background image

Hereford 

Wood/Multifuel Stoves

Operating & Installation Manual

PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

Hereford 7 Flat Multifuel Stove

Rev 1

August 2004 

Part No. AFS1176

Summary of Contents for Hereford

Page 1: ...Hereford Wood Multifuel Stoves Operating Installation Manual PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Hereford 7 Flat Multifuel Stove Rev 1 August 2004 Part No AFS1176...

Page 2: ...ned which is why we are so confident in the reliability of our product Should you have any questions about our Hamlet Stoves that are not covered in this manual please contact the local dealer in your...

Page 3: ...sh Removal 12 Over Firing 12 SERVICING Cleaning 12 Annual Maintenance 13 INSTALLATION Page General Precautions 14 Handling 14 Hearth 14 Combustible Materials 14 Firebox Liner Panels 15 Throat Plate In...

Page 4: ...BURNED IN THIS APPLIANCE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www solidfuel co uk THE USE OF SPARE PA...

Page 5: ...perly installed and operated a house fire may result installation must comply with the Building Regulations and conform to all relevant fire safety standards Arada Ltd produce a variety of appliances...

Page 6: ...cale 4 Flue spigot 5 Hotplate 7 Operating tool 8 Rear liner 9 Side liners Hereford 7 Wood Multifuel Hereford 10 Wood Multifuel 1 1 1 5 1 2 2 1 5 1 Wood and Multifuel Grate 3 Throat plate 6 Ashpan 1 4...

Page 7: ...Centre of Rear Flue Depth from Back to Centre of Flue mm Flue Diameter Weight Packed Kg 1 7 Hereford 7 Flat 8 4 8 2 2 510 486 359 396 121 127 5 48 Hereford 7 Low 1 7 8 4 8 2 2 680 486 359 396 109 127...

Page 8: ...h has an internal sliding plate with slots housed in a cover plate and is located above the fire door Sliding the control knob to the right as far as it will go achieves the fully open position Slidin...

Page 9: ...flat and in contact with the glass Fig 7 Fig 7 Fitting door glass Replace the two retaining clips and nuts Do not over tighten the nuts as damage may occur to the glass Fig 8 Re place the doors carefu...

Page 10: ...himney and the appliance and increase the risk of chimney fire Note If you have sticky tar inside the appliance or chimney your wood is Green or too wet Recommended Reading Wood as Fuel available from...

Page 11: ...use a fire lighter If using a gas poker be sure to remove it immediately the fire is alight When the fire is well alight regulate the burning rate by adjusting the setting on the primary air inlet co...

Page 12: ...order to protect it so de ashing should cease as soon as the first red embers drop into the ash pan Further de ashing will cause heat build up under the grate which will considerably shorten its life...

Page 13: ...shut down period DOOR GLASS The door glass should remain clear during normal daytimeburning Howeverundercertainconditions such as burning at a low rate with damp wood or overnight burning the glass ma...

Page 14: ...H The fire should be installed to stand on a constructional hearth of non combustible materials not less than 125mm 5 thick conforming to Building Regulations Dimensions of the hearth should project a...

Page 15: ...it on top of the side liners The long centre tab on the back edge rests on the rear liners The shorter turn down tabs against the vertical face Note Neither the rear firebox liners nor the side firebo...

Page 16: ...d Multifuel Stoves INSTALLATION Fig 14 They are fitted as follows To fit the interchangeable canopy Fig 10c Remove the front clamps Tilt the canopy as shown in stage 1 Engage the rear clips and pull f...

Page 17: ...fumes from the stove outlet to the outside air To ensure a good updraught it is important that the flue gases are kept warm and that the flue size suits the stove The termination of the outlet at the...

Page 18: ...cument J of the Building Regulations for England and Wales is available from The Stationery Bookshops and can also be viewed at the ODPM website at www safety odpm gov uk bregs brads htm Details on th...

Page 19: ...Hereford Wood Multifuel Stoves 19 INSTALLATION...

Page 20: ...ULATED FLUES TYPICAL METAL INSULATED CHIMNEY SYSTEM TO BE INSTALLED TO THE CHIMNEY MANUFACTURERS INSTRUCTIONS IN COMPLIANCE WITH BUILDING REGULATIONS AND BS7566 PTS 1 4 A is minimum clearance for non...

Page 21: ...ndividual heating systems should be carried out by a qualified heating engineer In many cases your supplier will be able to offer advice and assistance Direct Systems Stainless steel boilers either fa...

Page 22: ...from the expansion tank should be 28mm diameter copper Pipes in unheated spaces must be lagged FINAL CHECK Before handing over the installation to the customer it is strongly recommended that the appl...

Page 23: ...s appliances only c If clay or concrete flue liners used confirm that they are correctly jointed with socket end uppermost and state jointing materials used d If an existing chimney has been refurbish...

Page 24: ...7 Ashpan 8 Flue Spigot Part Description Visual Aid not to scale Hereford 7 Wood Multifuel AFS1177 AFS1020 AFS1168 AFS009 AFS008 AFS050 AFS010 Hereford 10 Wood Multifuel AFS009 AFS058 AFS010 3 Fire Do...

Page 25: ...xings Per Set 18 Airwash Curved Part Description Visual Aid not to scale Hereford 7 Wood Multifuel AFS1078 AFS1070 AFS1179 AFS1095 AFS1010 AFS047 AFS1144 Hereford 10 Wood Multifuel AFS1009 19 Fire doo...

Page 26: ...Manufacturers decision shall be final If your appliance proves to be defective as a result of faulty materials or workmanship during guarantee we will repair or replace it FREE OF CHARGE as long as t...

Page 27: ...s manual please contact your Hamlet retailer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visits as they will complete the service record chart...

Page 28: ...ked it and it s O K Assembled by Checked by Date of Purchase Name and address of supplier Please ensure installer completes INSTALLATION CHECK LIST details on page 23 of this manual If an add in boile...

Reviews: