background image

Luzern

1

28 mm x 135 mm
4000 mm x 3000 mm
4560 x 3440 mm
16 m²
2660 mm
895 mm x 1820 mm
640 mm x 870 mm
1960 mm

Luzern

271205

Nordic region spruce wall boards
Dimensions of pedestal
Outer dimensions incl. roof overhang
Area of roof
Height of ridge
1 glazed door width x height
2 glazed windows width x height
Height of side walls

(All measurements approximately)

4000 mm x 3000 mm

Wall thickness 28 mm

Ground plan and

foundation plan

Placing the foundation beams 7 pcs.

1

5

7

6

4

3

2

Summary of Contents for Luzern 727

Page 1: ...spruce wall boards Dimensions of pedestal Outer dimensions incl roof overhang Area of roof Height of ridge 1 glazed door width x height 2 glazed windows width x height Height of side walls All measure...

Page 2: ...tor is recommended or paint please take notice of the recommendations of the varnish or paint manufacturer It is not advisable to paint the wall timbers before assembling them this is best done when t...

Page 3: ...3 1 Side walls C Rear wall B Front wall A Luzern 271205...

Page 4: ...base forthe floor joists and is also good forventilation lengthwise diagram 2 Pre sorting 2 4 Pre sorting you don t need to worry about the number of parts when you open the package Please refer to fo...

Page 5: ...ere in the assembly process To avoid damage we have enclosed wooden blocks marked with an X to be placed on the planks for protection purposes the ends of the timbers protruding at the corners require...

Page 6: ...nt for a log cabin structure your summer house will settle up to 3 4 cm during the course of the different seasons and varying weather conditions To allow for this there has to be some otherwise the h...

Page 7: ...dunderextremeweatherconditions andadjustingthemas required This should be done by adjusting the whole frame using gentle taps of the rubber mallet please use wooden blocksinbetween or by tighteningor...

Page 8: ...ve upwards Attachthefasciaboards C4 flush withtheroof Thenthework canbeginon theroofingshingles Here again any unevenness caused by the planer rough edges etc even in the grooves and tongues are due t...

Page 9: ...ling of the first row of shingles position the next row in alignment with the previous row the next row must also cover the nails of the previous row Continue installation in accordance with Pic B Cut...

Page 10: ...ing enclosed bolts with the nuts facing inwards It is important not to tighten the top nuts too firmly toallowthestructureroomto settle screw thestrips down firmlyusing theremainingbolts Please take c...

Page 11: ...n when removing and replacing the window cross since it is a tightfit Regular visual checks help to avoid damage before it occurs Please remember that fitting adjustments to the differentpartsareanuna...

Page 12: ...List of parts 10 12 Luzern 271205...