Page 4: ...Data Rate 14 13 4 1 Verify Network Activity 14 13 5 RESET Switch 15 14 Announcing the IP Address 15 15 Restore the Factory Default Settings 15 16 Adjust the Volume 15 17 Product Specifications 16 18...

Page 5: ...gdown telephone with 4 curly cord P6305 WRR 41 VoIP Weatherproof ringdown telephone with armored handset cord 3 Options Stainless Steel Mounting Plate MP Standard on WRR 41 VoIP WRT 40 VoIP 20 Heavy D...

Page 6: ...program settings through a web browser to configure telephones on their network WRR 11 VoIP WRT 10 VoIP and WRT 30 VoIP are standard models with a curly cord WRR 41 VoIP and WRT 40 VoIP are vandal re...

Page 7: ...Compatible Receiver Volume Adjustment Compatible with inductively coupled hearing aid devices Adaptive full duplex operation Compatible with most SIP based IP PBX servers that comply with SIP RFC 326...

Page 8: ...Guardian Telecom Inc Installation and Operation WRR WRT VoIP Series Telephones Figure 2 WRT VoIP Features WRR VoIP Similar Figure 3 Overall Dimensions Page 8...

Page 9: ...Guardian Telecom Inc Installation and Operation WRR WRT VoIP Series Telephones J1 STANDARD 8 PIN RJ45 10 100Base T And power input via Power over Ethernet Figure 4 Wiring Page 9...

Page 10: ...on the PCBA Tip Use or M8 screws to secure the unit to the wall If using an alternate power supply connect the supply to the terminal block J9 Before doing so determine if power is supplied over the E...

Page 11: ...sing TFTP Client Facilitates hosting for the Autoprovisioning configuration file RTP Facilitates autoprovisioning configuration values on boot Audio Encodings PCMU G 711 mu law PCMA G 711 A law Packet...

Page 12: ...oltages See Figure 6 Auxiliary Relay Wiring Diagram Warning The relay circuitry contains a non replaceable 250VAC 1A fuse If the fuse blows the board must be returned to Guardian or an approved servic...

Page 13: ...ns and functions Figure 7 Connector Locations Connector Function J1 PoE Network Connection RJ 45 J2 Hands free Microphone Interface LED Interface J3 Not used J4 JTAG Interface J5 Handset Reed Switch I...

Page 14: ...re green Link light above the Ethernet port indicates that the network connection has been established see Figure 8 The Link light changes color to confirm the auto negotiated baud rate This light is...

Page 15: ...ned address or default to 10 10 10 10 if a DHCP server is not present Note Pressing and holding the RESET switch for longer than five seconds will restore the telephone to the factory default settings...

Page 16: ...000 000 OPERATIONS BODY CONSTRUCTION GE VALOX 357 ENGINEERING POLYMER FACEPLATE STEEL CORROSION PROTECTED POWDER COATED DIMENSIONS H X W X D 12 x 9 6 x 3 9 INCHES 305 x 245 x 99 mm NET WEIGHT INCLUDI...

Page 17: ...of the set Handset Replacement Refer to the instruction sheet included with the replacement handset Disconnect the handset wiring from the PCBA If the phone is equipped with an armored cord handset r...

Page 18: ...phone P005778 Faceplate WRR VoIP Ringdown P005784 Access Plate P005837 Reed Switch P007228 Handset 4 Curly Cord C W VC Tx Rx Cn P007230 Handset 22 Armored Cord VC Tx Rx Cn P007319 Ringer Floyd Bell Vo...

Page 19: ...ray the cleaner on a soft cloth then wipe the surface Pre treated cloths like those used for eyeglasses or cameras may be used to clean the Telephone Premoistened towelettes may also be used however a...

Page 20: ...r the purposes of installing the product making adjustments and replacing components following the instructions in the product manual High voltages may be present in this product when wiring is connec...

Page 21: ...ns and the unit fails to operate the user must contact Guardian Telecom to obtain authorization to return the product This can be done by done by completing a RMA form online at www guardiantelecom co...

Page 22: ...Guardian Telecom Inc Installation and Operation WRR WRT VoIP Series Telephones Page 22 Notes Model No Part No Serial No Date of Purchase...

Page 23: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 24: ...ian Telecom Inc Toll free 1 800 363 8010 Phone 403 258 3100 Fax 403 253 4967 www guardiantelecom com E mail sales guardiantelecom com Click to open message box CONNECTED PROTECTED Guardian Telecom Inc...

Reviews: