background image

Model Numbers: 05649

05650

60 kW

 GENERAC 2.4L ENGINE

•  All input connections in one single area
•  High coolant temperature shutdown
•  Low oil pressure shutdown
•  Low coolant level automatic shutdown
•  Overspeed automatic shutdown
•  Crank timer
•  Exercise timer
•  Oil drain extension
•  Cool flow radiator
•  Closed coolant recovery system
•  UV/Ozone resistant hoses
•  Watertight state of the art electrical connectors

•  Mainline circuit breaker
•  Radiator drain extension
•  Battery charge alternator
•  2 Amp static battery charger
•  Battery and battery cables
•  Battery rack
•  Fan and belt guards
•  Isochronous governor
•  Flex fuel line
•  Hour meter

Liquid Cooled Gas Engine Generator Sets

Standby Power Rating

60 kW 60 Hz

Turbocharged/Aftercooled

Gaseous Fueled

•  Innovative design and fully prototype tested
•  UL2200 Listed
•  Solid state frequency compensated 
 

voltage regulator

•  Dynamic and static battery charger
•  Sound attenuated acoustically designed enclosure
•  Quiet test for low noise level exercise
•  Acoustically designed engine cooling system
•  High flow low noise factory engineered exhaust system

•  State  of  the  art  digital  control  system  with  R100  digital 

control panel

•  Watertight electrical connectors
•  Rodent proof construction
•  High  efficiency,  low  distortion  Generac  designed 

alternator

•  Vibration isolated from mounting base
•  Matching  Generac  transfer  switches  engineered  and 

tested to work as a system

•  All components easily accessible for maintenance
•  Electrostatically applied powder paint

FEATURES

STANDARD EQUIPMENT

Summary of Contents for 05649

Page 1: ...tor Sets Standby Power Rating 60 kW 60 Hz Turbocharged Aftercooled Gaseous Fueled Innovative design and fully prototype tested UL2200 Listed Solid state frequency compensated voltage regulator Dynamic and static battery charger Sound attenuated acoustically designed enclosure Quiet test for low noise level exercise Acoustically designed engine cooling system High flow low noise factory engineered ...

Page 2: ... on utility failure for engine start Low battery Engine warm up before transfer Low oil pressure Delay to retransfer to utility High coolant temp low coolant temp Engine cooldown timer Overspeed Exerciser not set Overcrank Hour meter INTERNAL FUNCTIONS 3 position switch auto off and manual 2 wire start for any transfer switch Communicates with the Generac RTS transfer switch Built in 7 day exercis...

Page 3: ... power 60 Hz cfm 180 SOUND EMISSIONS IN DBA Exercising at 7 meters 65 Normal operation at 7 meters 72 EXHAUST Exhaust flow at rated output 60 Hz cfm 494 Exhaust temp at muffler outlet F 1 050 ENGINE PARAMETERS Rated synchronous RPM 60 Hz 3600 HP at rated KW 60 Hz 94 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration 3 for every 10 C above C 25 1 65 for every 10 F above F 77 Altitude Dera...

Page 4: ... INSTALLATION LAYOUT Installation Drawing Ref No 0F9577 Generac Power Systems Inc P O Box 8 Waukesha WI 53187 generac com 2008 Generac Power Systems Inc All rights reserved All specifications are subject to change without notice Bulletin 0178490SBY Printed in U S A 06 08 rev 10 08 WEIGHT 1650 lbs ...

Reviews: