The
RackConsole 17HR
TFT drawer combines a
high-quality display with a compact keyboard
including a touchpad.
Lieferumfang
TFT drawer
1 pair of telescopic rails with preassembled
fixing brackets
Energy chain with cables
Fasteners
Montage
Position the cage nuts
Bolt the preassembled telescopic rails
together and adjust them in centre to the
height unit (figure 1).
Loosen the screws at the back angle
(figure 2).
Install the rails into the rack.
Extend the middle part of the telescopic
rails and slide the drawer on the rails
(figure 3).
Install the energy chain (figures 4 and 5).
Connect the cables.
Use the handle to pull the drawer out of the
rack.
Lift the display.
The display turns on while it is lifted.
If necessary, press the Power button of the
device (figure 6).
Set the resolution to
1920 × 1200 @ 60 Hz
.
After the operation close the display, if
necessary unlock the telescopic rails, and
slide the drawer back.
Safety Advice
The device must only be maintained by
authorized personnel.
Always unplug the power plug before
opening the device.
Only clean the device when the power plug
is unplugged. Use a dry or damp cloth to
clean the device. Do not use detergents.
The TFT drawer may only be installed into
proper racks located in a clean and dry
environment.
Before using the device check if the plugs
and the cables are connected accordingly.