Ratio Feeder

®

Series J+ Advanced Pumper Controller

GETTING TECHNICAL ASSISTANCE

The H.E. Anderson Company

 is dedicated to assisting our customers with installation and use of our 

products. Our technical staff are available each weekday from 8:30am to 4:30pm central time. You may 
call us toll free at 

1-800-331-9620

 from anywhere in the U.S.A.. and Canada. If no one is available, we 

will promptly return your call.

Before you call,

 we suggest that you review this manual. You may find the answer to your question here.

But even if you do not, reviewing the manual will help us to help you.

There is some information

 you should have available when you call. You should know the software 

version and serial number of your control unit. Also, you should note the number of pumpers of each type,
and their model numbers. We may not need all this information, but having it available at the start can 
some times save a lot of time and trouble for you. You may record the information on the information page
below for convenient reference.

If you need an additional owners manual for any H.E. Anderson Company product, please visit our 
website at 

http://heanderson.com/manuals.php

UNPACKING

Please open and inspect 
your package upon receipt. 
Your package was packed 
with great care and all the 
necessary packing materials 
to arrive to you undamaged. 
If you do find an item that is 
broken or damaged, you 
must contact the delivering 
carrier to report the claim.

Figure 1

J Plus Controller

Summary of Contents for Ratio Feeder J+ Advanced Series

Page 1: ...e when you call You should know the software version and serial number of your control unit Also you should note the number of pumpers of each type and their model numbers We may not need all this inf...

Page 2: ...MPER 3________ PUMPER 4________ PUMPER 5________ PUMPER 6________ PUMPER 7________ PUMPER 8________ GPS Gallons Per Stroke GPS 1________ GPS 2________ GPS 3________ GPS 4________ GPS 5________ GPS 6__...

Page 3: ...modbus manual 2 Water meter connector 3 Output connector 1 through 8 4 Ground connectors 5 Output Type Selector Jumper 2 9 CAN DAMAGE EQUIPMENT IF SET INCORRECTLY 6 Flowmeter Voltage Jumper 1 DO NOT A...

Page 4: ...ief bushing on the bottom of the box then connect the wires up to the proper output terminal number For Anderson Pilot Valve Manifolds match the 1 2 and 3 on the output cable to the corresponding numb...

Page 5: ...itional Anderson manifold pilot valve or a solenoid pump Upper position for Anderson Pilot Valve Manifolds Lower position for Solenoid Pumps Ensure the jumper positions are set properly Check each out...

Page 6: ...e If the above message is not displayed then unplug the box immediately and consult the factory for further instructions Setting Up the Controller The controller must be configured in order to work pr...

Page 7: ...the screen will return to the base display All numeric entries are right justified as they are entered Decimal places are fixed and when entering values with decimal positions trailing zeros must be e...

Page 8: ...oid Pump J Plus Advanced Start Up Guide Page 2 Turning Global Chemical Feed On or Off Enter switches to alternate state FEED IS ON to FEED IS OFF or FEED IS OFF to FEED IS ON Cancel Enter Exit Loop un...

Page 9: ...nge or clear the security code press Enter and follow the prompts Entering 0000 for the code will clear the code and turn off security The K Factor value is critical to accurate operation of the syste...

Page 10: ...the fastest lowest VPS value stroking manifold or Solenoid pump reaches its maximum stroking rate Each output has its own maximum flow determined by its VPS setting The lowest of these values is disp...

Page 11: ...complete information If you need to return any parts for service or replacement our shipping address is H E Anderson Company 2100 Anderson Drive Muskogee Oklahoma 74403 USA Please enclose a note deta...

Reviews: