Instruction Manual

HI 93530 - HI 93531
HI 93532 - HI 93551

HI 935005 - HI 935006

HI 935007

Microprocessor-based

Thermocouple Thermometers

ins rum n s

°C

°F

MEM-

HOLD

HI

MR

K-THERMOCOUPLE

THERMOMETER

HI 93531

LO

OFF

ON

°C

h t t p : / / w w w . h a n n a c a n . c o m

These Instruments are in

Compliance with the CE Directives

MANK93R3

04/98

h t t p : / / w w w . h a n n a c a n . c o m

PRINTED IN

ITALY

Summary of Contents for HI 93530

Page 1: ...icroprocessor based Thermocouple Thermometers ins rum ns C F MEM HOLD HI MR K THERMOCOUPLE THERMOMETER HI 93531 LO OFF ON C h t t p w w w h a n n a c a n c o m These Instruments are in Compliance with...

Page 2: ...935006 10 Functional Description and Specifications of HI 935007 11 Operational Guide 12 Display Codes Guide 19 Battery Replacement 20 Calibration 20 Shockproof Rubber Boots 21 Accessories 22 Warrant...

Page 3: ...s accurate com pensation for drifts in the measurement cir cuit and the reference junction All Hanna Instruments meters are warranted for two years against defects in workman ship and materials when u...

Page 4: ...935005 only Low battery detection All these functions are easily accessible through the keypad Self explanatory symbols are used to re mind the user of the operating mode or condition Hanna manufactur...

Page 5: ...optional seepages22 25 Battery 9V 100 hours of continuous use Environment 0 to 50 C 32 to 122 F 95 RH Dimensions 143x80x38mm 5 6x3 2x1 5 Weight 320 g 11 3 oz ins rum ns C F HOLD K THERMOCOUPLE THERMO...

Page 6: ...nal seepages22 25 Battery 9V 100 hrs of continuous use Environment 0 to 50 C 32 to 122 F 95 RH Dimensions 143x80x38mm 5 6x3 2x1 5 Weight 320 g 11 3 oz FUNCTIONAL DESCRIPTION AND SPECIFICATIONS OF HI 9...

Page 7: ...ry 9V 100 hrs of continuous use Environment 0 to 50 C 32 to 122 F 95 RH Dimensions 143x80x38mm 5 6x3 2x1 5 Weight 320g 11 3oz FUNCTIONAL DESCRIPTION AND SPECIFICATIONS FOR HI 93532 ins rum ns 0 1 1 T1...

Page 8: ...be K J and T thermocouple optional for K thermocouple see pages 22 25 Battery 9V 100 hrs of continuous use Environment 0 to 50 C 32 to 122 F 95 RH Dimensions 143x80x38mm 5 6x3 2x1 5 Weight 320 g 11 3...

Page 9: ...38mm 5 6x3 2x1 5 Weight 320 g 11 3 oz CALIBRATION All Hanna Instruments thermometers have been accurately pre calibrated at the factory It is generally recommended to have all ther mometers recalibrat...

Page 10: ...laced HI935005 HI935006 and HI935007 Er The probe is not connected to the instrument or the reading is out of range Eb Weak battery needs to be replaced HI93530 HI93531 HI93551 HI935005 HI935007 C The...

Page 11: ...320 g 11 3 oz LOW BATTERY DETECTION When the battery is low the user is prompted by the ap pearance of the word BAT for HI 93530 HI 93531 HI93532 HI93551 or Eb for HI935005 HI935006 and HI 935007 to...

Page 12: ...30 HI93531 HI93532 HI93551 If the probe is not plugged in the display will show For HI935005 and HI935006 If the probe is not plugged in the display will show Er To switch your thermometer off press O...

Page 13: ...1 d e g r e e resolution Press ON OFF again to change the resolution to 0 1 C or 0 2 F C C C F F ON OFF C MEMORY FUNCTION HI93531 and HI93532 only The memory hold function is activated by MEM HOLD The...

Page 14: ...temperatures are monitored throughout a continuous measur ing process HOLD M HOLD HOLD HOLD The values may be recalled or cleared at any time during the measurement Check the highest or lowest measure...