Dear Customer, 

Thank you for choosing a Hanna Instruments product. Please read this instruction manual 
carefully before using the thermologger. For more information about Hanna Instruments and our 
products, visit www.hannainst.com or e-mail us at sales@hannainst.com.
For technical support, contact your local Hanna Instruments Office or e-mail us at 
tech@hannainst.com.

Preliminary Examination

Remove the thermologger from the packing material and examine it carefully. If you require any further 
information, please contact Hanna Instruments technical support team at: tech@hannainst.com. 
Each 

HI148

 is delivered in a cardboard box and is supplied with:

• USB Type A to C cable
• AAA alkaline batteries
• Wall cradle
• Quality certificate
• Instruction manual

Note: 

Ensure that the thermologger functions correctly and save all packing material. Items that need 

to be returned must be returned in their original packing material with the supplied accessories.

PC Software

The 

HI92148

 PC application software supports communication between the logger and a PC 

running Windows XP or newer. The PC application allows users to set data acquisition parameters 
and download logged data when connected to the PC. The PC software is available for download at 

http://software.hannainst.com

. After download is complete, use the setup.exe file to install the software.

General Description & Intended Use

The 

HI148

 thermologgers are designed to monitor facilities in food processing industry, transportation 

sectors, museums or horticulture. There are four models of 

HI148

 thermologgers available.

The thermologgers feature extensive memory capacity: 16,000 samples for 1-channel models and 8000 
samples/channel for 2-channel models. 

HI148 Models

HI148-1

1 internal sensor
no external sensor

SN: XXXXXXXX

HI148-1

T1 internal: -20 to 60 °C

HI148-2

no internal sensor
1 external sensor

SN: XXXXXXXX

HI148-2

T1 external: -40 to 125 °C

HI148-3

1 internal sensor
1 external sensor

SN: XXXXXXXX

HI148-3

T2 external: -40 to 125 °C

T1 internal: -20 to 60 °C

HI148-4

no internal sensor
2 external sensor

SN: XXXXXXXX

HI148-4

T1 external: -40 to 125 °C

T2 external: -40 to 125 °C

Specifications

Model

Sensor(s) 

HI148-1

T1 internal

-20.0 to 60.0 ºC / -4.0 to 140.0 ºF

HI148-2

T1 external

-40.0 to 125.0 ºC / -40.0 to 257.0 ºF

HI148-3

T1 internal
T2 external

-20.0 to 60.0 ºC / -4.0 to 140.0 ºF
-40.0 to 125.0 ºC / -40.0 to 257.0 ºF

HI148-4

T1 external
T2 external

-40.0 to 125.0 ºC / -40.0 to 257.0 ºF
-40.0 to 125.0 ºC / -40.0 to 257.0 ºF

Resolution

0.1 ºC (-40.0 to 100.0 ºC); 0.2 ºC (temp. >100.0 ºC)
0.1 ºF (-40.0 to 190.0 ºF) ; 0.3 ºF (temp. >190.0 ºF)

Accuracy

±0.5 ºC (-40.0 to 0.0 ºC and 70.0 to 100.0 ºC)
±0.4 ºC (0.0 to 70.0 ºC)
±1 ºC (>100.0 ºC)

±1 ºF (-40.0 to 32.0 ºF and 158.0 to 212.0 ºF)
±0.8 ºF (32.0 to 158.0 ºF)
±2 ºF (>212.0 ºF)

Probe

stainless steel probe with 1 m (3.3’) silicone cable;  
33.5 mm (13.2") length, 3.5 mm (0.14") diameter

Battery Type

3 x 1.5V AAA

Battery Life

approximately 2 years of use

Environment

-20.0 to 60.0 ºC (-4.0 to 140.0 ºF); RH 100%

Dimensions

107 x 59 x 17 mm (4.2 x 2.3 x 0.7“)

Weight

130 g (4.6 oz)

Note: 

HI148-4

 has the probes marked with T1 and T2.

Main Features

• One or two channels, with internal and/or external sensor
• 16,000 samples (for 1-channel models) or 8000 samples/channels (for 2-channels models)
• Programmable logging interval from 1 second to 24 hours for 1-channel models, from 2 seconds to 

24 hours for 2-channel models

• Storing of temperature at logging interval, or min. or max. temperature between logging intervals
• Logging delay start from 1 second to 199 hours using the 

HI92148

 PC application or the Log start 

button 

• Programmable high and low alarms
• Non-volatile storage of logging parameters and data in EEPROM
• BEPS (Battery Error Prevention System)
• Security password and lot serial number
• USB Type-C connector
• IP67 waterproof casing

Expected battery-life is 2 years at 1 minute measuring and logging intervals.
All 

HI148

 thermologgers are factory calibrated.

Probe Features

• The temperature sensor is located at the tip of the probe.
• The 1 m (3.3’) silicone cable maintains flexibility and performance in applications where temperatures 

are widely variable.

• The recommended immersion level is 2.5 cm (1.0”).

Display Description

Status

Temperature

Information

The LCD display features a wide temperature range and viewing angle. It displays the following 
information: status – first line at the top, readout temperature – middle line and additional information 
– bottom line.
The information shown on the bottom line is user selectable, and can include the min. and max.
temperature, the high and low alarm thresholds, the current number of samples and the number of 
samples outside alarm limits.

Functional Description

1

2

3

4

5

Temperature Logger

SN: XXXXXXXX

HI148-2

T1 external: -40 to 125 °C

1. LCD
2.  Red LED
3.  Green LED

4.  Log start button
5.  USB port cover

The status of the thermologger is indicated by the green and red LEDs, and LCD status line.

Condition

LEDs

LCD Status Line

Waiting to start logging

Green LED flashes twice every 4 seconds

WAIT TO LOG

Currently logging

Green LED flashes once every 4 seconds

LOG

Completed logging

Green LED off

LOG DONE

User alarm thresholds exceeded 
during logging

Red LED flashes once every 4 seconds

ALARM

Low battery

Red LED flashes once every 4 seconds

BATT

Dead battery

Red LED flashes twice every 4 seconds

BATT

only

Keeping the log start button pressed will light up the green LED (even outside logging session).