background image

 

Instruction manual switches with large electronic unit 05 

  

March 2021 

 

Instruction manual 

 

HB switches with large electronic unit 

 

Covers: HBSC2-SSR, HBSR-SSR, HBSO-SSR 

 

 

 

Functionality  

The switches are used for detecting liquid in gas or air (HBOR detect oil in liquid ammonia). The mechanical elements have 
different design because they are optimized to different liquids. The switches use the capacitive measuring principle and react to 
the difference in dielectric constant between liquid and gas. 

The switches have different calibration and parameter settings in the electronic unit. The basic electronic unit exist in two 
versions 24 V and 90-240 V, and it must match the mechanical part. 

Standard switches available from HB-products

 

Switches from HB-products are suited for different fluids, different temperature ranges and supply voltages.  There is a special 
program for oil switches. The two tables show the recommended products.  

Oil switches 

 

 

 

Summary of Contents for HBSC2-SSR

Page 1: ... switches use the capacitive measuring principle and react to the difference in dielectric constant between liquid and gas The switches have different calibration and parameter settings in the electronic unit The basic electronic unit exist in two versions 24 V and 90 240 V and it must match the mechanical part Standard switches available from HB products Switches from HB products are suited for d...

Page 2: ...and this means there is a risk that the switch will not detect oil or detect without oil For sensors installed in low temperatures condensation might occur and water run into the connection between the mechanical and electrical unit This might disturb the measurement Sensors designed for low temperatures has treaded union which is waterproof Labelling The switches are delivered as NO NC The switch...

Page 3: ... and take necessary precautions before attempting to make replacements or reparations to avoid collateral damage Disposal instructions The switch is built so the modules can easily be removed and sorted for disposal Electrical connection The switch exists in two versions one supplied with 24V AC DC and one with 90 240V AC The switch is delivered as NO normally open or NC normally closed and this r...

Page 4: ... can build up and disturb the measurement Switches pointing upwards can collect liquid which disturb the measurement Apply Teflon or liquid gasket on sensors with a conical thread For other thread types solid gasket is used Fasten the mechanical part with a suitable spanner tightening torque 80 150 Nm depending on thread type Mounting the electronic unit The electronic unit is mounted with either ...

Page 5: ...iled explanations of the individual fields will show up when the mouse is moved over the field Only the latest version of the tool has this feature To change the sensor from NO to NC or opposite you connect the switch to a pc using the USB cable Under basic settings you can change the alarm output signal in the dropdown menu After changing the value you store the data by clicking save to sensor Th...

Page 6: ... Water or moisture shortcut the sensor between the mechanical and electrical part Use a sensor with treaded union or dry the parts and make a suitable cover against water Sensor repair The sensor electronics are completely embedded and can therefore not be repaired In case of faults with the sensor it will typically only be necessary to replace the electronics If you have a faulty product please c...