background image

Heat & Glo  •  RED40-N-AU, RED40ST-N-AU •  2294-900 Rev. C  •  4/13

1

Models:

RED40-N-AU

RED40ST-N-AU

Owner’s Manual

Installation and Operation

DO NOT DISCARD THIS MANUAL

NOTICE

•  Leave  this  manual  with 

party responsible for use 

and operation.

DO NO

T

DISCARD

•  Important  operating 

and  maintenance 

instructions included.

•  Read, understand and follow 

these instructions for safe 

installation and operation.

Ref No: GMK10107

AS4553:2008

WARNING: If the information in these 

instructions is not followed exactly, a fire 

or explosion may result causing property 

damage, personal injury, or death.

WARNING

This appliance has been supplied with an integral barrier 

to prevent direct contact with the fixed glass panel. DO 

NOT operate the appliance with the barrier removed. 

Contact your dealer or Hearth & Home Technologies if the 

barrier is not present or help is needed to properly install one.

HOT SURFACES

Glass and other surfaces are hot during 

operation AND cool down.

Hot glass will cause burns.

• 

DO NOT

 touch glass until it is cooled

•  NEVER allow children to touch glass

•  Keep children away

•  CAREFULLY  SUPERVISE  children  in  same  room  as 

fireplace.

•  Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable 

materials.

•  DO NOT 

place articles on or against this appliance.

•  Keep  clothing,  furniture,  draperies  and  other  flammable 

materials away.

This  is  a  room  sealed  appliance  and  no  other  ventilation  is 

required than what is provided.

• 

DO  NOT

  USE  OR  STORE  FLAMMABLE 

MATERIALS NEAR THIS APPLIANCE.

• 

DO NOT

 SPRAY AEROSOLS IN THE VICIN-

ITY OF THIS APPLIANCE WHILE IT IS IN 

OPERATION.

•  What to do if you smell gas 

 

DO NOT

 try to light any appliance.

DO NOT

 touch any electrical switch. 

DO 

NOT

 use any phone in your building.

-  Immediately call your gas supplier from a 

neighbor’s phone. Follow the gas supplier’s 

instructions.

-  If you cannot reach your gas supplier, call 

the fire department.

•  Installation  and  service  must  be  performed 

by a qualified installer, service agency, or the 

gas supplier.

WARNING!  DO NOT modify this appliance. 

Summary of Contents for RED40-N-AU

Page 1: ...peration AND cool down Hot glass will cause burns DO NOT touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials DO NOT place articles on or against this appliance Keep clothing furniture dr...

Page 2: ...ters K 46 3 4 1187 L 7 178 M 50 1 8 1273 N 25 1 16 637 O 17 7 8 455 P 9 227 Q 3 3 4 95 R 1 1 2 38 S 8 1 2 216 T 14 1 2 368 Location Inches Millimeters A 52 1321 B 13 3 16 335 C 10 3 4 273 D 42 3 4 1086 E 48 1 8 1222 F 21 533 G 4 102 H 4 3 4 121 I 42 15 16 1090 J 17 1 8 435 C B A D E F G H I J K L O M N P T Q R S RED40ST N AU ...

Page 3: ... 50 1 4 31 0 0 1 36 Millimeters 254 1187 438 1276 787 0 0 25 914 F I G H E MEASURE FROM TOP OF FIREPLACE OPENING C A B D C B D A Figure 5 4 Clearances to Combustibles RED40 MINIMUM FRAMING DIMENSIONS A B C D E F G H I J Rough Opening Vent Pipe Rough Opening Height Rough Opening Depth Rough Opening Width Clearance to Ceiling Combustible Floor Combustible Flooring Behind Appliance Sides of Appliance...

Page 4: ...ld and ceiling firestops as specified Failure to keep insulation or other material away from vent pipe may cause fire WARNING Note Use DVP Series components only V1 Minimum H1 Maximum 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 6 ft 1829 mm 3 ft 914 mm 9 ft 2743 mm 4 ft 1219 mm 12 ft 3658 mm 5 ft 1524 mm 15 ft 4572 mm 6 ft 1829 mm 18 ft 5486 mm 7 ft 2134 mm 21 ft 6401 mm 8 ft 2438 mm 24 ft 7315 mm V1 H1 6...

Page 5: ...orizontal Termination Venting with 2 elbows Note Use DVP Series components only V1 Minimum H1 H2 Maximum 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 6 ft 1829 mm 3 ft 914 mm 9 ft 2743 mm 4 ft 1219 mm 12 ft 3658 mm V1 H1 H2 63 ft 19 2 m Maximum H1 H2 23 ft 7 1 m Maximum Note 12 in 305 mm minimum verti cal is required prior to attaching any elbow to the appliance ...

Page 6: ...1 Top Vent Horizontal Termination continued Figure 7 6 V1 V2 Minimum H Maximum 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 6 ft 1829 mm 3 ft 914 mm 9 ft 2743 mm 4 ft 1219 mm 12 ft 3658 mm 5 ft 1524 mm 15 ft 4572 mm V1 V2 H1 H2 63 ft 19 2 m Maximum H1 H2 23 ft 7 1 m Maximum Note 12 in 305 mm minimum verti cal is required prior to attaching any elbow to the appliance ...

Page 7: ...estrictor can be located in the appliance manual bag Figure 7 8 Exhaust Restrictor Notice Before painting contact your dealer for information on the appropriate high temperature paint 4 In some applications such as those where the fire place is elevated off the floor the vent restrictor may be painted but painting is not required 5 Recommended restrictor usage 20 to 30 ft 6 m to 9 1 m 4 in 102 mm ...

Page 8: ... Use DVP Series components only V1 V2 Minimum H Maximum 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 4 ft 1219 mm 3 ft 914 mm 9 ft 2743 mm 4 ft 1219 mm 12 ft 3658 mm 5 ft 1524 mm 15 ft 4572 mm V1 H1 V2 63 ft 19 2 m Maximum H1 H2 23 ft 7 1 m Maximum Note 12 in 305 mm minimum verti cal is required prior to attaching any elbow to the appliance ...

Page 9: ...lbows Note Use DVP Series components only V1 V2 Minimum H1 H2 Maximum 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 4 ft 1219 mm 3 ft 914 mm 9 ft 2743 mm 4 ft 1219 mm 12 ft 3658 mm 5 ft 1524 mm 15 ft 4572 mm V1 V2 H1 H2 63 ft 19 2 m Maximum H1 H2 23 ft 7 1 m Maximum Note 12 in 305 mm minimum verti cal is required prior to attaching any elbow to the appliance ...