background image

 

 

MultiDos HighSpeed 37000 

EN

 

 

Item number: 010

-

123

-

000

 

 

Date: August 2018

 

Version 2 

-

 Translation of original instructions for use 

 

According to Annex VllA of machine directive 2006/42/EG, for completed machinery

 

 

Doetinchem, 

 

The Netherlands

 

www.hanskamp.nl/en

 

Vloeistof Doseersysteem

 

Liquid Dosing system

 

Flüssigkeit Dosiersystem

 

Liquide Systeme de dosage

 

Installation and operating instructions

 

Summary of Contents for MultiDos HighSpeed 37000

Page 1: ...original instructions for use According to Annex VllA of machine directive 2006 42 EG for completed machinery Doetinchem The Netherlands www hanskamp nl en Vloeistof Doseersysteem Liquid Dosing syste...

Page 2: ...are Hanskamp shall not be lia ble for errors or faults in this manual The recommendations are meant to serve as guidelines All instructions pictures and specifications in this manual are based on the...

Page 3: ...to very easily dose the right quantity of liquids per day and per cow Smart fast and affordable MultiDos HighSpeed doses liquid propylene glycol like gravy on top of the feed chunks And cows love it T...

Page 4: ...ance of your MultiDos High Speed You must make sure that you and anyone else who is going to operate maintain or work in the vicinity of the MultiDos HighSpeed knows all the related safety infor matio...

Page 5: ...the electrical system and all parts of the MultiDos HighSpeed meet the local rules and regulations Replace any damaged electrical lines conduits switches and components immediately Isolate the electri...

Page 6: ...HighSpeed Switch off the electrical power supply by taking plug out of the power point and secure the plug before you clean or do maintenance on the MultiDos HighSpeed Wear protective clothing and saf...

Page 7: ...t consists out of a MultiDos HighSpeed wall mount a pressure hose suction hose and a nozzle The wall mount will be send in a box These boxes can be put on each other on a pallet Please note Always use...

Page 8: ...ttom of the storage tank There are two ways to mount the MultiDos HighSpeed 3a Mount it to the wall Drill holes into the back of the MultiDos HighSpeed as illustrated in figure 3 The distance required...

Page 9: ...e 6 Mount the following items 001 453 000 001 486 000 and 011 021 000 as illustrated in figure 7 7 Use the accompanying screws art no 003 510 000 to fix the pump housing to the wall mount 8 Unscrew th...

Page 10: ...tyTube round and slide it over the hose tailpiece art no 001 021 000 on the left side 11 Attach the suction hose art no 082 254 100 max 2 metres to the right side of the insert coupling 12 Insert the...

Page 11: ...ard Maintenance Check the MultiDos HighSpeed system daily for malfunctions and wear Perform a visual inspection of the supply and discharge hoses and electrical wiring Periodically check the dispensin...

Page 12: ...s Disassembly In case of disassembly all parts should be separated on material type and should be processed in the right type of waste management system Please note When disassembling the MultiDos Hig...

Page 13: ...out of the nozzle while the motor doesn t run False air between the pump and the nozzle or nozzle is not mounted vertically Press the hose on the nozzle again check improve the sealing between the co...

Page 14: ...ation pertains does meet the stipulations of the following directive s Machine Directive 2006 42 EC and completely or partially meets the following essential requirements and that the relevant technic...

Page 15: ...mation nozzle holders 003 533 001 Drill holes to mount the hose and nozzle insert the hose through the center hole and mount the nozzle to the hose Attention Always mount the nozzle vertically 003 533...

Page 16: ...xample Art Nr 037 323 000 A MultiDos HighSpeed 200RPM 24VDC Consists of 1 pump Built in blue wall mount cover Art Nr 037 323 000 Color 1 Black 2 Green 3 Blue 4 Red 5 Orange Motor 1 DC 120RPM no longer...

Page 17: ...mulation for each application 4 The HanskampQualityTube is not intended or recommended for medical applications The use of this product in any medical application is solely the responsibility of the m...

Page 18: ...er or milking machine dealer of the apparatus the MultiDos HighSpeed regarding HanskampQualityTube installation pump rollers guide rollers and supply channel maintenance and cali bration Inspect the H...

Page 19: ...000 Shaft circlip ring for MD HS 1 082 254 100 Airtube PA12W 25m 12x10 natural 0 1 082 254 100 Airtube PA12W 25m 12x10 natural 0 4 Art no Description Num ber 003 501 000 Pump housing MultiDos HighSpe...

Page 20: ...hanskamp nl en MultiDos HighSpeed EN Doseersysteem Dosing system Dosiersystem Systeme de dosage Hanskamp AgroTech B V Broekstraat 17 7009 ZB Doetinchem The Netherlands Tel 31 0 314 393 797 Fax 31 0 3...

Reviews: