1. All DuraNiche™ underwater lighting fixture housings are Underwriters Laboratories (UL) Listed under File E 39338- Category

WBDT. These niches are New York City (NYC) Bureau of Electrical Control approved for use with low voltage (12 volt) lighting fix-
tures.  U.L. Listed for fresh water and complies with 1999 National Electrical Code [NEC].

2. DuraNiche™ model SP0600U and SP0607 underwater fixture housings are UL Listed only for use with Hayward Submersible

Light Fixture Series SP 0540, SP 0570, SP 0580 and SP 0580S. Model SP 0601 Underwater Light Fixture Housing (Niche) is UL
Listed for use with Hayward Submersible Light Fixture Series SP 0590.

3. All DuraNiche™ underwater lighting fixture housings must be installed in compliance with Article 680 of the National Electrical

Code (NEC) or other applicable electrical codes and with any applicable building codes. Article 680 requires that light fixtures be
installed with the top of the fixture lens at least 18 inches below the normal water level of the pool or spa.

4. All DuraNiche™ underwater lighting fixture housings are provided with three (3) UL Listed

Conduit Fittings. A 1" trade size -45° sweep elbow is provided for the purpose of directing
the conduit pipe towards the SP 0680/ SP 0681 Listed Junction Box location. A 1" conduit
pipe coupling is provided for the purpose of connecting the conduit pipe to the 45° sweep
elbow. A 1" - 3/4" reducer bushing is provided to permit the use (in conjunction with the 1"
coupling) of 3/4" conduit pipe.  These conduit fittings must be cemented to the fixture hous-
ing (niche), field supplied conduit pipe and to other conduit fittings using approved PVC
primer and cement. 

5. All DuraNiche™ underwater lighting fixture housings are provided with a combination bonding/grounding connector. The outside

connection is the bonding connector as required by Article 680-22 of the NEC. The NEC requires that the bonding wire be AWG 8
or larger. Local codes may require a continuous loop and may require that the bonding point on the fixture housing (niche) be
encapsulated. The inside connection is the grounding connector as required by Article 680-20 (b) of the NEC. The NEC requires
that where a nonmetallic conduit is used, an AWG 8 insulated copper conductor be installed in this conduit. This conductor is to be
connected to the niche grounding connector. The connector and wire termination must be encapsulated in 3M Inc. Scotch Cast
Wet Niche Potting Compound No. 2135 (UL File E130394) or equivalent  to protect such connection from the possible deteriorat-
ing effect of pool water.

6. All DuraNiche™ niches are equipped with Internally-threaded connection for pressure testing of conduit line before installing light.

HAYWARD

®

DuraNiche

SERIES

UNDERWATER LIGHTING FIXTURE HOUSINGS

MODEL NO. SP0600U-FOR CONCRETE POOLS
MODEL NO. SP0601U-FOR CONCRETE POOL/SPA
MODEL NO. SP0607U- FOR VINYL/FIBERGLASS POOLS

Approved for use by NYC
Department of Buildings

INSTALLATION INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Unlike metallic niches, DuraNiche™ niches are
injection-molded of PVC for superior performance,
non-corrosive durability and plumbing versatility -
plus the lowest installed cost. 
The ability to accept PVC over expensive metal
conduit enables DuraNiche™ to offer true bottom
line savings in materials, as well as time to install. 
DuraNiche™ comes in three models for concrete/gunite pools,
vinyl/ fiberglass pools, or for concrete/gunite spas. When paired
with a Hayward AstroLite™ or AstroLite II™ light fixture, you have
the best quality and value in a lighting system available anywhere.
To facilitate installation, all DuraNiche™ fixture housings are
packed with U.L. listed conduit fittings (reducer, elbow, and cou-
pling.)

IS0600UA-03 Rev A

SP0600U

SP0601U

SP0607U

IMPORTANT INFORMATION REGARDING ALL MODELS

45° ELBOW 

(SP0600M)

UL LISTED CONDUIT

FITTINGS

1” COUPLING

(SP0600N)

1” TO 3/4” 

REDUCER
(SP0600P)

Summary of Contents for DuraNiche

Page 1: ... by Article 680 22 of the NEC The NEC requires that the bonding wire be AWG 8 or larger Local codes may require a continuous loop and may require that the bonding point on the fixture housing niche be encapsulated The inside connection is the grounding connector as required by Article 680 20 b of the NEC The NEC requires that where a nonmetallic conduit is used an AWG 8 insulated copper conductor ...

Page 2: ...OID ANY INSPECTION AUTHORITY ISSUES WITH THIS REQUIREMENT 2 Once the niche s has been securely positioned wedged in the rebar it must be securely tied to the rebar with tie wire Before tying niche in place make certain that niche is vertical plumb and square to the form and that top of niche where retaining screw is located is at highest point at the 12 O Clock posiiton The flanges of Niche Models...

Page 3: ...sket in place Two large holes in gasket will fit over the pan heads of the securing screws 6 If vinyl lined pool install liner before proceeding with Step 7 7 Align second gasket not required for fiberglass pools without liner and face plate and fasten tightly to shell assembly with ten 10 No 13 x 1 flat head self tapping screws provided Use a properly sized Phillips screwdriver to tighten these h...

Page 4: ...III KM 333 7 Nave 2 E 46930 Quart De Poblet Valencia SPAIN TEL 34 6 152 3454 FAX 34 6 152 3357 Hayward IMG International Marketing Group 801 Corporate Center Drive Suite 110 Pomona CA 91768 USA Tel 909 620 4041 Fax 909 620 1249 For further information or consumer technical support please call East Coast 908 351 5400 West Coast 909 594 1600 or visit our web site at www haywardnet com 12 21 6 50 4 8...