6LE007713B
01
WBMDUR
Rotary dimmer
Hager Electro Pty. Ltd., Unit 17/2-8 South Street, RYDALMERE NSW 2116, AUSTRALIA
The terminal block must be mounted in either
its original shipped position or on the rear of the
module by means of the enclosed cable tie.
(1) Rotary knobs
(2) Retaining lugs for Rotoloc
®
fastening
(3) Connection cable
(4) Terminal block
Function
Correct use
- Switching and dimming of incandescent lamps,
HV halogen lamps and dimmable 230 V LED
lamps; electronic transformers with low voltage
halogen lamps.
- Unsuitable for fans and motors
- Suitable for indoor use only, but no drip and no
spray water.
- Suitable for Hager Rotoloc switch plates only
Product characteristics
-
Phase cut-off dimmers
- Wide dimming range down to the lowest
brightness for many lamps
- Programmable minimum brightness
-
Additional configurable functions
-
Automatic storage of the switch-off brightness
level as switch-on brightness level
- Electronic short circuit, overload and thermal
protection
- Multi-way dimming available only with use of
the WBMSLL slave mechanisms
- Non volatile device settings
Control
Fig. 3: Rotary dimmer operation
Load
state
Action
Result
OFF
Short press
rotary knob
Switch
ON
with saved
switch-on brightness
level.
> 0% Short press
rotary knob
Switch
OFF
and save
brightness as switch-
on brightness level.
> 0% Turn rotary knob
anticlockwise
Dim down the light.
> 0% Turn rotary knob
clockwise
Dim up the light.
Table 1: Rotary dimmer operation
Fig. 4: Optional slave unit operation
Load
status
Action Result
OFF
Short
press of
push-
button
Switch
ON
with saved switch-
on brightness level.
> 0%
Short
press of
push-
button
Switch
OFF
and save bright-
ness as switch-on brightness
level.
> 0%
Long
press of
button
With every long push-
button operation within 12 sec:
Dimming with alternating direc-
tion, otherwise device will dim
up, until max. level is reached.
Table 2: Operation on slave unit / push-button
Adjusting the minimum brightness for the
rotary dimmer
The minimum brightness level can be adjusted to
prevent poor switch-on behaviour or flickering of
the load in the lower dimming range.
Switch off load.
Press and hold rotary knob for approx 10
seconds.
The load will flash once after 3 seconds and
then flash a second time after 10 seconds.
Release the rotary knob.
The device is in fine adjustment mode for the
minimum brightness level and the lamp is
switched on at the minimum brightness level.
Depending on the lamp, the minimum bright-
ness level of the lights installed may be too
low and the lights may appear off, gradually
increase the brightness level by rotating the
knob clockwise.
If no actions are performed within 10 seconds,
the dimmer exits programing operation.
Gradually turn the rotary knob anticlockwise.
This reduces the minimum brightness.
Gradually turn the rotary knob clockwise.
This increases the minimum brightness.
Once desired min lighting level is reached, wait
10 seconds for device to store the setting.
The load will be switched off, the dimmer re
-
turns to normal operation.
Configurable additional functions
The additional functions can be configured by
pressing the rotary dimmer for the required number
of times.
Kick-start
A short voltage burst when lamp is initially turned
on to support lamp start-up.
Reduced maximum brightness
A non-adjustble voltage reduction for suppressing
flickering at maximum brightness.
Recovering the previous load state when power
is restored after a power cut
The status of the load prior to power loss will be
restored at power-on.
Configuration additional functions
Switch off load.
Press and hold rotary knob for approx 10
seconds.
The load will flash once after 3 seconds and
then flash a second time after 10 seconds.
Release the rotary knob.
The device is in fine adjustment mode for the
minimum brightness level and the lamp is
switched on at the minimum brightness level.
Safety instructions
Electrical equipment must only be installed and
assembled by a qualified electrician in accord
-
ance with the relevant installation standards,
guidelines, regulations, directives, safety and ac-
cident prevention regulations of the country.
Failure to comply with these instructions may re-
sult in damage to the device, fire or other hazards.
Hazard due to electric shock. The device is not
suitable for safe disconnection of the mains sup-
ply. Even when the device is switched off, the
load is not isolated from the mains supply.
Do not connect non-dimmable lamps, their trans-
formers or operating devices. Observe manufac-
turer's data.
These instructions are an integral component of
the product and must be retained by the end user.
Design and layout of the device
(2)
(1)
(3)
Fig. 1: Front view
(2)
(3)
(4)
Fig. 2: Rear view