background image

™ 

2020/3820

Cordless System

User’s Guide

Summary of Contents for 3820

Page 1: ...2020 3820 Cordless System User s Guide...

Page 2: ...in nor for incidental or consequential damages resulting from the furnishing performance or use of this material This document contains proprietary information which is protected by copyright All righ...

Page 3: ...ce pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radi...

Page 4: ...RF exposure guidelines for body worn operation do not use accessories that contain metallic components and ensure that the device is at least 15mm 0 6 inches from the body Canadian Compliance This Cl...

Page 5: ...Federal Communications Commission FCC Bluetooth Radio Device R TTE Compliance Statement These devices are in conformity with all essential requirements of the R TTE Directive 1999 5 EC This equipment...

Page 6: ...atement T V or GS marked to EN60950 and EN60825 1 C Tick Statement Conforms to AS NZS 3548 C Tick number N10410 Mexico Patents Please refer to the 3820 packaging for patent information Solids and Wate...

Page 7: ...Required Safety Labels 3820SR0C0BE 3820...

Page 8: ...d a n a C c n I s t c u d o r P d l e H d n a H 3 5 1 3 1 Y N s l l a F s e l e t a e n a k S a n i h C n i e d a M 0 4 7 3 5 1 E g n i d n e P s t n e t a P n g i e r o F d n a S U 2 8 6 0 E T I Y R...

Page 9: ...Changing Scanner Name Serially 1 8 Changing Scanner Name via Bar Codes 1 9 Scanner Report 1 10 Application Work Groups 1 10 Application Work Group Selection 1 11 Resetting the Standard Product Default...

Page 10: ...ation Plug Play 1 22 IBM 4683 Ports 5B 9B and 17 Interface 1 23 Connecting the Base with USB 1 24 IBM SurePos 1 25 USB PC or Macintosh Keyboard 1 25 USB HID 1 26 USB Com Port Emulation 1 26 Connecting...

Page 11: ...eeper Volume Good Read 3 1 Beeper Pitch Good Read 3 2 Beeper Duration Good Read 3 2 LED Good Read 3 2 Number of Beeps Good Read 3 3 Good Read Delay 3 3 User Specified Good Read Delay 3 3 Scanner Trigg...

Page 12: ...r Delay 4 5 User Specified Intercharacter Delay 4 5 Interfunction Delay 4 6 Intermessage Delay 4 6 Chapter 5 Data Formatting Data Format Editor Introduction 5 1 To Add a Data Format 5 1 Other Programm...

Page 13: ...t 2 of 5 Industrial Message Length 6 12 Straight 2 of 5 IATA Message Length 6 13 Matrix 2 of 5 6 13 Matrix 2 of 5 Message Length 6 14 Code 11 6 14 Check Digits Required 6 14 Code 11 Message Length 6 1...

Page 14: ...slate 6 25 EAN JAN 8 6 25 EAN JAN 8 Check Digit 6 25 EAN JAN 8 Addenda 6 26 EAN JAN 8 Addenda Required 6 26 EAN JAN 8 Addenda Separator 6 26 MSI 6 27 MSI Check Character 6 27 MSI Message Length 6 28 P...

Page 15: ...fault Settings Current Application Work Group 8 2 Resetting the Standard Product Default Settings All Application Work Groups 8 3 Temporary Visual Xpress Configuration 8 3 Chapter 9 Visual Xpress Visu...

Page 16: ...cations 11 2 3820 Depth of Field 11 3 Chapter 12 Maintenance Maintenance 12 1 Cleaning the Scanner s Window 12 1 Inspecting Cords and Connectors 12 1 Replacing the 2020 5B Interface Cable 12 2 Trouble...

Page 17: ...ort and durability an advanced two way spread spectrum radio Bluetooth wireless technology a wide range of interfaces keyboard wedge wand emulation RS 232 terminals USB and legacy decoders visible and...

Page 18: ...g steps Check to make sure everything you ordered is present Save the shipping container for later storage or shipping Check for damage during shipment Report damage immediately to the carrier who del...

Page 19: ...canner by a rechargeable battery that is integrated in the scanner handle Each scanner is shipped with a battery See Product Specifications beginning on page 11 1 Charging Information The battery is d...

Page 20: ...ill eventually be depleted Replace it after the battery is unable to hold an adequate charge If you are not sure if the battery or charger is working properly send it to Hand Held Products or an autho...

Page 21: ...source only The chart below describes each selection by condition Using a slow charge rate draws less current power from the input power source when the battery is mostly discharged Scan the appropri...

Page 22: ...dless system is set up correctly scan one of the sample bar codes in the back of this manual If the scanner provides a single good read beep and the green LED lights the scanner has successfully linke...

Page 23: ...y scanning the Unlink Scanner bar code See Scanner Modes on page 1 6 Open Link Mode Single Scanner When newly shipped or defaulted to factory settings the base and scanner are not linked By placing a...

Page 24: ...anners linked to one base so that you will be able to control the scanner receiving imaging commands sent from the base The default name for an 3820 is 3820 If you have more than one 3820 linked to a...

Page 25: ...below with the first scanner scan the 1 bar code on the Programming Chart inside the back cover of this manual and scan Save Then scan the Reset bar code and wait for the scanner to re link to the ba...

Page 26: ...oup and may program each scanner independently Visual XPress page 9 1 makes it easy for you to program your system for use with multiple scanners and multiple work groups The scanner keeps a copy of t...

Page 27: ...rogramming selection allows you to assign a scanner to a work group by scanning the bar code below You may then program the settings e g beeper volume prefix suffix data formatter that your applicatio...

Page 28: ...se on page 1 6 for additional information Note If your scanner is in multiple scanner mode and you scan either the current or all application group default bar code you will hear up to 30 seconds of b...

Page 29: ...oth devices other than the 2020 5B base Changing Bluetooth PIN Code Some devices require a PIN code as part of the Bluetooth security features Your scanner s default PIN is 1234 which you may need to...

Page 30: ...your application Data Accumulation Mode Scan the bar codes below to turn data accumulation batch mode on and off If data accumulation mode is on bar code data is stored when the scanner is out of rang...

Page 31: ...eration Red Flash None Battery low Green Flash 1 beep Successful communication or linking Red blinking 3 beeps Failed communication Menu Operation Green Flash 2 beeps Successful menu change Red blinki...

Page 32: ...ording to the Charge Status Indicator table above The base can be powered by the Host parasitic power mode If the base is in parasitic power mode without the 9VDC power source the base will still func...

Page 33: ...are automatically detects the scanner and links it to the base depending on the selected link mode Scanner Is Out of Range The cordless scanner is in communication with its base even when it is not tr...

Page 34: ...base indicates that the data sent was received by the host The cordless scanner recognizes data acknowledgement ACK from the base unit If it cannot be determined that the data has been properly sent t...

Page 35: ...wedge interface See Keyboard Wedge Connection on page 1 21 6 Verify the base operation by scanning a bar code from the Sample Symbols in the back of this manual Note Without using the 9 volt external...

Page 36: ...g line on the symbol Resetting the Standard Product Defaults If you aren t sure what programming options are in your scanner or you ve changed some options and want the factory settings restored scan...

Page 37: ...s operation of the scanner in parallel with the integral keyboard The following Laptop Direct Connect bar code selects terminal ID 03 programs a carriage return CR suffix and turns on Emulate External...

Page 38: ...s all other symbologies to Code 39 The Wand Emulation Plug Play Code 39 Format bar code below sets the terminal ID to 61 The Wand Emulation Plug Play Same Code Format bar code sets the terminal ID to...

Page 39: ...ollowing suffixes for each symbology Suffixes programmed for Code 128 with IBM 4683 Port 5B IBM 4683 Port 9B HHBCR 1 and IBM 4683 Port 17 Interfaces Suffixes programmed for Code 128 with IBM 4683 Port...

Page 40: ...y scanning a bar code from the Sample Symbols in the back of this manual For additional USB programming and technical information refer to Hand Held Products USB Application Note available at www hand...

Page 41: ...PC or Macintosh Keyboard Scan one of the following codes to program the 3820 for USB PC Keyboard or USB Macintosh Keyboard Scanning these codes adds a CR and LF along with selecting the terminal ID U...

Page 42: ...will need to download a driver from the Hand Held Products website www handheld com The driver will use the next available Com Port number Apple Macintosh computers recognize the scanner as a USB CDC...

Page 43: ...g serial cable from the computer 3 Connect the appropriate interface cable to the base Note For the base to work properly you must have the correct cable for your type of computer 4 Plug the serial co...

Page 44: ...ge terminal ID use the serial terminal ID 050 and follow the instructions on page 2 1 Make sure that all of the communication parameters match on all of the connected devices Choosing Both sends scann...

Page 45: ...erminal ID Scan Save to save your selection For example an IBM AT terminal has a Terminal ID of 003 You would scan the Terminal ID bar code then 0 0 3 from the Programming Chart inside the back cover...

Page 46: ...008 IBM 122 key 3180 024 IBM 122 key 3180 data entry keyboard 114 IBM DOS V 106 key PC Workstation 102 IBM SurePOS USB Hand Held Scanner 128 IBM SurePOS USB Tabletop Scanner 129 IBM Thinkpad 360 CSE...

Page 47: ...s rather than scanning the terminal ID listed in this table Telex 122 key 078 078A 79 80 191 196 1191 1192 1471 1472 1476 1477 1482 1483 046 USB PC Keyboard 124 USB Mac Keyboard 125 USB Com Port 130 U...

Page 48: ...gram the keyboard for your country As a general rule the following characters are supported but need special care for countries other than the United States United States Brazil Czech Republic Denmark...

Page 49: ...2020 3820 User s Guide 2 5 Keyboard Country continued Latin America Norway Poland Portugal Romania Russia SCS Slovakia Italy Netherlands Dutch Spain Sweden Switzerland German Turkey Q U K Turkey F...

Page 50: ...Lock is used when you normally have the Caps Lock key on Shift Lock is used when you normally have the Shift Lock key on not common to U S keyboards Automatic Caps Lock is used if you change the Caps...

Page 51: ...ode On The scanner sends key combinations for ASCII control characters for values 00 1F Refer to Keyboard Function Relationships page 7 1 for CTRL ASCII Values Default Off Turbo Mode The scanner sends...

Page 52: ...rface cable to the base Note For the base to work properly you must have the correct cable for your type of terminal computer 3 Plug the serial connector into the serial port on your computer Tighten...

Page 53: ...terface bar code programs the scanner for an RS 232 interface at 115 200 baud parity none 8 data bits 1 stop bit and adds a suffix of a CR LF RS 232 Baud Rate Baud Rate sends the data from the scanner...

Page 54: ...For applications which require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking character bit...

Page 55: ...cators emitted from the source scanner Turning the Host ACK selection on configures the cordless system scanners to respond to commands from the host system The following criteria must be met for the...

Page 56: ...anner reads a code and sends data to the base host system No audible or visual indication is emitted until you receive an escape command The scanner read illumination goes out upon a successful read S...

Page 57: ...ate green LED for two seconds followed by at least 500 mSecs dark time when multiple blinks ESC 3 Illuminate green LED for five seconds followed by at least 500 mSecs dark time when multiple blinks ES...

Page 58: ...nging the terminal ID Please refer to Wand Emulation Plug Play on page 1 22 for further information In Wand Emulation mode the scanner decodes the bar code then sends data in the same format as a wand...

Page 59: ...s limited by the terminal s ability to receive data without dropping characters Default 25 inches second Wand Emulation Polarity The Polarity can be sent as standard with black bars high or reversed w...

Page 60: ...scanner s idle state to match the idle state for the device to which the scanner is connected Default Idle High Wand Emulation Data Block Size This transmits the data in smaller blocks to prevent buf...

Page 61: ...a computed check character is added at the end of the entire message The check character is the character which when Exclusive OR d with every preceding character of the message yields a result of 0x...

Page 62: ...2 18 2020 3820 User s Guide...

Page 63: ...to a good read Turning this option off only turns off the beeper response to a good read indication All error and menu beeps are still audible Default On Beeper Volume Good Read The beeper volume cod...

Page 64: ...d Default Medium Beeper Duration Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read Default Normal LED Good Read The LED indicator can be programmed On...

Page 65: ...n the bar code below and then scan a digit 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Default One Good Read Delay This sets the minimum amount of...

Page 66: ...ger Mode Use this selection to set a time out in milliseconds of the scanner s trigger when using serial commands to trigger the scanner Once the scanner has timed out you can activate the scanner eit...

Page 67: ...ode pull the trigger to power the unit back up There will be a set of power up beeps and a delay of up to a few seconds for the radio to join The scanner will then be ready to use Automatic Trigger Th...

Page 68: ...ck cover and Save Default 5 000 ms Reread Delay This sets the time period before the scanner can read the same bar code a second time Setting a reread delay protects against accidental rereads of the...

Page 69: ...be within the window to be decoded or output by the scanner To change the left or right edge of the centering window scan Centering On then scan one of the following bar codes Then scan the percent y...

Page 70: ...in whatever order your application requires regardless of the order in which the bar codes are scanned Reading the Default Sequence symbol programs the scanner to the Universal values shown below The...

Page 71: ...Program ming Chart inside the back cover of this manual to read the alphanumeric combination that represents the ASCII characters 99 is the Universal num ber indicating all characters 5 End Output Se...

Page 72: ...e 39 1st Code 128 2nd and Code 93 3rd as shown below Note Code 93 must be enabled to use this example You would set up the sequence editor with the following command line SEQBLK62999941FF6A999942FF699...

Page 73: ...ted characters as part of the length If you use the example on page 3 10 but assume a CR suffix and specific code lengths you would use the following command line SEQBLK62001241FF6A001342FF69001243FF...

Page 74: ...canner sends an NR to the host if you pull and release the trigger without reading a code e g bad bar code If No Read is turned Off the NR will not be sent to the host If you want a different notation...

Page 75: ...to Keep In Mind It is not necessary to build a message string The selections in this chapter are only used if you wish to alter the default settings Default prefix None Default suffix None A prefix or...

Page 76: ...character Step 7 To add the Code I D scan 5 C 8 0 To add AIM I D scan 5 C 8 1 To add a backslash scan 5 C 5 C Note To add a backslash as in Step 7 you must scan 5C twice once to create the leading bac...

Page 77: ...ex value from the Symbology Chart included in the Appendix A for the symbology from which you want to clear the pre fix or suffix Step 3 Scan the 2 digit hex value from the Programming Chart inside th...

Page 78: ...is in keyboard wedge mode the scan code is converted to a key code before it is transmitted Default Enable Intercharacter Interfunction and Intermessage Delays Some terminals drop information characte...

Page 79: ...r Specified Intercharacter Delay An intercharacter delay of up to 495 milliseconds may be placed after the transmission of a particular character of scanned data Scan the Delay Length bar code below t...

Page 80: ...g Chart inside the back cover of this manual Intermessage Delay An intermessage delay of up to 495 milliseconds may be placed between each scan transmission Scan the Intermessage Delay bar code below...

Page 81: ...ength 6 Universal Term ID Actual Code ID Universal Length 7 Universal Term ID Universal Code ID Actual Length 8 Universal Term ID Universal Code ID Universal Length If you have changed data format set...

Page 82: ...e clearing an alternate format scan 1 2 or 3 depending on the alternate format you are clearing Scan the Terminal Type refer to the Supported Terminals Chart on page 2 2 Code I D refer to the Symbolog...

Page 83: ...ntax F8xx xx stands for the hex value for an ASCII code see ASCII Conversion Chart Code Page 1252 on page A 2 F9 Search back for xx character from current cursor position leaving cursor pointing to xx...

Page 84: ...are character in current cursor position to the character xx If char acters are equal increment cursor If characters are not equal no format match Syntax FExx xx stands for the hex value for an ASCII...

Page 85: ...t capability to scan one bar code using a different data format than your primary format When data formats are programmed see page 5 1 you must input whether you are programming the primary format or...

Page 86: ...5 6 2020 3820 User s Guide...

Page 87: ...icular symbology scan All Symbologies Off followed by the On symbol for that particular symbology All Symbologies Korea Post Code China Post Code Matrix 2 of 5 Codabar UPC A EAN 13 with Extended Coupo...

Page 88: ...duce the chances of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min leng...

Page 89: ...characters are created using different modulos You can program the scanner to read only Codabar bar codes with Modulo 16 check characters Default No Check Character No Check Character indicates that t...

Page 90: ...ks for a Codabar symbol having a D start character adjacent to a symbol having a D stop character In this case the two messages are concatenated into one with the D characters omitted Default On Selec...

Page 91: ...and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 Code 39 Default All Code 39 Settings Code 39 Code 39 Start Stop Characters Start Stop characters identify the leading and trailing ends of...

Page 92: ...the scanned data When Check Character is set to Validate and Transmit the scanner only reads Code 39 bar codes printed with a check character and will transmit this character at the end of the scanned...

Page 93: ...a space excluding the start and stop symbols and does not immediately transmit the data The scanner stores the data in the order in which the bar codes are read deleting the first space from each The...

Page 94: ...period respectively Character pairs P through Y decode as 0 through 9 NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3 C C S...

Page 95: ...se scan the bar code below select the code page with which the bar codes were created from the chart Code Page Mapping of Printed Bar Codes on page A 4 and scan the value and the SAVE bar code from th...

Page 96: ...nly reads Interleaved 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit Interleaved 2 of 5 Message Length Scan the bar code...

Page 97: ...eived does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the...

Page 98: ...f 5 Industrial Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Ma...

Page 99: ...e bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Matrix 2 of 5 Defaul...

Page 100: ...additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Code 11 Default All Code 11 Settings Code 11 Check Digits Required This option sets whether 1 or 2 check di...

Page 101: ...bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Code 128 Default All C...

Page 102: ...Code 128 Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 0 80 Minimum Default 0 Maximum...

Page 103: ...lt All Telepen Settings Telepen Telepen Output Using AIM Telepen Output the scanner reads symbols with start stop pattern 1 and decodes them as standard full ASCII start stop pattern 1 When Original T...

Page 104: ...r additional information Minimum and Maximum lengths 1 60 Minimum Default 1 Maximum Default 60 UPC A Default All UPC A Settings UPC A UPC A Check Digit This selection allows you to specify whether the...

Page 105: ...nsmit it Default On UPC A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC A data Default Off for both 2 Digit and 5 Digit Addenda UPC A Addenda Required When Addenda Required i...

Page 106: ...etween the data from the bar code and the data from the addenda When turned off there is no space Default On UPC A EAN 13 with Extended Coupon Code Use the following codes to enable or disable UPC A a...

Page 107: ...system use the UPC E1 selection Default On UPC E0 and Off UPC E1 UPC E0 and UPC E1 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off UPC E0 and UPC E1 Addenda Requir...

Page 108: ...ff there is no space Default On UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not Default On UPC E0 Number System The numeric...

Page 109: ...both 2 Digit and 5 Digit Addenda EAN JAN 13 Default All EAN JAN Settings EAN JAN 13 EAN JAN 13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end...

Page 110: ...Addenda Required is set to on the scanner will only read EAN JAN 13 bar codes that have addenda Default Not Required EAN JAN 13 Addenda Separator When this feature is on there is a space between the...

Page 111: ...ISBN Translate This selection causes EAN 13 Bookland symbols to be translated into their equivalent ISBN number format Default Off EAN JAN 8 Default All EAN JAN 8 Settings EAN JAN 8 EAN JAN 8 Check D...

Page 112: ...Addenda Required is set to on the scanner will only read EAN JAN 8 bar codes that have addenda Default Not Required EAN JAN 8 Addenda Separator When this feature is on there is a space between the dat...

Page 113: ...k Character is set to Validate and Transmit the scanner will only read MSI bar codes printed with the specified type check character and will transmit this character at the end of the scanned data Whe...

Page 114: ...mum Default 4 Maximum Default 48 Plessey Code Default All Plessey Code Settings Plessey Code Plessey Message Length Scan the bar codes below to change the message length Refer to Message Length on pag...

Page 115: ...2020 3820 User s Guide 6 29 RSS 14 Default All RSS 14 Settings RSS 14 RSS Limited Default All RSS Limited Settings RSS Limited On Off On Off...

Page 116: ...lengths 4 74 Minimum Default 4 Maximum Default 74 EAN UCC Emulation The scanner can automatically format the output from any EAN UCC data carrier to emulate what would be encoded in an equivalent UCC...

Page 117: ...one data carrier type Default EAN UCC Emulation Off China Post Code Default All China Post Code Settings China Post Code China Post Message Length Scan the bar codes below to change the message length...

Page 118: ...a Post Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum De...

Page 119: ...th Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 On Off A a...

Page 120: ...rioptic Code must be off Codablock F Default All Codablock F Settings Codablock F Codablock F Message Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 f...

Page 121: ...age Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 0 160 Minimum Default 1 Maximum Default 160...

Page 122: ...ge Length Scan the bar codes below to change the message length Refer to Message Length on page 6 2 for additional information Minimum and Maximum lengths 1 81 Minimum Default 1 Maximum Default 81 On...

Page 123: ...at can be used with the scanner Refer to page 2 7 enable Control ASCII mode Function Code HEX ASCII Value Full ASCII CTRL NUL 00 2 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08...

Page 124: ...column 6 apply to US only The following chart indicates the equivalents of these five characters for different countries Country Codes United States 6 Belgium 6 Scandinavia 8 9 6 France 8 6 Germany 6...

Page 125: ...nter New Line BS 08 Reserved Reserved F16 HT 09 Tab Tab F17 LF 0A Reserved Reserved F18 VT 0B Tab Tab Tab Field Forward FF 0C Delete Delete Delete CR 0D CR Enter CR Enter Field Exit New Line SO 0E Ins...

Page 126: ...A F18 Reserved VT 0B Tab Field Forward Field Forward FF 0C Delete Delete CR 0D Field Exit New Line SO 0E Insert Insert SI 0F Clear Erase DLE 10 Error Reset Error Reset DC1 11 Home Reserved DC2 12 Prin...

Page 127: ...A BEL 07 New Line New Line New Line BS 08 N A N A N A HT 09 Tab Tab Tab LF 0A N A N A N A VT 0B Tab Tab Tab FF 0C N A N A Delete CR 0D New Line New Line New Line SO 0E N A N A Insert SI 0F Escape Esca...

Page 128: ...04 ALT break ENQ 05 CNTRL make ACK 06 CNTRL break BEL 07 RETURN BS 08 APPLE make HT 09 TAB LF 0A APPLE break VT 0B TAB FF 0C Del CR 0D RETURN SO 0E Ins Help SI 0F ESC DLE 10 F11 DC1 11 Home DC2 12 Prn...

Page 129: ...l symbologies This is a temporary setting that will be removed when the unit is reset For instructions on how to reset your scanner refer to Reset Scanner page 8 1 Reset Scanner Scanning this bar code...

Page 130: ...ar code below to determine the address of the base you are using Resetting the Standard Product Default Settings Current Application Work Group If you aren t sure what programming options are in your...

Page 131: ...ress bar code to temporarily configure the imager for Visual Xpress settings Refer to Visual Xpress on page 10 1 for additional information about Visual Xpress Note Connect the imager using RS 232 cab...

Page 132: ...8 4 2020 3820 User s Guide...

Page 133: ...es and display the bar code data in a window Scan Data lets you send serial commands to the imager and receive imager response that can be seen in the Scan Data window The data displayed in the Scan D...

Page 134: ...ss 5 When prompted select Save File and save the files to the c windows temp directory 6 Once you have finished downloading the file exit the web site 7 Using Explorer go to the c windows temp file an...

Page 135: ...ws that appear on the screen Menu Command Syntax Menu commands have the following syntax spaces have been used for clarity only Prefix Name Tag SubTag Data SubTag Data Tag SubTag Data Storage Prefix T...

Page 136: ...r the setting s The de vice s response uses a dash to indicate a continuous range of values A pipe separates items in a list of non continuous val ues Name Field Usage Optional This command returns th...

Page 137: ...combination e g an entry for a minimum message length of 100 when the field will only accept 2 characters When responding the device echoes back the command sequence with the status character inserted...

Page 138: ...characters and the Default setting DFT has no value Trigger Commands You can activate and deactivate the scanner with serial trigger commands First the scanner must be put in Manual Serial Trigger Mod...

Page 139: ...se on page 1 6 for additional information Note If your scanner is in multiple scanner mode and you scan either the current or all application group default bar code you will hear up to 30 seconds of b...

Page 140: ...nner Name Scanner Name BT_NAM 1 9 Scanner Report Scanner Report RPTSCN 1 10 Application Work Group Selections Group 0 GRPSEL0 1 11 Group 1 GRPSEL1 1 11 Group 2 GRPSEL2 1 11 Group 3 GRPSEL3 1 11 Group...

Page 141: ...1 14 Scanner Alarm Type BT_ORW 1 14 Data Accumulation Mode On BATENA1 1 14 Off BATENA0 1 14 Factory Default Settings Default DEFALT 1 20 Terminal Interfaces Terminal ID 003 TERMID 2 2 Selection Setti...

Page 142: ...merica KBDCTY14 2 5 Netherlands Dutch KBDCTY11 2 5 Norway KBDCTY9 2 5 Poland KBDCTY20 2 5 Portugal KBDCTY13 2 5 Romania KBDCTY25 2 5 Russia KBDCTY26 2 5 SCS KBDCTY21 2 5 Slovakia KBDCTY22 2 5 Spain KB...

Page 143: ...D3 2 9 4800 BPS 232BAD4 2 9 9600 BPS 232BAD5 2 9 19200 BPS 232BAD6 2 9 38400 BPS 232BAD7 2 9 57600 BPS 232BAD8 2 9 115200 BPS 232BAD9 2 9 Word Length Data Bits Stop Bits and Parity 7 Data 1 Stop Parit...

Page 144: ...2 15 150 WNDSPD5 2 15 200 WNDSPD6 2 15 Wand Emulation Polarity Black High WNDPOL0 2 15 White High WNDPOL1 2 15 Wand Emulation Idle Idle Low WNDIDL0 2 16 Idle High WNDIDL1 2 16 Wand Emulation Data Blo...

Page 145: ...RPT 3 3 Good Read Delay No Delay DLYGRD0 3 3 Short Delay 500 ms DLYGRD500 3 3 Medium Delay 1000 ms DLYGRD1000 3 3 Long Delay 1500 ms DLYGRD1500 3 3 User Specified Good Read Delay Range 0 30 000 ms DLY...

Page 146: ...Output Sequence Required SEQ_EN2 3 10 On Not Required SEQ_EN1 3 10 Off SEQ_EN0 3 10 Multiple Symbols On SHOTGN1 3 12 Off SHOTGN0 3 12 No Read On SHWNRD1 3 12 Off SHWNRD0 3 12 Video Reverse On VIDREV1...

Page 147: ...rnate Data Formats 1 VSAF_1 5 5 2 VSAF_2 5 5 3 VSAF_3 5 5 Symbologies All Symbologies All Symbologies Off ALLENA0 6 1 All Symbologies On ALLENA1 6 1 Codabar Default All Codabar Settings CBRDFT 6 3 Cod...

Page 148: ...320 6 8 On C39B321 6 8 Code 39 Full ASCII Off C39ASC0 6 8 On C39ASC1 6 8 Interleaved 2 of 5 Default All Interleaved 2 of 5 Settings I25DFT 6 9 Interleaved 2 of 5 Off I25ENA0 6 9 On I25ENA1 6 9 Interle...

Page 149: ...FT 6 13 Matrix 2 of 5 Off X25ENA0 6 13 On X25ENA1 6 13 Matrix 2 of 5 Message Length Minimum 1 80 4 X25MIN 6 14 Maximum 1 80 80 X25MAX 6 14 Code 11 Default All Code 11 Settings C11DFT 6 14 Code 11 Off...

Page 150: ...UPC A Settings UPADFT 6 18 UPC A Off UPAENA0 6 18 On UPAENA1 6 18 UPC A Check Digit Off UPACKX0 6 18 On UPACKX1 6 18 UPC A Number System Off UPANSX0 6 19 On UPANSX1 6 19 UPC A 2 Digit Addenda Off UPA...

Page 151: ...Default All EAN JAN 13 Settings E13DFT 6 23 EAN JAN 13 Off E13ENA0 6 23 On E13ENA1 6 23 EAN JAN 13 Check Digit Off E13CKX0 6 23 On E13CKX1 6 23 EAN JAN 13 2 Digit Addenda Off E13AD20 6 24 On E13AD21 6...

Page 152: ...SIENA1 6 27 MSI Check Character Validate Type 10 but Don t Transmit MSICHK0 6 27 Validate Type 10 and Transmit MSICHK1 6 27 MSI Message Length Minimum 4 48 4 MSIMIN 6 28 Maximum 4 48 48 MSIMAX 6 28 Pl...

Page 153: ...6 31 Maximum 2 80 80 CPCMAX 6 31 Korea Post Code Default All Korea Post Code Settings KPCDFT 6 32 Korea Post Code Off KPCENA0 6 32 On KPCENA1 6 32 Korea Post Code Msg Length Minimum 2 80 4 KPCMIN 6 3...

Page 154: ...ll Code 16K Settings 16KDFT 6 35 Code 16K Off 16KENA0 6 35 On 16KENA1 6 35 Code 16K Minimum 0 160 1 16KMIN 6 35 Maximum 0 160 160 16KMAX 6 35 Code 49 Default All Code 49 Settings C49DFT 6 35 Code 49 O...

Page 155: ...Horizontal Velocity 2 inches 5 cm per second Scan Contrast 20 minimum Battery Lithium Ion 3 6 Volt 1600 mAHr minimum Battery Capacity Standby Heavy Usage 1 scan per second 20 hours 12 hours Storage 5...

Page 156: ...not charge 9 Volt DC Barrel 100 850mA 12 Volt Host 100 825mA Charge Rate 41 F to 104 F 5 C to 40 C 9 Volt DC Barrel external power Maximum 4 hours full charge for fully discharged battery Temperature...

Page 157: ...ield no ambient lighting 13 mil 100 UPC 1 in 2 5 cm 24 in 61 cm 7 5 mil Code 39 4 in 10 cm 14 in 36 cm 10 mil Code 39 2 in 5 cm 18 in 46 cm 13 mil Code 39 1 in 2 5 cm 24 in 61 cm 15 mil Code 39 1 in 2...

Page 158: ...Pinouts Keyboard Wedge 10 Pin RJ41 Modular Plug connects to the base 1 2 Cord shield 3 Tied to supply power 4 Supply ground 5 Terminal clock 6 Terminal data 7 Supply power input Refer to tables on pag...

Page 159: ...he base 1 2 Cord shield 3 Prog 1 Tied to supply power for primary cable 4 Supply ground 5 6 Bar code data output 7 Supply power input Refer to tables on page 11 2 8 9 10 Bar code data output Supply po...

Page 160: ...r Plug connects to the base 1 2 Cord shield 3 Prog 1 Tied to supply power for primary cable 4 Supply ground 5 Receive data Serial data to scanner 6 Transmit data Serial data from scanner 7 Supply powe...

Page 161: ...2020 3820 User s Guide 11 7 Standard Cable Pinouts USB 10 Pin Modular Plug connects to the base 1 2 Data 3 Tied to supply power 4 Supply ground 5 6 7 5 volt supply power input 8 9 10 Data...

Page 162: ...11 8 2020 3820 User s Guide...

Page 163: ...used rinse with a clean lens tissue dampened with water only The base and scanner s housing may also be cleaned the same way Inspecting Cords and Connectors Inspect the base s interface cable and con...

Page 164: ...3820 Battery 1 Remove the screw on the end cap 2 Remove the battery from the handle 3 Insert battery 4 Replace end cap and screw Troubleshooting Base Note Please visit the Services and Support sectio...

Page 165: ...ich the scanner connects Is the bar code displayed but not entered into the application The bar code is displayed on the host device correctly but you still have to press a key to enter it the Enter R...

Page 166: ...still can t read the sample bar codes scan All Symbologies on page 6 1 If you aren t sure what programming options have been set in the base or if you want the factory default settings restored scan...

Page 167: ...phone 800 782 4263 option 3 Fax 704 566 6015 E mail naservice handheld com Am rica Latina Hand Held Products Am rica Latina Tel fono 704 998 3998 opci n 8 opci n 4 Fax 239 263 9689 E mail laservice ha...

Page 168: ...If you need assistance installing or troubleshooting please call your Distributor or the nearest Hand Held Products technical support office North America Canada Telephone 800 782 4263 option 4 8 a m...

Page 169: ...the purchaser or other party B excessive voltage or current supplied to or drawn from the interface connections C static electricity or electro static discharge D operation under conditions beyond the...

Page 170: ...TIONS ON LIABILITY SHALL REMAIN IN FULL FORCE AND EFFECT EVEN WHEN HAND HELD PRODUCTS MAY HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES LOSSES OR DAMAGES SOME STATES PROVINCES OR COUNTRIES DO...

Page 171: ...ID China Post Q X0 51 Korea Post X0 3F Codabar a Fm 61 Matrix 2 of 5 m X0 6D Codablock F q Om 71 MSI g Mm 67 Code 11 h Hm 68 No Read 9C Code 16K o Km 6F Plessey Code n P0 6E Code 39 b Am 62 PosiCode W...

Page 172: ...29 73 49 l 105 69 i 10 0A LF 42 2A 74 4A J 106 6A j 11 0B VT 43 2B 75 4B K 107 6B k 12 0C FF 44 2C 76 4C L 108 6C l 13 0D CR 45 2D 77 4D M 109 6D m 14 0E SO 46 2E 78 4E N 110 6E n 15 0F SI 47 2F 79 4F...

Page 173: ...139 8B 171 AB 203 CB 235 EB 140 8C 172 AC 204 CC 236 EC 141 8D 173 AD 205 CD 237 ED 142 8E 174 AE 206 CE 238 EE 143 8F 175 AF 207 CF 239 EF 144 90 176 B0 208 D0 240 F0 145 91 177 B1 209 D1 241 F1 146...

Page 174: ...ion is available for Code 39 Code 93 and Code 128 Code Page Standard Description 1 CP ISO646 2 Default ISO 2022 Automatic National Replacement Characters 3 CP Binary 82 ISO 2022 11 Swe Swedish Replace...

Page 175: ......

Page 176: ......

Page 177: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 1234567890 Code 128 9 780330 290951 654 EAN 8 3210 5 456123 8 0 UPC E...

Page 178: ...Sample Symbols Code 93 123456 9 Straight 2 of 5 Industrial 123456 Matrix 2 of 5 6543210 RSS 14 01 00123456789012 Code 39 Codabar BC321 A13579B...

Page 179: ...ogramming Chart A C Save B Discard F E D Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save 0 2 6 1 7 5 4 3 8...

Page 180: ...Hand Held Products Inc 700 Visions Drive P O Box 208 Skaneateles Falls NY 13153 0208 3820 UG Rev A 5 06...

Reviews: