background image

INSTRUCTION MANUAL

MASSIO CONTROLPADS AND KEYPADS

MCP-106, MCP-108, MKP-106, MKP-108

Summary of Contents for AMX MCP-106

Page 1: ...INSTRUCTION MANUAL MASSIO CONTROLPADS AND KEYPADS MCP 106 MCP 108 MKP 106 MKP 108...

Page 2: ...pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 ONLY USE attachments accessories specified by the manufacturer 12 USE ONLY with a cart stand...

Page 3: ...is connected Consult the dealer or an experienced radio TV technician for help Approved under the verification provision of FCC Part 15 as a Class B Digital Device Caution Changes or modifications no...

Page 4: ...Serial 14 LAN RJ 45 15 Applying Power 15 ID Pushbutton 16 Installation 18 Overview 18 Mounting Procedures 18 Wallbox Mounting 18 Button Labeling 20 Overview 20 Installing Acetate Button Labels 20 Dis...

Page 5: ...ing Massio ControlPad Firmware Files on www amx com 29 Required Order of Firmware Updates 29 Upgrading Firmware via NetLinx Studio 30 Resetting the Factory Default System and Device Values 32 Programm...

Page 6: ...name 39 GET IP 39 GET LOCATION 39 GET SN 39 INFO 39 MSG ON OFF 39 NDP UNBIND 39 PING ADDRESS 39 REBOOT 39 RENEW DHCP 40 RESET FACTORY 40 SET CONNECTION 40 SET DEVICE 40 SET DNS 40 SET ETHERNET MODE 40...

Page 7: ...nd maintenance Display Monitoring Use the ControlPad with RMS to monitor power status input status lamp hours and filter hours Web based Control Remotely login to ControlPads and execute button presse...

Page 8: ...wer Draw 4 5W Power Supply External Required Any POE injector or switch conforming to the 802 3af standard including AMX s PS POE AF TC FG423 83 not included Environmental Temperature Operating 32 F t...

Page 9: ...rature Storage 14 F to 140 F 10 C to 60 C Humidity Operating 5 to 85 RH Ethernet Ethernet Connection 1 10 100 Port provides TCP IP communication This is an Auto MDI MDI X enabled port which allows you...

Page 10: ...ait 4 11 16 x 3 7 16 x 9 16 119 mm x 87 5 mm x 13 9 mm Landscape 3 7 16 x 4 11 16 x 9 16 87 5 mm x 119 mm x 13 9 mm Mount onto standard 1 gang US UK or EU back boxes Weight Approximately 0 25 lb 0 11...

Page 11: ...h Indicator ID Pushbutton Reset factory settings reset factory image toggle between DHCP or static IP addressing mode Colors Available Black MKP 108L BL FG5793 08L BL White MKP 108L WH FG5793 08L W Ac...

Page 12: ...e on each type of Massio ControlPad Here you can find wiring and electrical capacities for each type of connector FIG 3 displays the rear panel of the MCP 106 FIG 3 MCP 106 rear panel FIG 4 displays t...

Page 13: ...EIA 232 F signal levels The RX line supports polling for RS 232 devices for statuses such as power status input status and lamp hours so that this information can be provided to RMS NOTE Massio Contr...

Page 14: ...gic but can handle up to 12V without harm The following table provides wiring requirements for the I O port IR Serial You can connect up to two IR controllable devices to the IR connectors to the Mass...

Page 15: ...G 10 LAN port FIG 11 provides the pinouts and signals for the LAN connector and cable FIG 11 RJ 45 wiring diagram NOTE If Ethernet connectivity is lost on any ControlPad and then re established connec...

Page 16: ...device is restored to the factory default so you will lose any scripts IRL files Device Interrogation settings or RMS server information loaded on the system Restore the factory image on the ControlP...

Page 17: ...dscape You can also simultaneously press buttons 4 5 and 6 to power cycle the device Press all three buttons simultaneously and hold them for 20 seconds to power cycle the device see FIG 16 FIG 16 Pre...

Page 18: ...ox Mounting Perform these steps to mount the device into a back box 1 Install the back box into the surface of the desired location for the device Be sure to thread any appropriate wiring through the...

Page 19: ...of the metal clip on the 6 button devices FIG 20 Metal clip from mounting bracket locking device frame onto bracket FIG 21 displays the locations of the metal clips on the 8 button devices FIG 21 Met...

Page 20: ...l the acetate button labels and Button Caps 1 Remove the faceplate from the device 2 Remove the cone and diffuser from the button The cone and diffuser are adhered together and should not be separated...

Page 21: ...teps This procedure requires a flat head screwdriver 1 Use the flat head screwdriver to locate the two small ridges at the bottom of the faceplate and gently pry the faceplate away from the device fra...

Page 22: ...into place 4 Press the bottom corners of the device frame to snap them into place The metal clips on the mounting bracket should align with the open spaces located at the bottom of the device frame Th...

Page 23: ...preferable application Before You Start 1 Verify you have the latest version of the NetLinx Studio application version 4 0 installed on your PC NetLinx Studio is available to download from www amx com...

Page 24: ...ield to view edit the ControlPad s current Host Name NOTE Host names may contain only the ASCII letters a through z in a case insensitive manner the digits 0 through 9 and the hyphen Use DHCP Specify...

Page 25: ...the ControlPad has an unknown static IP address you can obtain the IP address of the controller via USB 1 Using a standard Micro USB cable connect the Program Port on the rear panel of the ControlPad...

Page 26: ...trolPad to simulate the functions of the ID pushbutton You must keep both buttons pressed for 10 seconds as you would with the ID pushbutton to toggle between IP address modes See the ID Pushbutton se...

Page 27: ...tem click the down arrow to select which device you want to bind 5 Select the check box next to the Master to which you want to bind the keypad If there is more than one Master in the system check the...

Page 28: ...oaded on the controller see Verifying the Current Firmware Version below Verifying the Current Firmware Version Use the OnLine Tree in NetLinx Studio see FIG 34 on page 28 to verify which version of e...

Page 29: ...etLinx Studio as you would with a typical firmware upgrade Upgrading firmware via HTTP server is typically much faster than upgrading with the standard firmware kit files See the Upgrading Firmware vi...

Page 30: ...enu Doing so establishes a new connection to the System and populates the device tree with devices on that system 3 After the Communication Verification dialog indicates active communication between t...

Page 31: ...finished rebooting 9 In the OnLine Tree right click on the Master and select Refresh System This establishes a new connection and refreshes the device list and their firmware versions in your system...

Page 32: ...the new information 3 Click Done to close the Device Addressing dialog 4 Click Reboot from the Tools Reboot the Master Controller dialog and wait for the System Master to reboot NOTE The STATUS and O...

Page 33: ...each of the Massio ControlPads MCP 106 and MCP 108 and Keypads MKP 106 and MKP 108 Channels Channels on Massio ControlPads and Keypads correspond to the button numbers on each keypad as indicated in...

Page 34: ...rovides level events on Level 2 Navigation Wheel Level Control In addition to generating button events a rotation of the knob causes a level change on Level 2 Clockwise rotations increase the level Co...

Page 35: ...bar mode 2 special bar mode A level of 1 32 turns on the first LED Each successive LED that lights represents an increment of 32 steps NOTE Modes 0 and 2 operate identically Mode 2 is available for ba...

Page 36: ...re required Enter username Enter protected password Welcome to MKP 108 v1 0 44 Copyright AMX LLC SEND_COMMANDs Cont Command Description LED EN Enable LEDs on the keypad LEDs are enabled by default Syn...

Page 37: ...n present the password prompt Here the defined password must be entered in order to successfully open the Telnet session Additional Notes Both the Telnet user name and password are case sensitive Thre...

Page 38: ...Supported data types UByte UInt EXIT Exit the telnet session FACTORYFWIMAGE Reset unit to factory firmware image and reboots the Module GET CONFIG Display the current connection settings Example get...

Page 39: ...t by the SET LOCATION command on page 41 GET SN Returns the device s serial number INFO Provides at a glance information about the keypad including any expansion keypads that are attached to it MSG ON...

Page 40: ...igned device number from the Master If the new device number is different from the old device number the Module will disconnect from the Master and begin trying to connect with the new settings NOTE T...

Page 41: ...2 Is this correct Type Y or N and Enter y Settings written Device must be rebooted to enable new settings NOTE Metreau keypads can also be set to Static IP or DHCP Mode by using the ID Pushbutton See...

Page 42: ...er a carriage return If an ALT 255 is entered two 255 characters are sent per the Telnet RAFT If the code to go back to command mode is entered ALT 29 which is the character is not sent but Telnet com...

Page 43: ...ot assume responsibility for errors or omissions AMX also reserves the right to alter specifications without prior notice at any time The AMX Warranty and Return Policy and related documents can be vi...