Installation Manual of Room Air Conditioner

Tool necessary

1. Screw driver

2. Hacksaw

3. 70mm dia.hole core drill

4. Spanner(dia. 17,27mm)

5. Spanner(14,17,19, 27mm)

6. Pipe cutter

7. Flaring tool

8. Knife

9. Nipper

10. Gas leakage detector

or soap water

11. Measuring tape

12. Reamer

13. Refrigerant oil

Standard accessories

Following parts shall be field

supplied

Mark

Part name

Adhensive tape

Pipe clip

Connecting hose

Insulation material

Putty

Drain hose

A

B

C

D

E

F

No.

Shape and description

QTY

Remote controller

Cement nail

Connecting pipe

Drain hose

Wire clip

Rubber pad

Non-adhensive tape

Fixing of the unit

1. Position of the wall hole

Wall hole should be decided according to installation
place and piping direction.(refer to installation drawings).

2. Making a wall hole

Drill a hole of 70X70mm dia. with a little slope towards
outside.

Indoor side

Outdoor side

Thickness

of wall

Wall hole

70mm

(Cross section of wall hole)

Insulation pipe

Dry battery #7

Wall hole cover

Piping hole cover

signal  hose

Summary of Contents for HPU-18C03/E1

Page 1: ...onnecting hose Insulation material Putty Drain hose A B C D E F No Shape and description QTY Remote controller Cement nail Connecting pipe Drain hose Wire clip Rubber pad Non adhensive tape Fixing of the unit 1 Position of the wall hole Wall hole should be decided according to installation place and piping direction refer to installation drawings 2 Making a wall hole Drill a hole of 70X70mm dia wi...

Page 2: ...unit with union of connection pipe Arrange the piping as per the wall hole and bind drain hose connecting electric cable and piping together with polyethylene tape Insert the bound piping connecting electric cable and drain hoes through wall hole to connect with outdoor unit 2 Arrangement drain hose Drain hose shall be placed in under place There should be a slope when arrange drain hose Avoid up ...

Page 3: ...mage the threads and cause a leakage of gas Liquid Side 9 52mm 3 8 Gas Side 15 88mm 5 8 60N m 42N m 15 88mm 5 8 9 52mm 3 8 Liquid side Gas side 2 way valve 3 way valve Note When extending piping air inside piping shall be removed by using external refrigerant gas charge according to the following list Brand new outdoor unit is charged 50g or 80g 22k 24k more refrigerant than regulated weight Only ...

Page 4: ... cable gently to make sure it is tight Replace cover after wiring Wiring of outdoor unit Insert the cable from inside the wall hole where piping already exist Pull it out from front Loose terminal screw and insert cable end fully into terminal block then tighten it Pull the cable gently to make sure it is tight Replace cover after wiring When connecting indoor and outdoor wire check the number on ...

Page 5: ...and test run Please operate unit according to this Manual Items to be checked during test run Please made a in Are there any gas leakage How is insulation at piping connection carried out Are electric wires of indoor and outdoor unit firmly inserted into terminal block Is electric wiring of indoor and outdoor securely fixed Is drainage securely carried out Is earth line grounding securely connecte...

Reviews: