FUSION BATT

CODE  YXC1

Circuit version 

“SB39”

Flush when moving away

ELECTRONIC FLUSHING SYSTEM 

FOR URINAL POD

ALKALINE BATTERIES (3X1,5V) OPERATED

FUSION BATT 

VT 04/10

Rev. 2

A

ENG

CLEANING RULES

5

The  urinal  pod  sensor’s  boady  is  in  STAINLESS  STEEL  AISI  316
therefore  very  resisitant  to  corrosive  products.  However  it  is
recommended,  for  cleaning  the  urinal  pod  to  use  warm  water
and  do  not  use  abrasive  detergents.  To  avoid  damaging  the
sensors  do  not  use  corrosive  products  or  metallic,  abrasive
sponges.
OTHERWISE THE WARRANTY WILL BE INVALID !

FIG. 8

• BEFORE USING THE PRODUCT READ CAREFULLY THE INSTALLATION INSTRUCTION AS WELL AS

THE ENCLOSED DRILLING DIAGRAM FOR MOUNTING THE CERAMIC URINAL POD TO THE WALL.

• HATRIA DECLINES ALL LIABILITY FOR DAMAGE OR INJURY CAUSED BY THE FAILURE TO FOLLOW ALL

THE INSTRUCTIONS PROVIDED IN THIS INSTRUCTION BOOKLET.

• THE PRODUCT'S OVERALL RELIABILITY AND DURATION ARE ENSURED BY CORRECTLY PERFORMING

ALL THE OPERATIONS PROVIDED IN THIS BOOKLET. 

• KEEP THIS BOOKLET IN A SAFE PLACE.

• THIS PRODUCT MUST BE INSTALLED BY PROFESSIONALLY QUALIFIED PERSONNEL.

• THE PLUMBING SYSTEMS CONNECTED TO THE EQUIPMENT MUST COMPLY WITH THE STANDARDS

IN FORCE.

!

!

INSTRUCTIONS FOR CHECKING AND REPLACING BATTERIES

4

CHECK

The  electronic  flushing  system 

FUSION  BATT

is  fed  by  3  low-cost  and  readily  available

batteries • The batteries used are of alkaline type of 1.5 V-Size AA • The operation voltage is 4,5
Vdc (3 x 1.5V). • The batteries durability is approx. 4 years for 200 operations per day • 

Do not

use rechargeable batteries

• Purchase 

only

batteries that have a stamped expiry date which is

a minimum of 4 years after the date of your purchase. This will ensure a long durability of batteries
and  a  correct  use  of  your  electronic  flushing  system 

FUSION BATT

.  •  Do  not  replace  the

batteries with wet or damp hands, in damp places or with damp tools. • 

Water must never be

inside the battery pack

otherwise batteries will be immediately discharged!

REPLACEMENT

When the red LED (2) (Fig. 2) starts to flash at regular intervals of 2 sec., it means that batteries
are being used up. However they will keep a residual period of operation which varies according
to the number of operations. To replace the batteries effect the following operations :
A) Disconnect (16) the battery pack and the circuit.
B) Remove the cover (19) of the battery pack by unscrewing 4 screws (20). Take the batteries out.
C) Insert the new batteries in the battery pack by paying attention to the  polarity 

+

and 

-

.

D) Remount the cover of the battery pack paying attention at the gasket (21) in its seat.
E) At this point it may be reset the connection (16) between the battery pack and the circuit.

19

20

21

16

FIG. 7

OUT

ø

4

0

4

0

5

3

6

0

6

5

0

305

325

4

0

5

6

8

5

1

0

°

G

1

/2

MAX

FISSAGGI

IN

5

3

80

OVERALL DIMENSIONS

mm

fasteners

FIG. 9

IT IS RECOMMENDED TO EFFECT THE DISPOSAL OF THE USED UP BATTERIES ACCORDING TO THE NORMS IN FORCE

!

INSTALLATION AND MAINTENANCE

INSTRUCTIONS AND DRILLING DIAGRAM FOR

MOUNTING THE URINAL POD TO WALL

C

o

d

0

9

3

5

.E

N

G

Hatria S.p.A 

tel. +39 059 384556 • fax +39 059 384212 
venditeitalia@hatria.com •
exportdpt@hatria.com • www.hatria.com 

Reviews: