background image

 

01/21   1210 Series Bottle Fillers 

    

 Page 1 of 17   

 

 

1455 Kleppe Lane 

Sparks, NV 89431-6467 

(775) 359-4712 

Fax (775) 359-7424 

E-mail

haws@hawsco.com

 

 

website

www.hawsco.com

 

 

 

 

 

 

 

 

 

 

 

 

No. 0510001059 (1) 

 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 

Bottle Filling Stations 

MODELS 1210S AND 1210SF 

 

 

 

INSTALLATION, OPERATION 

MAINTENANCE INSTRUCTIONS 

SAFETY PRECAUTIONS 

 

CAUTION:  Disconnect electrical power to outlet before installing or servicing. 
 
NOTICE:   

A.  The electrical receptacle must have code-approved ground-fault circuit 

interrupter (GFCI) protection for personnel. 

B.  Care should be taken not to damage refrigeration system lines or 

electrical wires during installation. 

C.  Installation must conform to all applicable codes and standards. 
D.  Maintain 8 inches (20cm) separation from filter circuit board (antenna) at 

all times. 

 
 

 

NOTE TO INSTALLER: Please leave this information with the Maintenance Department.

 

 

FULL-SCALE ROUGH-IN TEMPLATE (PN 0510001160) AVAILABLE UPON REQUEST. 

SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS 
MODEL PLEASE CALL: 
 

      TECHNICAL SUPPORT: 

1-800-766-5612 

 

FOR CUSTOMER SERVICE: 

1-888-640-4297 

Summary of Contents for 1210S

Page 1: ...approved ground fault circuit interrupter GFCI protection for personnel B Care should be taken not to damage refrigeration system lines or electrical wires during installation C Installation must conform to all applicable codes and standards D Maintain 8 inches 20cm separation from filter circuit board antenna at all times NOTE TO INSTALLER Please leave this information with the Maintenance Depart...

Page 2: ...se only These units are unsuitable for corrosive environments such as enclosed chlorinated pool areas or very dusty areas The ambient air temperature must be maintained between 40 F and 94 F at all times Installation into a location not meeting these limitations will void the warranty SUPPLY LINE The minimum recommended size is 1 2 IPS with 30 90 psig 2 6 ATM flowing pressure Where sediment or min...

Page 3: ... 360 degrees turn with a wrench using the line to count turns 8 Install the P trap If necessary trim the drain tailpiece in place so it interfaces properly with the P trap inlet Pliers may be required to tighten the nuts to a leak tight condition 9 If the unit has a filter install the filter now Take care not to damage the circuit board which is near the filter head 10 Note that the thermostat is ...

Page 4: ...o touch the plastic parts or the bottle filler D OPTIONAL PROGRAMMING INSTRUCTIONS To enter programming mode remove the skirt and use a nonmetallic object such as the back end of a plastic pen to hold the blue button until the up down arrow keys and select appear on the bottle filler display Programming mode enters at the top level menu In general the up down arrows and select keys work as follows...

Page 5: ... menu Cancel returns to main menu without changing program Sets 12 hour clock AM or PM and advanced to programming OFF time see Note 1 Cancel returns to main menu with changing program Off 1 to 12 sets hour to turn Off energy saving and advance to A or P field see Note 1 Cancel returns to main menu without changing program Sets 12 hour clock AM or PM and advanced to OFF setting see Note 1 Cancel r...

Page 6: ... damage the circuit board located near the filter head during the following steps 1 Remove the 4 screws holding the skirt to the bottom of the frame Then remove the skirt by sliding the skirt away from the lower unit 2 Place a towel or bucket below the lower unit to collect the small amount of water that may drip from the filter head or filter during the next steps 3 Optional Turn the water supply...

Page 7: ...INDICATION LIGHTS VISIBLE AFTER REMOVING THE SKIRT Power Red LED o Solid ON when power is applied Filter Blue LED Filtered units only o Solid ON Filter life 100 to 11 remaining o Intermittent Flash once 3 second Filter life 10 to 0 remaining o Rapid Flash once second Filter life expired Energy Saving Green LED o OFF Energy Saving Mode disabled o Solid ON Energy Saving Mode enabled o Rapid Flash on...

Page 8: ...lenoid valve is working 2 Low water flow from bottle filler a b c d e Replace filter Verify minimum 30 psig supply pressure Verify supply valve is in full open position Unscrew aerator and flush with clean water Replace aerator 3 Water leaking a Shut off water supply and contact Haws Technical Support 1 800 766 5612 4 Water from bottle filler nozzle excessively splatters when contacting drain basi...

Page 9: ...t and ensure fan runs initially for approximately 10 seconds Clean condenser fins of dust and debris Verify inlet water and ambient temperatures are below specification maximum 2 E012 SENOB Bottle filler sensor is obstructed a b c Clear error in programming mode and power cycle unit and check error to validate Remove obstruction from aperture Clean aperture with soft cloth that won t scratch apert...

Page 10: ...Compliance Statement This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation I 2 2 Declaration de Conformité Le présent appareil est conforme aux CNR d Industrie Canada applicables aux ...

Page 11: ...ory repair department but only if the part or parts and the purported defect or defects are covered by this Limited Warranty in Haws sole discretion When the product is located outside the United States and Canada Haws obligation under this Limited Warranty includes only providing a replacement for any part expressly covered by this Limited Warranty which is found to be defective by Haws or its ag...

Page 12: ...0410000746 0410000746 26 DRAIN GRATE 0410000748 0410000748 27 PLATFORM SUPPORT 0410000747 0410000747 28 PLATFORM 0410000749 0410000749 THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE APPROVED DRAWN PART NUMBER SCALE REVISION 0A 0 1 8 DRAWING TYPE SIZE A 5647 BY PARTS BREAKDOWN DATE DATE RE...

Page 13: ... 17 PAGE 13 OF 17 NOTES 1 HOLD PLUMBING ELECTRICAL DIMENSIONS 1 4 6 4mm HOLD MOUNTING DIMENSIONS 1 8 3 2MM 2 ADHERING TO PROVIDED INSTALLATION HEIGHT DIMENSIONS WILL ALLOW THE BOTTLE FILLER TO BE INSTALLED AT ADULT ADA HEIGHT IN MOST CASES DIMENSIONS MARKED CAN BE INCREASED BY UP TO 4 IN EQUIVALENT AMOUNTS WHEN INSTALLING THIS UNIT LOCAL STATE OR FEDERAL CODES SHOULD BE ADHERED TO TYPICAL INSTALLA...

Page 14: ...2021 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE APPROVED DRAWN PART NUMBER SCALE REVISION JL 07 25 18 0A 0 1 12 DRAWING TYPE SIZE A 5647 BY INSTALLATIO...

Page 15: ...8mm OR BETWEEN 6 152mm 8 3 4 229mm BELOW THE LOWERMOST EWC MOUNTING BRACKET HOLES IN ORDER FOR THE P TRAP TO AFFIX PROPERLY TO THE DRAIN TAILPIECE DEPENDING ON STUB OUT HEIGHT SOME TRIMMING OF THE TAILPIECE WILL BE REQUIRED 6 WHATEVER P TRAP AND STUB OUT PLUMBING ARE USED CARE SHOULD BE TAKEN TO ENSURE THAT THE P TRAP CAN SEAL TO THE STUB OUT PROPERLY AND STILL ALIGN TO THE DRAIN TAILPIECE LOCATED...

Page 16: ...LE DEPENDING ON VALVE LOCATION WATER SUPPLY VALVE IS PERMISSIBLE IN THIS AREA FOR UNFILTERED UNITS ONLY VALVE MAY PROTRUDE 2 3 4 MAXIMUM FROM WALL LARGE ESCUTCHEONS MAY NOT BE FEASIBLE DEPENDING ON VALVE LOCATION PAGE 16 OF 17 RETROFIT INSTALLATION DETAILS PAGE 16 OF 17 2021 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Co...

Page 17: ...d HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE APPROVED DRAWN PART NUMBER SCALE REVISION JL 07 25 18 0A 0 1 8 DRAWING TYPE SIZE A 5647 BY INSTALLATION DATE DATE REV ECN 5647 CHK D MODEL S 14...