background image

w w w . h a n n a i n s t . c o m

WARRANTY

HI 98311

 and 

HI 98312

 are 

warranted for one

year

 against defects in workmanship and materials

when used for their intended purpose and maintained
according to instructions. 

The probe is warranted

for a period of six months

. This warranty is limited

to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack
of prescribed maintenance are not covered.
If service is required, contact the dealer from whom
you purchased the instrument. If under warranty,
report the model number, date of purchase, serial
number and the nature of the failure. If the repair is
not covered by the warranty, you will be notified of
the charges incurred. If the instrument is to be re-
turned to Hanna Instruments, first obtain a Returned
Goods Authorization Number from the Customer
Service department and then send it with shipment
costs prepaid. When shipping any instrument, make
sure it is properly packaged for complete protection.

All rights are reserved. Reproduction in whole or in
part is prohibited without the written consent of the
copyright owner, Hanna Instruments.

Instruction Manual

HI 98311 • HI 98312

Waterproof

EC/TDS/Temperature Testers

Remove the instrument from the packing material and
examine it carefully. If any damage has occurred
during shipment, immediately notify your Dealer or
the nearest Hanna Customer Service Center.
Each meter is supplied with:
• 

HI 73311

 EC/TDS probe

• 

HI 73128

 probe removal tool

• batteries (4 x 1.5V) and instructions

Note

: Conserve all packing material until the instru-

ment has been observed to function correctly.
Any defective item must be returned in its
original packing.

PRELIMINARY EXAMINATION

HI 98311

 and 

HI 98312

 are waterproof EC/TDS and

temperature meters. The housing has been completely
sealed against humidity and designed to float.
All EC/TDS readings are automatically temperature
compensated (ATC), and temperature values can be
displayed in °C or °F units.
The EC/TDS conversion factor (CONV) is selectable by
the user, as well as the temperature compensation
coefficient 

β

 (BETA).

The meters can be calibrated at one point.
Measurements are highly accurate with a unique
stability indicator right on the LCD.
A low battery symbol warns the user when the batter-
ies are to be replaced. In addition the Battery Error
Prevention System (BEPS) avoids erroneous reading
caused by low voltage level by turning the meter off.
The 

HI 73311

 EC/TDS probe, supplied with the

meter, is interchangeable and can be easily replaced
by the user.
The stainless steel encapsulated temperature sensor
facilitates faster and more accurate temperature mea-
surement and compensation.

GENERAL DESCRIPTION

FUNCTIONAL DESCRIPTION

Recommendations for Users

Before using this product, make sure that it is entirely suit-
able for the environment in which it is used. Operation of
this instrument in residential areas could cause unaccept-
able interferences to radio and TV equipment.
Avoid touching the probes at all times.
Any variation introduced by the user to the supplied equip-
ment may degrade the instrument’s EMC performance. To
avoid electrical shock, do not use this instrument when volt-
ages at the measurement surface exceed 24 Vac or 60 Vdc.
To avoid damages or burns, do not perform any measure-
ment in microwave ovens.

IST98311R3    07/05

US DESIGN PATENT

D462,024

1. Battery compartment
2. Liquid Crystal Display (LCD)
3. ON/OFF/MODE button
4. 

HI 73311

 EC/TDS probe

5. Temperature sensor
6. 

SET/HOLD button

1. Automatic temperature compensation indicator
2. Stability indicator
3. Battery life percentage indicator
4. Low battery indicator
5. Secondary display
6. Primary display
7. Measuring units for primary display

SPECIFICATIONS

Range

R e s o l u t i o n

A c c u r a c y

( @ 2 0 ° C / 6 8 ° F )

Typical  EMC

Deviation

Temperature
Compensation

E n v i r o n m e n t

TDS Factor

C a l i b r a t i o n

C a l . S o l u t i o n s

HI 98311:

HI 98312:

Probe 

(

included

)

Battery Type/Life

A u t o - o f f

D i m e n s i o n s

W e i g h t

0.0 to 60.0°C / 32.0 to 140.0°F

0 to 3999 µS/cm (

HI 98311

)

0.00 to 20.00 mS/cm (

HI 98312

)

0 to 2000 ppm (

HI 98311

)

0.00 to 10.00 ppt (

HI 98312

)

0.1°C / 0.1°F

1 µS/cm ; 1 ppm (

HI 98311

)

0.01 mS/cm ; 0.01 ppt (

HI 98312

)

±0.5°C / ±1°F

±2% f.s. (EC/TDS)

±0.5°C / ±1°F

±2% f.s. (EC/TDS)

Automatic, with 

β

=0.0 to 2.4%/ºC

0 to 50°C (32 to 122°F); RH 100%

0.45 to 1.00 (CONV)

Automatic, 1 point

HI7031

 (1413 µS/cm)

HI7032

 (1382 ppm; CONV=0.5)

HI70442 

(1500 ppm; CONV=0.7)

HI7030

 (12.88 mS/cm)

HI70038

 (6.44 ppt; CONV=0.5

       or 9.02 ppt; CONV=0.7)

HI 73311

 

EC/TDS probe

4 x 1.5V with BEPS/approx. 100 hours

After 8 minutes of non-use

163 x 40 x 26 mm (6.4 x 1.6 x 1.0”)

100 g (3.5 oz.)

Hanna Instruments reserves the right to modify the design, con-
struction and appearance of its products without advance notice.

Dear Customer,
Thank you for choosing a Hanna product.
This manual will provide you with the necessary
information for a correct operation. Please read it
carefully before using the meter.
If you need additional technical information, do not
hesitate to e-mail us at 

tech@hannainst.com

.

These instruments are in compliance with the
directives.

Reviews: