Product Name: Drop Through Anchor

Instruction Manual

Part #: 00516; 00517; 00518

Do not throw away these instructions!
Read and understand these instructions before using equipment!

Introduction

1

Applicable Safety Standards

1

Worker Classifications

1

Safety Information

6

Product Specific Applications

1-2

Limitations

2-3

Components and Specifications

3-4

Maintenance, Cleaning, and Storage

5

Inspection

5

Installation and Use

4

Inspection Log

5

Labels

7

Summary of Contents for 00516

Page 1: ...nderstand these instructions before using equipment Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Safety Information 6 Product Specific Applications 1 2 Limitations 2 3 Components and Specifications 3 4 Maintenance Cleaning and Storage 5 Inspection 5 Installation and Use 4 Inspection Log 5 Labels 7 ...

Page 2: ...erience or sufficient professional standing who is considered proficient in planning and reviewing the conformity of fall protection and rescue systems Competent Person A highly trained and experienced person who is ASSIGNED BY THE EMPLOYER to be responsible for all elements of a fall safety program including but not limited to its regulation management and application A person who is proficient i...

Page 3: ... to arrest a fall before the user strikes the ground or an obstruction When calculating fall clearance account for a MINIMUM 3 safety factor deceleration distance user height length of lanyard SRL harness stretch and all other applicable factors Diagram shown is an example fall clearance calculation ONLY Swing Falls Prior to installation or use make considerations for eliminating or minimizing all...

Page 4: ...oof Edge Either Direction X Working Angle From Perpendicular Ø 6 10 15 20 25 30 35 40 45 50 55 60 8 9 9 11 7 13 3 14 6 16 17 2 18 3 19 4 19 10 21 4 22 3 53 45 38 33 30 28 26 24 23 21 21 21 For example if the anchorage connector is 6 from the leading edge Y the working distance X is 8 in each direction from the perpendicular which translates to a 53 working angle Connection Point Cable Anchor Plate...

Page 5: ... installed Cable Anchor Plate must lie flush with substrate 5 Make considerations for eliminating or minimizing swing fall hazards Minimum substrate requirements Concrete 4 thick and 3 000 PSI Never install into wet or uncured concrete DO NOT install onto wood or metal substrates Installation 1 If necessary drill 1 75 diameter hole at selected installation location 2 Pass Drop Through Anchor Conne...

Page 6: ...fall arrest Ensure that applicable work area is free of all damage including but not limited to debris rot rust decay cracking and hazardous materials Ensure that selected work area will support the application specific minimum loads set forth in this instruction manual Work area MUST be stable At least every 6 months a Competent Person other than the user must inspect Drop Through Anchor Competen...

Page 7: ...LE SRLs Class A SRLs must arrest falls within 24 Class B SRLs must arrest falls within 54 Harnesses and connectors selected must be compliant with manufacturer s instructions and must be of compatible size and configuration Snap hooks carabiners and other connectors must be selected and applied in a compatible fashion All risk of disengagement must be eliminated All snap hooks and carabiners must ...

Page 8: ...Guardian Fall Protection 6305 S 231st St Kent WA 98032 phone 800 466 6385 fax 800 670 7892 www guardianfall com 7 85155 Rev E Labels ...