background image

 

 

01/10 

Model 2000SM 

Page 1 of 9 

 

 

 

 

 

                     

1455 Kleppe Lane  Sparks, NV 89431-6467  (775) 359-4712  Fax (775) 359-7424 

E-mail: 

haws@hawsco.com

 

 

website: 

www.hawsco.com

 

 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

Model 2000SM 

HydrationStation

TM

 

INSTALLATION, OPERATION 

MAINTENANCE INSTRUCTIONS

No. 2080108 (2) 

LIMITED WARRANTY

 

 

HAWS

®

 warrants that all of its products are guaranteed against defective material or poor 

workmanship for a period of 

one year from date of shipment.

 HAWS liability under this 

warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any 
goods, or part thereof, which shall appear to the Company upon inspection to be of 
defective material or not of first class workmanship, provided that claim is made in writing 
to company within a reasonable period after receipt of the product. Where claims for 
defects are made, the defective part or parts shall be delivered to the Company, prepaid, 
for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, 
or for any expense connected therewith made by the owner or his agents, except upon 
written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages 
caused by defective materials or poor workmanship, except for replacements, as provided 
above. Buyer agrees that Haws has made no other warranties either expressed or implied 
in addition to those above stated, except that of title with respect to any of the products or 
equipment sold hereunder and that HAWS shall not be liable for general, special, or 
consequential damages claimed to arise under the contract of sale. The drinking fountain 
manufactured by HAWS is warranted to function if installation and maintenance 
instructions provided are adhered to. The units also must be used for the purpose for 
which they were intended.  

NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED 
OR GIVEN BY HAWS. 

NOTE TO INSTALLER: Please leave this information with the Maintenance Department. 

A ground-fault circuit breaker shall be installed 
in the branch circuit supplying fountain 
equipment. NEC680-51(a). 

 

CAUTION!

 Prior to making any electrical 

connections, verify with a voltmeter that power 
from the service panel is 

off.

 

SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS 
MODEL, PLEASE CALL:  

1-800-766-5612 

FOR PARTS CALL: 

 

1-800-758-9378  

 

 (U.S.A. AND CANADA ONLY) MONDAY-THURSDAY: 6:00 A.M. – 4:00 P.M. PST 

FRIDAY: 6:00 A.M – 1:00 P.M. PST 

Summary of Contents for Hydration Station 2000SM

Page 1: ... HAWS will not be liable for any damages caused by defective materials or poor workmanship except for replacements as provided above Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general special or consequenti...

Page 2: ...basin See maintenance section for details INSTALLATION PROCEDURE NOTES 1 WARNING Make certain power is disconnected before servicing to reduce risk of electrical shock 2 This unit is intended for indoor use only 3 For all plastic push in type fitting connections push tubing into fitting until it bottoms out to ensure a watertight connection To remove depress collet and pull tubing out 4 O rings on...

Page 3: ...or cartridge to seat note arrows on cartridge Attach filter monitor battery connector to filter monitor battery pack STEP 6 Use supplied magnetic key to unlock magnetic latch in plastic upper body panel place key on front of body panel opposite magnetic latch see Installation Drawing and pull panel open key will stay on panel by itself if it is in the right location Slots are provided in the upper...

Page 4: ...ever bacteria may build up in the drain therefore it is recommended to regularly clean the drain basin with a disinfectant such as Clorox Disinfecting Cleaner To access drain basin for cleaning open the upper body panel and remove the two screws holding the drain grate in place requires T 20 Torx driver STEP 3 Periodically assure that the sensor window is clean on the outside STEP 4 The filter has...

Page 5: ...e plugged into monitor b Replace batteries c Replace filter monitor 3 Continuous water flow a Solenoid valve sticking Clear obstruction or replace valve b Check sensor window for obstruction if it is obstructed it may have automatically shut off after 30 seconds and will not reactivate until the obstruction is removed c Contact Haws Technical Support 4 Unit does not activate a Check sensor window ...

Page 6: ...ISASSEMBLE SENSOR DAMAGE MAY RESULT STEP 2 With power on and door closed look closely at LEDs in nozzle assembly to confirm that the LEDs are flashing at reduced brightness This indicates that the unit is receiving power STEP 3 If LEDs are not flashing check the fuse and replace if necessary STEP 4 If fuse is good and LEDs are not flashing use a voltmeter to check for 120 VAC at the Open terminal ...

Page 7: ......

Page 8: ......

Page 9: ......

Reviews: