• If the user use the product with methods other than specified by the
manufacturer, there may be bodily injuries or property damages.
• If there is a possibility of an accident caused by errors or malfunctions of
this product, install external protection circuit to prevent the accident.
• Since this product does not have the power switch or a fuse, please install
those separately on the outside. (Fuse rating: 250V 0.5A)
• To prevent damage or failure of this product, please supply the rated
power voltage.
• To prevent electric shock or equipment failure, please do not turn on the
power until completing wiring.
• Since this is not explosion-proof structure, please do not use in a place
where combustible or explosive gas is around.
• Never disassemble, modify, or repair the product. There is a possibility of a
malfunction, an electric shock, or a risk of fire.
• Please turn off the power when mounting/dismounting of the product. This
is a cause of an electric shock, a malfunction, or failure.
• Since there is a possibility of an electric shock, please use the product as
mounted on a panel while the power is being supplied.
• The contents of the instruction manual are subjective to change without
prior notice.
• Please make sure that the specification is the same as what you have
ordered.
• Please make sure that the product is not damaged during shipping.
• Please use this product in a place where corrosive gas (such as harmful
gas, ammonia, etc.) and flammable gas do not occur.
• Please use this product in a place where there is no direct vibration and a
large physical impact to the product.
• Please use this product in a place where there is no water, oil, chemicals,
steam, dust, salt, iron or others (Contamination class 1 or 2).
• Please do not wipe this product with organic solvents such as alcohol,
benzene and others. (Please use mild detergent)
• Please avoid places where excessive amounts of inductive interference
and electrostatic and magnetic noise occur.
• Please avoid places where heat accumulation occurs due to direct sunlight
or radiant heat.
• Please use this product in a place where the elevation is below 2,000 m.
• Please make sure to inspect the product if exposed to water since there is
a possibility of an electric leakage or a risk of fire.
• If there is a lot of noise from the power line, installing an insulated
transformer or a noise filter is recommended. The noise filter should be
grounded on the panel and the lead wire between the output of the noise
filter and the power terminal of the instrument should be as short as
possible.
• It is effective against noise if making the power lines of the product the
twisted pair wiring.
• Please do not connect anything to the unused terminals.
• Please connect wires properly after making sure the polarity of terminal.
• Please use a switch or breaker (IEC60947-1 or IEC60947-3 approved)
when the product is mounted on a panel.
• Please install a switch or break near the operator to facilitate its operation.
• In order to use this product properly and safely, we recommend periodic
maintenance.
• Some parts of this product have limited expected life span and aged
deterioration.
CAUTION
Model
Code
Description
GE
☐
-
☐
☐
☐
☐
Digital counter & timer
Appearance
3
96(W) × 48(H)
㎜
4
48(W) × 48(H)
㎜
6
72(W) × 36(H)
㎜
7
72(W) × 72(H)
㎜
Type
P
Preset counter
T
Total counter (Only for indication)
Displayable digit
4
4 digits (9999)
*
GE3 and GE7 are not selectable
6
6 digits (999999)
Setting stage
(excludes the total counter)
1
1 Stage setting
2
2 Stage setting
Power supply voltage
A 100 - 240 V a.c 50 - 60
㎐
D
24 - 60 V d.c / a.c 50 - 60
㎐
※ If you want to input and output type, please contact HANYOUNG sales office
Digital counter & timer
GE series
Thank you for purchasing HANYOUNG product.
Please check whether the product is the exactly same as you ordered.
Before using the product, please read this instruction manual carefully.
Please keep this manual where you can view at any time
INSTRUCTION MANUAL
1381-3, Juan-Dong, Nam-Gu Incheon, Korea.
TEL:(82-32)876-4697 FAX:(82-32)876-4696 http://www.hynux.net
JL.CEMPAKA BLOK F 16 NO.02 DELTA SILICON II INDUSTRIAL PARK
LIPPO CIKARANG CICAU, CIKARANG PUSAT BEKASI 17550 INDONESIA
TEL : 62-21-8911-8120~4 FAX : 62-21-8911-8126
HEAD OFFICE
INDONESIA
FACTORY
HANYOUNGNUX CO.,LTD
PT. HANYOUNG ELECTRONIC INDONESIA
Do not touch or contact the input/output terminals because it may cause
electric shock.
DANGER
WARNING
• The warranty of this product (including accessories) is 1 year only when it
is used for the purpose it was intended under normal condition.
• When the power is being supplied there should be a preparation time for
the contact output. Please use a delay relay together when it is used as a
signal on the outside of interlock circuit or others.
Suffix code
Specification
Model
GE4
GE6
GE3
GE7
Power supply voltage 100 - 240 V a.c 50 - 60
㎐
, 24 - 60 V d.c/a.c (voltage fiuctuation : ±10
%
)
Power consumption
Approx. 13.5 VA(100 - 240 V a.c), approx. 5 W(24 - 60 V d.c),
Approx. 9 VA(24 - 60 V a.c)
Charater height(
㎜
)
11 (computed), 8 (set value)
13 (computed), 10 (set value)
Input counting
speed
1 cps, 30 cps, 1 kcps, 10 kcps
(ON/OFF ratio : 1:1, "H" level : 5 - 3 V d.c, "L" level : 0 - 2 V d.c)
Memory back-up
10 years (non-volatile memory)
Input
CP1, CP2, RESET, BATCH RESET (exclude TOTAL) 4inputs
[H] level 4 - 30 V d.c, [L] level 0 - 2 V d.c Internal pull up/pull down
resistance connection due to NPN/PNP setup
Min input
signal
Counter External reset Min. input signal range : select among 0.1
㎳
, 1
㎳
, 20
㎳
Timer START, INHIBIT, RESET Min. input signal range : select either 1
㎳
, 20
㎳
External supplying power
12 V d.c 100
㎃
max
ONE SHOT output
0.01 - 99.99 s [OUT1, OUT2(OUT)]
Control
output
1
st
level
1c (OUT)
1a (OUT)
1c (OUT)
2
st
level
1a (OUT1), 1c (OUT2)
capacity a contact : 250 V a.c 3 A (resistive load), b contact : 250 V a.c 2 A
1
st
level
NPN 2contacts (OUT, BAT.O)
2
st
level
-
-
NPN 2 contact (OUT1, OUT2)
capacity
Open collector, 30 V d.c, 100
㎃
max
Timer action error
With power start : ±0.01 % ±0.05 sec max
With reset start : ±0.005 % ±0.003 sec max
Insulation
resistance
100
㏁
min (500 V d.c) Between current-carrying terminals and exposed
non-current -carrying metal parts.
Dielectric strenght 2000 V a.c 60 Hz for 1 min (diferrerent recharging terminal from each other)
Noise resistance
Square wave by the nois simulator (1
㎲
pulse per 16
㎳
)
±2
㎸
(Power supply terminal), ±500 V (Input terminal)
Vibration resistance 10 - 55
㎐
, peak amplitude 0.5
㎜
, 3 axis each direction for 2 hour
Shock resistance
300
㎨
, 3 axis each three times
Relay life
Electrical
100 thousand times min (250 V a.c 2 A resistance load)
Mechanical
1 million times min
Protection structure
IP65 (Front part only)
Storage temperature
-20 ℃ ~ 65 ℃
Ambient temperature
humidity
-10 ℃ ~ 55 ℃, 35
%
~ 85
%
RH
Weight
133 g max
138 g max
203 g max
203 g max
Contact
Non-contact
Safety information
DANGER indicates an imminently hazardous situation
which, if not avoided, will result in death or serious injury
WARNING indicates a potentially hazardous situation
which, if not avoided, could result in death or serious injury
CAUTION indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury
Before using the product, please read the safety information thoroughly and use it properly.
Alerts declared in the manual are classified to Danger, Warning and Caution by their criticality.
DANGER
WARNING
CAUTION