background image

Heat & Glo  •  PIER-HVB-IPI, ST-HVB-IPI, LCOR-HVB-IPI, RCOR-HVB-IPI  •  2006-900  Rev. M•  8/06

1

Models:
Pier-HVB-IPI
ST-HVB-IPI
LCOR-HVB-IPI
RCOR-HVB-IPI

Underwriters

Laboratories Listed

In the Commonwealth of Massachusetts:

•  installation must be performed by a licensed

plumber or gas fitter;

• a CO detector shall be installed in the room

where the appliance is installed.

- Do not store or  use gasoline or other flam-

mable vapors and liquids in the vicinity of this
or any other appliance.

     -

What to do if you smell gas

• Do not try to light any appliance.

• Do not touch any electrical switch.

• Do not use any phone in your building.

• Immediately call your gas supplier from a

neighbor's phone. Follow the gas supplier's
instructions.

• If you cannot reach your gas supplier, call

the fire department.

- Installation and service must be performed by a

qualified installer, service agency, or the gas
supplier.

WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.

READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE 
MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.

1. This appliance may be installed in an af-

termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.

2. This appliance is only for use with the type

of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.

Please contact your Heat-N-Glo dealer with any
questions or concerns. For the number of your nearest
Heat-N-Glo dealer, please call 1-888-427-3973.

Printed in U.S.A.   Copyright 2006

Heat  & Glo, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044

WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.

Owner’s Manual

Installation and Operation

This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471,
5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165,
6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802,
6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250,
780403, 1418504 or other U.S. and foreign patents pending.

Summary of Contents for LCOR-HVB-IPI

Page 1: ...alled in an af termarket permanentlylocated manufac tured mobile home wherenotprohibited by local codes 2 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Please contact your Heat N Glo dealer with any questions or concerns For the number of your nearest Heat N Glo dealer plea...

Page 2: ...nches of the fireplace front READ and UNDERSTAND all instructions carefully before starting the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Fireplace section of the Owners Guide DO NOT USE this appliance if any part has been under water Immediately CALL ...

Page 3: ... Approvals 21 B Installing Vent Components 28 C Vent Termination 30 Step 4 Positioning Leveling and Securing the Fireplace 33 Step 5 The Gas Control System 33 Step 6 The Gas Supply Line 34 Step 7 Gas Pressure Requirements 34 Step 8 Wiring the Fireplace 35 Step 9 Finishing 37 Step 10 Installing Trim Logs Ember Material 38 Installing the Trim 38 Positioning the Logs 38 Shutter Settings 38 Glass Spec...

Page 4: ...ally grounded in accordance with local codes or in the absence of local codes with the National Electric Code ANSI NFPA No 70 in the United States or to the CSAC22 1 Canadian Electric Code in Canada These models may be installed in a bedroom or bed sitting room in the U S A and Canada 1Approvals and Codes High Altitude Installations U L Listed gas appliances are tested and approved with out requir...

Page 5: ...tion to ensure maximum safety and benefit Failure to follow these instructions will void the own er s warranty and may present a fire hazard The Heat Glo Warranty will be voided by and Heat Glo disclaims any responsibility for the following actions Installation of any damaged fireplace or vent system component Modification of the fireplace or direct vent system Installation other than as instructe...

Page 6: ...mm ELECTRICAL ACCESS GAS LINE ACCESS 34 3 4 882mm 4 1 16 102mm 4 1 2 114mm 4 3 4 121mm 2 5 16 58mm 37 7 16 950mm 32 5 16 820mm 21 533mm 42 1067mm 17 15 16 455mm 24 610mm 21 533mm 5 1 4 133mm 1 2 13mm 2 12 306mm Ø8 204mm 8 1 2 216mm REAR VENT COLLARS ELECTRICAL ACCESS GAS LINE ACCESS GAS CONTROLS LABELS SIDE GLASS DOOR TOP STANDOFFS TOP VENT COLLARS ...

Page 7: ... 46 5 8 1183mm 42 1067mm 32 5 16 820mm 21 533mm 36 3 16 919mm 2 5 16 58mm 4 3 4 121mm 4 1 16 102mm 4 1 2 114mm ELECTRICAL ACCESS GAS LINE ACCESS 12 305mm 4 1 2 114mm 2 9 16 64mm 24 610mm 8 1 2 216mm 34 3 4 882mm Ø8 204mm Ø8 204mm REAR VENT COLLARS ELECTRICAL ACCESS GAS LINE ACCESS GAS CONTROLS LABELS SIDE GLASS DOOR TOP STANDOFFS TOP VENT COLLARS ...

Page 8: ...mm 37 7 16 950mm ELECTRICAL ACCESS GAS LINE ACCESS 42 5 8 1082mm 2 5 16 58mm 21 533mm 24 1 8 612mm 8 1 2 216mm 21 533mm 42 1066mm 32 5 16 820m 17 15 16 455mm 2 9 16 64mm 1 2 13mm 4 5 1 4 133mm 12 305mm 29 1 4 743mm 7 1 4 184mm Ø8 204mm 10 254mm REAR VENT COLLARS ELECTRICAL ACCESS GAS LINE ACCESS GAS CONTROLS LABELS END GLASS DOOR TOP STANDOFFS TOP VENT COLLARS SIDE GLASS DOOR ...

Page 9: ...ding past the face of the fireplace is one inch 25 mm The metal ends of the fireplace may NOT be recessed into combustible construction Note Refer to Figure 4B for dimensions and appliance locations if installing a Pier HVB unit with a Catalina shelf and or marble package Note Refer to the Catalina installation instruction included with kit for assembly and installation Figure 4B 50 1 2 in 34 1 2 ...

Page 10: ...e to the ceiling is measured from the top of the unit excluding the standoffs see Figures 37 38 The distance from the unit to combustible construction is to be measured from the unit outer wrap surface to the com bustible construction NOT from the screw heads that se cure the unit together WARNING FRAMING DIMENSIONS ASSUME USE OF 1 2 INCH THICK WALL COVERING MATERIALS ON EXTERIOR OF FRAMING ONLYAN...

Page 11: ...42 1 2 23 35 3 4 48 ST HVB IPI 47 5 8 42 1 2 23 35 3 4 48 L RCOR HVB IPI 42 1 8 42 1 2 28 3 4 35 3 4 48 Figure 5 Framing Dimensions NOTE DIMENSIONS SHOWN IN INCHES Shows center of 10 x 12 vent framing holes for top and rear venting The center of the hole is one inch 25 4mm above the center of the horizontal vent pipe PIER HV IPI ST HV IPI L R COR HV IPI A C B D B C A A C B E ...

Page 12: ...ES OVERLAP 1 1 4 INCHES AT EACH JOINT Figure 6 DVP Series Direct Vent Component Specifications 5 inch inner pipe 8 inch outer pipe DVP90ST 12 9 16 11 1 4 7 1 4 1 1 4 TYP 1 2 TYP 8 9 16 DVP36 DVP48 48 24 36 4 6 DVP4 DVP6 12 DVP12 2 MIN DVP12A 12 3 16 MAX DVP24 9 7 8 45 0O 10 1 4 DVP45 14 1 4 ...

Page 13: ...configuration used Identifying Vent Components The vent systems installed on this gas fireplace may in clude one two or three 90 elbow assemblies The rela tionships of vertical rise to horizontal run in vent configura tions using 90 elbows MUST BE strictly adhered to The rise to run relationships are shown in the venting drawings and tables Refer to the diagrams on the next several pages NOTE Two ...

Page 14: ...e Restrictor into two pieces Do this by bending the part back and forth until it breaks see Figure 10 1 2 3 4 5 SETTINGS 1 2 3 4 5 4 Center the Flue Restrictor on vent and secure in place using two self tapping screws see Figure 11 STRAIGHT OUT HORIZONTALVENTING H Max Run 24 610 mm Figure 12 V CAP H 3 Match the amount of vertical in the system with the chart to find the appropriate position to set...

Page 15: ...IN 305mm 2 MAX 610mm 2 MIN 610mm 4 MAX 1 22m 3 MIN 914mm 6 MAX 1 83m 4 MIN 1 22m 8 MAX 2 4m 5 MIN 1 5m 10 MAX 3 0m 6 MIN 1 83m 12 MAX 3 6m V H 50 MAX 15 2m NATURAL GAS VENTING WITH ONE 90 ELBOW V FT H FT 900 Elbow on top 2 5 MAX 64mm 1 MIN 305mm 3 MAX 914mm 2 MIN 610mm 6 MAX 1 83m 3 MIN 914mm 9 MAX 2 7m 4 MIN 1 22m 12 MAX 3 6m 5 MIN 1 5m 15 MAX 4 5m 6 MIN 1 83m 18 MAX 5 5m V H 50 MAX 15 2m PROPANE...

Page 16: ... 2 MAX 610mm 2 MIN 610mm 4 MAX 1 22m 3 MIN 914mm 6 MAX 1 83m 4 MIN 1 22m 8 MAX 2 4m 5 MIN 1 5m 10 MAX 3 0m 6 MIN 1 83m 12 MAX 3 6m V H H1 50 MAX 15 2m NATURAL GAS VENTING WITH TWO 90 ELBOWS V V1 FT H FT 900 Elbow on top 2 5 MAX 64mm 1 MIN 305mm 3 MAX 914mm 2 MIN 610mm 6 MAX 1 83m 3 MIN 914mm 9 MAX 2 7m 4 MIN 1 22m 12 MAX 3 6m 5 MIN 1 5m 15 MAX 4 5m 6 MIN 1 83m 18 MAX 5 5m V V1 H 50 MAX 15 2m PROPA...

Page 17: ...m 2 MAX 610mm 2 MIN 610mm 4 MAX 1 22m 3 MIN 914mm 6 MAX 1 83m 4 MIN 1 22m 8 MAX 2 4m 5 MIN 1 5m 10 MAX 3 0m 6 MIN 1 83m 12 MAX 3 6m V H H1 50 MAX 15 2m H H1 12 MAX 3 6m H H1 18 MAX 5 5m NATURAL GAS VENTING WITH TWO 90 ELBOWS V FT H H1 FT 1 MIN 305mm 3 MAX 914mm 2 MIN 610mm 6 MAX 1 83m 3 MIN 914mm 9 MAX 2 7m 4 MIN 1 22m 12 MAX 3 6m 5 MIN 1 5m 15 MAX 4 5m 6 MIN 1 83m 18 MAX 5 5m V H H1 50 MAX 15 2m ...

Page 18: ...IN 610mm 4 MAX 1 22m 3 MIN 914mm 6 MAX 1 83m 4 MIN 1 22m 8 MAX 2 4m 5 MIN 1 5m 10 MAX 3 0m 6 MIN 1 83m 12 MAX 3 6m V V1 H H1 H2 50 MAX 15 2m H H1 H2 12 MAX 3 6m H H1 H2 18 MAX 5 5m NATURAL GAS VENTING WITH THREE 90 ELBOWS V V1 FT H H1 FT 1 MIN 305mm 3 MAX 914mm 2 MIN 610mm 6 MAX 1 83m 3 MIN 914mm 9 MAX 2 7m 4 MIN 1 22m 12 MAX 3 6m 5 MIN 1 5m 15 MAX 4 5m 6 MIN 1 83m 18 MAX 5 5m V V1 H H1 50 MAX 15 ...

Page 19: ...5mm 3 MAX 914mm 2 MIN 610mm 6 MAX 1 83m 3 MIN 914mm 9 MAX 2 7m 4 MIN 1 22m 12 MAX 3 6m 5 MIN 1 5m 15 MAX 4 5m 6 MIN 1 83m 18 MAX 5 5m V V1 H H1 50 MAX 15 2m PROPANE VENTING WITH THREE 90 ELBOWS V V1 FT H H1 FT 900 Elbow on top 2 MAX 610mm 1 MIN 305mm 2 MAX 610mm 2 MIN 610mm 4 MAX 1 22m 3 MIN 914mm 6 MAX 1 83m 4 MIN 1 22m 8 MAX 2 4m 5 MIN 1 5m 10 MAX 3 0m 6 MIN 1 83m 12 MAX 3 6m V V1 H H1 50 MAX 15...

Page 20: ... off the unit horizontally the elbow cover plate must first be removed from the unit see Figure 20 The elbow can be removed from the unit by aligning the seams of the elbow to the arrows on the surrounding heat shield see Figure 21 Position the elbow in the vertical position Snap in place with the starting collar Replace the elbow cover plate aligning it with the elbow and secure in place with the...

Page 21: ...locking each succeed ing component into place Ensure that each succeeding vent component is secure ly fitted and locked into the preceding component in the vent system Securing pipe sections with a maximum of two screws is recommended 90 elbows may be installed and rotated to any point around the preceding component s vertical axis If an el bow does not end up in a locked position with the pre ced...

Page 22: ...minations To attach and secure the termination to the last section of horizontal vent refer to the Cinch Pipe and Termination Cap installation instructions Push on and snap lock as described at the beginning of the Installing Vent Components section The termination kit should pass through the wall firestops from the exterior of the building Adjust the termination cap to its final exterior position...

Page 23: ... space spaces open only on one side and with an overhang are permitted with the dimensions specified for vinyl or non vinyl siding and soffits 1 There must be 3 feet minimum between termination caps 2 All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap 3 All gravity air intakes within 3 feet of a termination cap must be a minimum of ...

Page 24: ...ARE NECESSARY IN THE INTER EST OF SAFETY SEE THE FOLLOWING DIAGRAM FOR MINIMUM HEIGHTS PROVIDED THE TERMI NATION CAPISAT LEAST 20 INCHES FROMAVER TICAL WALLAND 2 FEET BELOW A HORIZONTAL OVERHANG NOTE This also pertains to vertical vent systems in stalled on the outside of the building Roof Pitch H min ft flat to 6 12 1 0 over 6 12 to 7 12 1 25 over 7 12 to 8 12 1 5 over 8 12 to 9 12 2 0 over 9 12 ...

Page 25: ...ided in the base pan for securing the unit to the floor The diagram below shows how to properly position level and secure the fireplace Figure 31 Proper Positioning Leveling and Securing of a Fireplace Step 5 The Gas Control System WARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL Figure 32 Gas Control System IPI PILOT WARNING CONTINUOUS 110 120 VAC SERVICE MUST BE WIRED DIRECTLY TO THE FIREPLACE J...

Page 26: ...er wrap does not exceed 2 in diameter and it does not penetrate the actual firebox Open the fireplace lower grille insert the gas supply line through the gas line hole and connect it to the shut off valve When attaching the pipe support the control so that the lines are not bent or torn After the gas line installation is complete all connec tions must be tightened and checked for leaks with a comm...

Page 27: ...e used as necessary Once power 110 VAC is restored disconnect red and black wire leads to extend battery life IGNITION MODULE 3V VALVE LOW VOLTAGE PLUG IN 3V TRANSFORMER NEUTRAL HOT GROUND FLAME SPARKER SENSOR REMOTE CONTROL SEE NOTE 1 IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR GROUND TO FIREPLACE CHASSIS VALVE TRANSFORMER 3 VAC ORG WHT ORG GRN WHT ON OFF WALL SWITCH BRN BRN BLK WHT BLK WHT ...

Page 28: ...ional Accessories Optional fan and remote control kits require that 110 120 VAC be wired to the factory installed junction box before the fireplace is permanently installed NOTE If any of the original wire as supplied with the appliance must be replaced it must be replaced with the type 105o C rated wire FAN JUNCTION BOX SPEED CONTROL RHEOSTAT TEMPERATURE SENSOR SWITCH SEE DETAIL A DETAIL A SCALE ...

Page 29: ...tible material such as wood can be placed on the top edge and sides of the fireplace Hearth Extensions A hearth extension may be desirable for aesthetic reasons However ANSI or CAN CGA testing standards do not require hearth extensions for gas fireplace appliances Figure 40 Sealant Material ST HVB IPI TOP EDGE SIDE EDGE PIER HVB IPI and L RCOR HVB IPI TOP EDGE SIDE EDGE 0 GAP 0 GAP Figure 39 NOTE ...

Page 30: ... the logs might need to be repositioned slightly to avoid excessive flame impingement Step 10 Installing Trim Logs Ember Material Glass Specifications Model Type PIER HVB IPI TEMPERED ST HVB IPI TEMPERED L RCOR HVB IPI TEMPERED Heat Glo fireplaces manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures as defined by the CPSC The tempered glass has been t...

Page 31: ...a single layer of ember material Save the remaining ember materials for use during fire place servicing The bag of embers provided is sufficient for 3 to 5 applications Replace the glass door and a front trim door on the unit Figure 42 Placement of the Ember Material Optional Ember Light Kit Emberkit MS Ember Light Bulb Replacement In the lower gas valve compartment you will find three ac cess pan...

Page 32: ...grilles for obstructions Before lighting the fireplace double check the unit for possible obstructions that could be blocking the vent ter minations or the front grilles Double check for faulty components Any component that is found to be faulty MUST BE re placed with an approved component Tampering with the fireplace components is DANGEROUS and voids all war ranties A small amount of air will be ...

Page 33: ...ng the logs Cleaning Flame Sensor Rod IPI Systems Frequency Periodically By Qualified service technician Task Make a visual check of the straight flame sensor rod Use emery cloth to carefully remove any existing white film or deposits Checking Flame Patterns Flame Height Frequency Periodically By Qualified service technician Home owner Task Make a visual check of your fireplace s flame patterns Ma...

Reviews: