background image

TT Basic-Engelska 

 

 

USER GUIDE 

ORIGINAL INSTRUCTIONS 

 
 
 

 

BASIC 

 
 

                                  

 

 
 

Hallins Sales AB  
Box 24 
SE-599 21  ÖDESHÖG 
 
Tel.: 

 

   

+46 (0)144-15300

                                

 

Fax: 

 

   

+46 (0)144-31400

                                    

Email: 

    

support@hallins.com

                          Version: 1.0

 

Web: 

     

www.hallins.com

 

 

or  

 

www.temptainer.se

  

      Date: 02/09/2016

 

Summary of Contents for M6060012-01

Page 1: ...ka USER GUIDE ORIGINAL INSTRUCTIONS BASIC Hallins Sales AB Box 24 SE 599 21 ÖDESHÖG Tel 46 0 144 15300 Fax 46 0 144 31400 Email support hallins com Version 1 0 Web www hallins com or www temptainer se Date 02 09 2016 ...

Page 2: ...ITH COMPRESSOR ACTIVE COOLING TECHNOLOGY 9 TEMPTAINER BASIC WITH COMBINED ACTIVE HEATING AND ACTIVE COOLING 9 TEMPTAINER BASIC IN NEUTRAL DESIGN 10 TRANSPORT 10 7 MAINTENANCE AND TROUBLESHOOTING 11 CLEANING 11 MAINTENANCE 11 TROUBLESHOOTING 12 8 OVERVIEW AND TECHNICAL DATA 13 OVERVIEW general information 13 DIGITAL DISPLAY CONTROL 14 SINGLE 155 TOWER 166 9 SPARE PARTS 177 10 STICKERS 18 12 OPERATI...

Page 3: ...ration inspections and maintenance of this machine are critical for executing your work effectively and safely and for the trolley s useful life This manual must be available to all relevant personnel be kept in a protected place and accompany the product if transferred to another location If you have any questions contact your supplier The relevant part number and serial number may be found on th...

Page 4: ...eviations from the above must ALWAYS and IMMEDIATELY be noted on the consignment note before acknowledging receipt of the shipment to the carrier Also contact Hallins ideally at once but no later than three days after receipt of the shipment Tel 46 144 15 300 ask for Sales Support Email claim hallins com Temptainer Basic are normally delivered upright on a pallet enclosed in protective plastic and...

Page 5: ... warranty also applies in accordance with the following provisions BFS 2009 General provisions for the supply of catering equipment NL 09 General provisions for the supply of machinery and other mechanical electrical and electronic equipment ORGALIME 2012 General provisions for the supply of machinery and other mechanical electrical and electronic equipment ...

Page 6: ...olley that affect operational safety are not permitted It is extremely important that users are familiar with how the trolley works and the correct way to use it The rules of the Swedish Occupational Safety Authority Arbetsskyddsverket must always be observed minimum requirements in accordance with Directive 2009 104 EC IMPORTANT The food trolley may only be used for its intended purpose and by pe...

Page 7: ...G WORK Maintain full supervision of the trolley when it is moving Look out for other mobile machines and objects in the vicinity Be aware of the risk of tipping The trolley may only carry loads for which it is designed and these loads must be stable and securely arranged Do not let the trolley come into contact with other objects Be aware of the risk of trapping when working with trolleys on wheel...

Page 8: ... 2 The temperature indicator on the door of the trolley shows the actual temperature reached in the trolley 3 When the temperature in the trolley has reached the right level vessels containing hot food may be placed in the trolley 4 Only place well heated items in the hot cabinet Bear in mind Use containers with lids for the best temperature retention and avoid opening them and the doors unnecessa...

Page 9: ...ched in the trolley 3 When the temperature in the trolley has come down to the right level vessels containing food may be placed in the trolley 4 Only place well cooled items in the cold cabinet Bear in mind Use containers with lids for the best temperature retention and avoid opening them and the doors unnecessarily The better the areas are filled the better the ability to maintain the correct te...

Page 10: ...neutral design has neither active cooling nor heating but is used primarily to transport food It is however easier to maintain the temperature of the food using the trolley In order to maintain the low temperature of cooled items the trolley may be placed in a cold room before use and fitted with cooling and freezing lamps TRANSPORT The Temptainer Basic is designed to be used to transport food in ...

Page 11: ...g As the Temptainer Basic contains electrical components it is very important that cleaning is carried out with care The Temptainer Basic may be cleaned using standard detergents used in restaurants and catering operations NOTE Corrosive detergents may not be used MAINTENANCE In order for your Temptainer Basic to work in the best possible way it is important to perform regular maintenance in accor...

Page 12: ...o the mains B Check that the unit is in on mode ON OFF button C Check that the flex holder has not been damaged D Check that the connections in the trolley and flex holder are intact E Contact a qualified service engineer Trolley with active cooling does not cool down A Check that the flex holder is connected to the mains B Check that the unit is in on mode ON OFF button C Check that the flex hold...

Page 13: ...ides with guide gaps of 80 mm The trolleys are adapted to gastronorm standards and only gastronorm containers trays etc may be used There are three different models Single and Tower each of which can have the following functions neutral N active heating HS active cooling CC or a combination of these Cooling is based on compressor technology CC The Neutral N trolley has no active heating or cooling...

Page 14: ... set point will be displayed and the C or F LED icon will start blinking 3 To change the Set point value push the UP or DONW buttons within 10s 4 To memorise the new set point value push the SET button again or wait for 10s 4 3 HOW TO LOCK THE KEYBOARD 1 Keep pressed for more than 3 s the UP DOWN buttons 2 The PoF message will be displayed and the keyboard will be locked At this point it will be p...

Page 15: ...a Single N M6060012 01 Guide pair qty 12 Width x depth mm 500x770 Height mm 1380 Weight kg 50 Capacity litres Max 120 Wheel diameter mm 160 mm 2 fixed 2 swivel brake Figure 1 Main parts of Temptainer Basic in Single design 1 Handle bumper 4 Bumper 2 Temperature indicator 5 Wheel with foot brake 3 Handle door lock 6 Power cable not in neutral trolley 2 3 1 4 5 1 4 6 The item on the picture is equip...

Page 16: ...al data Single CC M6064012 01 Guide pair qty 12 Width x depth mm 500x835 Height mm 1380 Weight kg 65 Capacity litres Max 120 Output W 230 240 V 50 60 Hz 1 phase 136 Wheel diameter mm 160 mm 2 fixed 2 swivel brake TOWER The Tower trolley has double compartments stacked The compartment can be combined in any way for cold hot or neutral storage Figure 2 Tower model with active heating and active cool...

Page 17: ...full range of spare parts Returning spare parts Do not return spare parts that have been worn through normal usage or damaged in an accident Return worn damaged or unusable parts if the defect is considered to fall under the warranty obligation If this is the case return the parts immediately as you may otherwise forfeit your right to a replacement When ordering spare parts please quote the trolle...

Page 18: ...18 10 STICKERS Machine sign individual ...

Page 19: ...AINTENANCE DATE SIGNED OBSERVATIONS SERVICE MAINTENANCE DATE SIGNED OBSERVATIONS SERVICE MAINTENANCE DATE SIGNED OBSERVATIONS SERVICE MAINTENANCE DATE SIGNED OBSERVATIONS SERVICE MAINTENANCE DATE SIGNED OBSERVATIONS SERVICE MAINTENANCE DATE SIGNED OBSERVATIONS SERVICE MAINTENANCE DATE SIGNED OBSERVATIONS SERVICE MAINTENANCE DATE SIGNED OBSERVATIONS SERVICE MAINTENANCE DATE SIGNED OBSERVATIONS SERV...

Page 20: ...cialist companies take care of worn out trolleys dismantle them and utilise any materials that can be reused Electrical items must be taken to special collection points for electrical materials Hallins Sales AB can offer a service to take care of worn out Temptainer Basic Contact Hallins Sales AB for further information ...

Page 21: ...nery as well as the Low Voltage Directive 2006 95 EC and the EMC Directive 2004 108 EC Serial No ________________________________________ Product no Single M6060012 01 M6062012 01 M6064012 01 Tower M6071066 01 The relevant parts of the following harmonised standards have been observed in design and manufacture EN 60335 1 Household and similar electrical appliances Safety General requirements EN 60...

Reviews: