background image

 

 

 
             
 

 

CDMA Gateway Instruction   

 

(H3G-650) 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

H3 System Co., Ltd 

 
 

   
 
 
 
 

                                                               

Summary of Contents for H3G-650

Page 1: ...CDMA Gateway Instruction H3G 650 H3 System Co Ltd ...

Page 2: ... Revision Notes No Date Version Content Author ...

Page 3: ...figuration software For the details please see the section below Gateway configuration C Pairing and testing i Pair with devices Please see Pairing section below ii Take readings and confirm if the readings are successfully delivered to a server Please see Measurement and data transmission section D Final inspection i Confirm the mode selection switch at N If not set the switch at N ii Prepare dry...

Page 4: ...t vi Devices List List of paired devices Types and BT addresses vii Delete List Delete all pairing info viii Clear Button Clear window ix Send Button Send a new configuration to the gateway x CDMA Log CDMAAT command logs 3 Steps A Turn off the gateway B Connect a serial cable provided by H3 System to a gateway and a PC C Run the configuration software D Select the suitable COM port You can check t...

Page 5: ... D weighing scale UC 321PBT and blood pressure monitor UA 767PBT C P2 Used for GMA BA 100 for Lifescan s blood glucose meter OneTouch Ultra OneTouch Mini Easy OneTouch Ultra2 IEM blood pressure monitor Stabil O Graph ForaCare s thermometer FORA IR20b and Beijing Choice s Pulse Oximeter MD300C318 2 Pairing process A General process i Turn off the gateway ii Set the mode selection switch at suitable...

Page 6: ...h at P1 iii Turn on the gateway iv The gateway shows the number of currently paired devices with LEDs for 5 seconds v The Readings LED turns GREEN vi Take a reading with the blood pressure monitor or weighing scale vii At success the Readings LED blinks GREEN 5 times viii At failure the Readings LED blinks RED 5 times ix The gateway goes to the step iv x You can pair another device at P1 mode succ...

Page 7: ...Ds for 5 seconds v The Readings LED turns GREEN vi Wait for about a few minutes vii At success the Readings LED blinks GREEN 5 times viii At failure the Readings LED blinks RED 5 times ix The gateway goes to the step iv x You can pair another device at P2 mode successively xi After completion of pairing you should turn off set the mode selection switch at N and turn on the gateway for normal opera...

Page 8: ...riod until success 2 Clock setup A Clock of the gateway is automatically set with CDMA connection B Clocks of measuring devices can be set during communication with the gateway C But regarding the IEM s blood pressure monitor clock must be set manually 3 LED indications A During Bluetooth communication the Readings LED turns GREEN B At success the Readings LED blinks GREEN 5 times C At failure the...

Page 9: ... be generated at the folder defined at DATA_PATH B Log files will be generated at the folder defined at LOG_PATH C Examples Ex Data XML file name H3_20101004194422_1111111111 xml Creation logic of xml file name Datetime gateway serial no Ex Log file name H3_20101004194422_156 log Creation logic of log file name Datetime 6 XML file xml version 1 0 encoding utf 8 Measure serial 1111000002 dc 1 batte...

Page 10: ...e Thermometer Data id 00123E0019B5 measuretime 20100101001000 otemp 97 88 btemp 83 66 unit F Device Device type Pressure_IEM Data id 61102DM2 measuretime 20110215151641 sys 157 dia 100 pul 091 con_gwtime 20111221132941 con_devtime 20111221132941 Device Device type OXI Data id 0018E41E7B7F measuretime 20100116012117 pid 001 temp 000 pr 075 spo2 90 battery 10 con_gwtime 20111221132941 con_devtime De...

Page 11: ... sys 139 Systolic dia 091 Diastolic pul 094 Pulse rate battery 2 63 Battery Weight Scale result 066 80 Measurement value unit kg Unit kg or lb battery 2 32 Battery Thermometer otemp 98 42 Object Temperature Body temperature btemp 74 84 Back ground temperature Outside temperature unit F Unit F Fhar BP Monitor IEM sys 157 Systolic dia 100 Diastolic pul 091 Pulse rate Oximeter pid 001 PID temp 000 Te...

Page 12: ...ference to radio or television reception which can be determined by tuning the equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the distance between the equipment and the receiver Connect the equipment to outlet on a circuit different from that to which the receiver is connec...