background image

2941/2942 Magnetic Lock

Installation Instructions

I-EA00053

Rev 5, Rev Date: 11/15/22

Always visit www.hagerco.com for the latest Installation Instructions

HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 

• (800) 325

-

9995

The 2941 & 2942 magnetic locks are mounted to the underside of the header, on the stop side of 

the door.

INSTALLATION INSTRUCTIONS

2941/2942 MAGNETIC LOCKS

Electrical Guidelines:

• 

Use properly fused U. L. Listed Power Supply

• 

Do not install a diode in parallel with any magnetic lock.  A diode will cause a delay when releasing the door and 
residual magnetism to occur.

• 

Any low voltage condition will cause erratic operation of the optional board sensor.

Mechanical Guidelines:

• 

Handle the equipment with care, damaging the mating surfaces of the magnet or armature plate may reduce locking 
efficiency.

• 

The magnet mounts rigidly to the door frame.  The armature plate mounts to the door.  The kit provided allows the 
armature to pivot about its center to compensate for door wear and misalignment.

• 

Template use must take place with the door installed in its normally closed position (do not pre-prep door and frame 
separately or alignment issues may occur).

• 

Before installing, add thread-locker to all screws.

Maintenance Guidelines:

• 

Do not touch the lock face with your hands.

• 

Clean lock face with scouring pad (do not use sandpaper).

• 

Apply a thin film of rust inhibitor on lock face.

• 

Repeat application on armature plate.

Electrical Specifications:

Dual Voltage

12 or 24VDC

Power Consumption

505mA@12VDC

260mA@24VDC

DS Door Position Sensor     SPDT, 1A@24VDC

LS Lock Status Sensor        SPDT, 1A@24VDC

Supplied Mounting Hardware (2941 & 2942)

2942 only