background image

SWIMMING POOL HEAT PUMP UNIT

Installation & Instruction Manual

Model HP65A

Hayward Pool Products Canada, Inc.

T: 1-888-238-7665

www.haywardcanada.com

Summary of Contents for HP65A

Page 1: ...SWIMMING POOL HEAT PUMP UNIT Installation Instruction Manual Model HP65A Hayward Pool Products Canada Inc T 1 888 238 7665 www haywardcanada com ...

Page 2: ... 5 3 4 Swimming Pool Heat Pumps Plumbing 6 3 5 Swimming Pool Heat Pumps Electrical Connection 7 3 6 Initial Start up of the Unit 7 4 Usage and operation 8 4 1 The Functions of the LED Controller 8 4 2 How to Set Operation Parameters 8 4 3 Usage of the controller 10 5 Maintenance and inspection 11 5 1 Maintenance 11 5 2 Trouble Shooting Guide 11 6 Appendix 12 6 1 Connection of PCB Illustration 12 6...

Page 3: ...alified installer centre personnel or an authorised dealer HVAC Maintenance and operation must be carried out according to the recommended time and frequency as stated in this manual Use genuine standard spare parts only Failure to comply with these recommendations will invalidate the warranty The Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the temperature constant This ty...

Page 4: ...2 2 SPECIFICATIONS 2 1 Performance data of Swimming Pool Heat Pump Unit REFRIGERANT R410A ...

Page 5: ...3 2 SPECIFICATIONS 2 2 Dimensions for the Swimming Pool Heat Pump Unit Model HP65A HP65A A 1140 44 9 B 470 18 5 C 875 34 5 D 740 29 2 E 430 17 0 F 120 4 8 G 400 15 8 H 82 3 3 SIZE TYPE Unit mm inch ...

Page 6: ...r the installer Attention Please follow these steps when using for the first time 1 Open valve and charge water 2 Make sure that the pump and the water in pipe have been filled with water 3 Close the valve and start the unit ATTN It is necessary that the water in pipe inlet be higher than the pool surface Chlorinator cell Water outlet Pool Valve Water supply Water inlet Water pump Sand filter or o...

Page 7: ...it a continuous source of fresh air which reduces its efficiency and may prevent adequate heat delivery 3 3 How Close To Your Pool Normally the pool heat pump is installed within 7 5 metres of the pool The longer the distance from the pool the greater the heat loss from the piping For the most part the piping is buried Therefore the heat loss is minimal for runs of up to15 metres 15 metres to and ...

Page 8: ... unit for winterizing and to provide easier access should servicing be required Condensation since the heat pump cools the air down about 4 5 C water may condense on the fins of the horseshoe shaped evaporator If the relative humidity is very high this could be as much as several litres an hour The water will run down the fins into the basepan and drain out through the barbed plastic condensation ...

Page 9: ...the condensate drainage hose is properly attached and free of any blockages 6 Switch on the power supply to the unit then press the On Off key on the wire controller 7 Ensure that no ALARM code is displayed when the unit is ON see Trouble shooting guide 8 Set the water flow using the by pass valve see chapter 3 1 as described for each different model see the control panel or chapter 2 to obtain a ...

Page 10: ...1 Function of the LED controller User Interface and Usage as the following 4 2 Usage of the controller 1 Electrify After checking everything is okay electrify and enter into standby state with the screen showing as the following ...

Page 11: ...9 4 USAGE AND OPERATION ...

Page 12: ...10 4 USAGE AND OPERATION 4 Set Clock 6 KEYLOCK Keyboard lock ...

Page 13: ...he refrigerant system should only be serviced by a certified technician Check the power supply and cable connection often Should the unit begin to operate abnormally switch it off and contact your qualified technician Discharge all water in the water pump and water system so that freezing of the water inlet the pump or water system does not occur You should discharge the water at the bottom of the...

Page 14: ...12 6 APPENDIX 6 1 Connection of PCB Illustration ...

Page 15: ...13 6 APPENDIX 6 2 Wiring Diagram ...

Page 16: ...Titanium Condenser 9 Electrical Box Cover 29 N A Protection Cover 10 HPCX20000 14151 Electronic Expansion Valve 30 N A Right Panel 11 N A Back Panel 31 HPCXTEM1930 Water Outlet Sensor 12 HPCX2000 3508 Fan Motor Capacitor 32 HPCXTEM1930 Water Inlet Sensor 13 N A Terminal Block 2 Connections33 HPCX3400 2203 Drain Connector 14 HPCX2000 3524 Compressor Capacitor 34 N A Bottom Panel 15 HPCX20000 36035 ...

Page 17: ...15 ...

Page 18: ...void if the product is repaired or altered in any way by any persons or agencies other than those authorized by HAYWARD and is in lieu of all other warranties expressed or implied written or oral There are no implied warranties of merchantability or fitness for a particular purpose that apply to this product This warranty applies only within Canada At its option HAYWARD will replace or repair any ...

Reviews: