7610.718.14       4/02

FILTER

MONITOR

INSTRUCTION MANUAL

SERVICE DEPARTMENT: (724) 746-1100

Introduction

The Filter Monitor continuously monitors the differential
pressure (pressure drop) across a filter and alerts the
operator of the need for element replacement when
any of three operating criteria are met:

1. Maximum elapsed time (service interval) before

change-out - operator alerted when user selected
time period elapses.

2. Maximum allowable differential pressure - operator

alerted when user selected maximum differential
pressure occurs.

3. Intelligence  - operator alerted when the optimum time

to replace the element(s) has occurred. The Monitor
calculates this using the element type, the initial charac-
teristic pressure drop and historical pressure drop data.

Grade 9

3

0.21

0.20

B

Grade 7

4

0.28

0.28

C

Grade 6

4

0.28

0.28

D

Grade 5

5

0.35

0.34

E

Grade 3

6

0.42

0.41

F

Grade 1

3

0.21

0.20

G

Recommended Settings for HF Series Filters

1. Maximum time before element replacement:  Grades 9, 7, 6, 5, 3, - 12 MONTHS;

Grades 1 - 6 MONTHS;

2. Maximum pressure differential:

Programming Instructions

(Short version - for complete instructions see page 3)
1. To begin programming,  press and hold ENTER button

for 3 seconds.

2. Press and hold the scroll button to input maximum

service interval (1 to 15 months) - press ENTER.

3. Press and hold the scroll button to select pressure unit

of measure (KG/CM

2

,PSI, or BAR). - press ENTER.

4. Press and hold the scroll button to input  maximum

pressure drop (0.01 to 1.00 KG/CM

2  

or BAR;  0.1 to

15 PSI) Use Left Shift and Right Shift buttons to select
advance rate (e.g. by ones, tenths, or hundredths) -
press ENTER.

 5. Press and hold the scroll button to select the element

letter type (see chart above) - press ENTER.

 6. Select Initalize or Run mode.

Initalize - Scroll until initial pressure drop and run icons
are displayed. (To be selected during initial installation
and element charge out).

      Run -Scroll until run icon only is displayed. (To be

selected if Monitor is reprogrammed without changing
the element).

 7. Press ENTER  to start program.

HF Series

Setting

Element

Grade

psid

kgf/cm

2

bar

Letter Type

INITIAL     P ICON 

SHIFT LEFT 
BUTTON

SHIFT RIGHT 
BUTTON

SCROLL
BUTTON

ENTER
BUTTON

OPERATOR 
ALERT LIGHT
(RED LED)

LIQUID
CRYSTAL
DISPLAY

RUN ICON