2941/2942 Magnetic Lock
Installation Instructions
I-EA00053
Rev 5, Rev Date: 11/15/22
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104
• (800) 325
-
9995
The 2941 & 2942 magnetic locks are mounted to the underside of the header, on the stop side of
the door.
INSTALLATION INSTRUCTIONS
2941/2942 MAGNETIC LOCKS
Electrical Guidelines:
•
Use properly fused U. L. Listed Power Supply
•
Do not install a diode in parallel with any magnetic lock. A diode will cause a delay when releasing the door and
residual magnetism to occur.
•
Any low voltage condition will cause erratic operation of the optional board sensor.
Mechanical Guidelines:
•
Handle the equipment with care, damaging the mating surfaces of the magnet or armature plate may reduce locking
efficiency.
•
The magnet mounts rigidly to the door frame. The armature plate mounts to the door. The kit provided allows the
armature to pivot about its center to compensate for door wear and misalignment.
•
Template use must take place with the door installed in its normally closed position (do not pre-prep door and frame
separately or alignment issues may occur).
•
Before installing, add thread-locker to all screws.
Maintenance Guidelines:
•
Do not touch the lock face with your hands.
•
Clean lock face with scouring pad (do not use sandpaper).
•
Apply a thin film of rust inhibitor on lock face.
•
Repeat application on armature plate.
Electrical Specifications:
Dual Voltage
12 or 24VDC
Power Consumption
505mA@12VDC
260mA@24VDC
DS Door Position Sensor SPDT, 1A@24VDC
LS Lock Status Sensor SPDT, 1A@24VDC
Supplied Mounting Hardware (2941 & 2942)