background image

LAST UPDATED: 11/30/2018

MDC-500

- Rotary Unit Installation

Prerequisites

Make sure that the MDC-500 has the additional axis drives installed to support the additional axis. If a second mocon

PCB is required, make sure it is installed before installing the additional axis.

Electrical Safety

Caution:

When you do maintenance or repair on CNC machines and their components, you must always follow

basic safety precautions. This decreases the risk of injury and mechanical damage.

• Set the main circuit breaker to the

[OFF]

position.

Danger:

Before beginning any work inside the control cabinet the High Voltage indicator light on the 320V Power

Supply / Vector Drive must have been off for at least 5 minutes.

Some service procedures can be dangerous or life-threatening. DO NOT attempt a procedure that you do not fully

understand. If you have any doubts about doing a procedure contact your Haas Factory Outlet (HFO) and schedule a

service visit.

MDC-500 Rotary Unit Installation

Page 1 of 8 pages

Summary of Contents for MDC-500

Page 1: ... basic safety precautions This decreases the risk of injury and mechanical damage Set the main circuit breaker to the OFF position Danger Before beginning any work inside the control cabinet the High Voltage indicator light on the 320V Power Supply Vector Drive must have been off for at least 5 minutes Some service procedures can be dangerous or life threatening DO NOT attempt a procedure that you...

Page 2: ...MDC 500 Rotary Unit Installation MDC 500 Rotary Unit Installation Page 2 of 8 pages ...

Page 3: ...height capacity before you command a pallet change Secure the rotary unit to the table with T nuts 3 Follow the routing shown to bring the rotary unit cables and air hose through the grommet holes and up to the cable bracket support box on top of the machine Press the 2 piece grommet plate into place 4 Connect the quick release air hose fitting to the air supply outlet in the cable bracket support...

Page 4: ... Rotary Index from the outside of the enclosure and attach it with the metal locking nut from the inside Push the plastic switch assembly onto the push button from the inside Slide the tab at the top of the switch assembly to secure it in place 9 Attach the yellow lead 1 of the rotary index cable to the top of the switch and the white lead 2 to the bottom Replace the panel and back cover MDC 500 R...

Page 5: ...10 Disconnect the pallet changer amplifier cable from its socket on the first Mocon PCB and connect it to the Z Axis socket on the second Mocon PCB MDC 500 Rotary Unit Installation Page 5 of 8 pages ...

Page 6: ...MDC 500 Rotary Unit Setup and Configuration MDC 500 Rotary Unit Installation Page 6 of 8 pages ...

Page 7: ...6 3 DISABLED to 0 Set Parameter 708 PALLET CHANGER AXIS to 8 Set Parameter 737 1 ROTARY INDEX BUTTON to 1 Enable Setting 30 Fourth Axis Enable Setting 78 Fifth Axis Set Setting 164 ROTARY INCREMENT to 90 2 Press MDI DNC Type M17 and press WRITE ENTER 3 Press CYCLE START to unclamp the pallet Wait until the assembly has risen to its highest point Press EMERGENCY STOP MDC 500 Rotary Unit Installatio...

Page 8: ...sufficiently clear the machine walls 5 Align the pallet as close to the home position as possible Reset the EMERGENCY STOP button 6 Press ZERO RETURN Type in the letter of the axis of the pallet Press SINGLE to align and reclamp the pallet MDC 500 Rotary Unit Installation Page 8 of 8 pages ...