background image

Harman Oakwood Cast Iron Wood Stove

EPA Certified by 

OMNI-Test Laboratories

Save tHeSe InStruCtIOnS.

Installation & Operating Manual

r11

“Ce manuel est disponible en Français sur demande”

SaFetY nOtICe

PleaSe read tHIS entIre Manual beFOre YOu InStall and uSe YOur neW rOOM Heater.  FaIlure 
tO FOllOW InStruCtIOnS MaY reSult In PrOPertY daMage, bOdIlY InjurY, Or even deatH.

FOr uSe In tHe u.S. and Canada.  tHe OakWOOd IS nOt aPPrOved FOr MObIle HOMe InStallatIOn.

IF tHIS HarMan StOve IS nOt PrOPerlY InStalled, a HOuSe FIre MaY reSult.  FOr YOur SaFetY, FOllOW 
InStallatIOn dIreCtIOnS.  

COntaCt lOCal buIldIng Or FIre OFFICIalS abOut reStrICtIOnS and InStallatIOn InSPeCtIOn 
reQuIreMentS In YOur area.

COntaCt YOur lOCal autHOrItY (SuCH aS MunICIPal buIldIng dePartMent, FIre dePartMent, FIre 
PreventIOn bureau, etC.) tO deterMIne tHe need FOr a PerMIt.

Cette guIde d'utIlISatIOn eSt dISPOnIble en FranCaIS. CHez vOtre COnCeSSIOnnaIre de HarMan 
HOMe HeatIng.

#3-90-08327

Summary of Contents for R11

Page 1: ...E IN THE U S AND CANADA The Oakwood is not approved for mobile home installation IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS C...

Page 2: ......

Page 3: ...tions may result in property damage bodily injury or even death Harman Home Heating 352 Mountain House Road Halifax PA 17032 U S A INDEX INDEX Introduction 4 Specifications 5 Operation Building a Fire...

Page 4: ...catalytic stoves Top loading makes adding wood easier and allows you to view your beautiful fire through the extra large glass door The glass stays cleaner because of specially coated glass and the e...

Page 5: ...n limits for wood heaters sold after July 1 1990 Weight 440 lbs Flue Size 6 inch Log Length Recommended 21 Max Heating Capacity 2 000 sq ft Average Emissions 2 32 Grams Per Hr Emissions on Low 0 8 Gra...

Page 6: ...Harman Oakwood Andirons Grate Top Load Opening Air Control Front Load Door Top Load Door Bypass Damper Control Handle Ash Door Ash Door Latch Front Load Door Latch SPECIFICATIONS Optional Cooking Gril...

Page 7: ...y passing a poker back and forth across the grate The andirons keep the fuel from coming into direct con tact with the glass and keep hot coals and embers from spilling out while reloading Never build...

Page 8: ...ges The initial or evaporation stage is where the moisture in the wood is driven off in the form of steam A second stage is where the volatile gases contained in the wood are released and burned This...

Page 9: ...etting all the way to the right Be sure the ash pan door is closed and latched Start with a bed of crumpled paper and kindling sized about finger width place several 1 2 25mm 50mm splitpiecesofdrywood...

Page 10: ...bypass before taking the ashes outside for safe disposal Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a noncombustible floor o...

Page 11: ...pproved by either the CAN CSA B365 standard Canada or NFPA 211 U S Contact your building authority for information if you are interested in reducing clearance distances other than those presented here...

Page 12: ...12 Harman Oakwood INSTALLATION CLEARANCES See NFPA 211 for more installation clearance reductions when using USM wall protection etc 21 25...

Page 13: ...Harman Oakwood 13 INSTALLATION CLEARANCES See NFPA 211 for more installation clearance reductions when using USM wall protection etc...

Page 14: ...14 Harman Oakwood installation clearances See NFPA 211 for more installation clearance reductions when using USM wall protection etc...

Page 15: ...rth weight limitations The Oakwood should not be installed into a factory built fireplace unless the hearth area is designed to take the maximum weight of the stove The Oakwood loaded with wood weighs...

Page 16: ...loset or other concealed space or through a floor or ceiling Whenever possible avoid passing the connector through a combustible wall if you must use an approved wall pass through described later in t...

Page 17: ...200 mm may be used For square or rectangular masonry chimneys nominal sizes of 8 x 8 or 8 x 12 200 mm x 200 mm 200 mm x 300 mm may be used Codes require that solid fuel chimneys extend 3 ft 0 9 m abo...

Page 18: ...e of the chimney liner and both must be firmly cemented in place with refractory cement Athimble is a masonry pipe which is inserted through the chimney wall and is frequently the preferred method a b...

Page 19: ...id fuels are burned completely they pro duce water and carbon dioxide However in long slow burns a substantial amount of carbon monoxide may be produced If allowed to build up carbon monoxide which is...

Page 20: ...Chimney Support Standard Ceiling Installation with Factory Built Chimney Chimney Cap Factory Built Metal Chimney Sealed Storm Collar Finishing Col lar Chimney Connector Cathedral Ceiling Installation...

Page 21: ...Space Three Sheet Metal Screws per Joint of Chimney Connector Mantel and Trim Pro tection Floor Protection in Accordance with Solid Fuel Appliance Listing Airtight insulated Clean out Chimney Breach F...

Page 22: ...Extend to Flue Liner Minimum 8 Masonry Thickness in Front of Smoke Chamber Use Damper Adapter or Seal with Non Combustible Material Floor Protection in Accordance with Solid Fuel Appliance Listing Ai...

Page 23: ...ace Trim Protection for Reduced Clearance UL1777 Stainless Steel Liner System or Other approved lining system Follow liner manufacturer s instructions on insulation and support Floor Protection in Acc...

Page 24: ...Clearance for Complex ity Exterior Chimney or 2 Clearance for Interior Chimney and 2 Clear ance for NFPA 211 Type Approved Thimbles Floor Protection in Accordance with Solid Fuel Appliance Listing Ch...

Page 25: ...work the controls back and forth several times during the summer or any prolonged period when you are not using your stove The Fire Chamber The inside of the fire chamber should be examined for damag...

Page 26: ...check these gaskets from time to time and replace them when necessary The gaskets are made of fiberglass of different sizes obtainable from your Harman dealer and some are fixed in place with a high...

Page 27: ...n the smoke deflec tor may not be needed on the top vent models The Cozy Screen can be used from the start of a fire or can be used with an existing one When starting a fire with the Cozy Screen smoke...

Page 28: ...ck 1 90 02490 2 Charcoal 1 90 02490 3 goldenfire 1 90 02490 4 Metallic blue 1 90 02490 5 Honey glo 1 90 02490 10 Mojave red 1 90 02490 12 Forest green 1 2 3 4 6 8 9 10 15 16 17 18 21 22 23 24 25 26 27...

Page 29: ...Top 4 00 249105P 11 Top Load Door 3 00 249115P 12 Top Load Handle 2 00 249148 13 Left Side Panel 4 00 249103D 14 Inner Front 4 00 249111S 15 Andiron Qty 2 Req 3 00 249101P Y 16 Front Load Door 4 00 24...

Page 30: ...31 2 Inlet Brick Right 3 40 00104 Y 31 3 Logo Brick 3 40 00101 Y 31 4 Inlet Brick Left 3 40 00103 Y 31 5 Upper Brick Clip Pkg of 2 1 00 249172 Y 31 6 Rear Brick Clip Pkg of 2 1 00 249153 Y 31 7 Cast L...

Page 31: ...2494 32 4 Bottom Heat Shield Kit 1 00 02491 Hardware Packages Bolt 5 16 18 x 2 Zinc Plated Carriage Pkg of 25 3 30 4001 25 Y Bushing 3 8 OD X 1 4 OAL Pkg of 5 3 50 00058 5 Y Nut 1 4 20 Zinc Plated Fin...

Page 32: ...32 Harman Oakwood...

Page 33: ...Harman Oakwood 33...

Page 34: ...34 Harman Oakwood notes...

Page 35: ......

Page 36: ...Proudly Printed On 100 Recycled Paper...