background image

 

Ph: 03 9562 3455    |    E: sales@thermofilm.com.au

 

www.heatstrip.com.au 

HEATSTRIP® Classic With Remote  (THH

-

AR)

 

Classic with Remote (THH

-

AR) 

 

Summary of Contents for THH2400AR

Page 1: ...1 Ph 03 9562 3455 E sales thermofilm com au www heatstrip com au HEATSTRIP Classic With Remote THH AR Classic with Remote THH AR ...

Page 2: ...l mounting height of 2 3m to 2 5m and maximum mounting height of 2 7m HEATSTRIP Max THX THXDCR models is an ultra high temperature heater used for uncovered or open indoor or outdoor areas with an ideal mounting height of 2 3 m to 2 7m and up to a maximum 3 5m for protected indoor applications HEATSTRIP Intense THY THYW models is an instant high temperature heater perfect for any exposed outdoor o...

Page 3: ...o internal moving parts ensuring quiet and virtually maintenance free operation Australian Designed Designed and engineered in Australia HEATSTRIP is fully backed by a 24 month residential warranty and 12 month commercial warranty Stylish design The Heater that is a Design Feature The attractive HEATSTRIP Classic comes with a standard black face and black anodised alloy rear casing Easy to use The...

Page 4: ...P can provide effective and energy efficient comfort heating for undercover outdoor and indoor open areas HEATSTRIP has successfully enabled many entertainment venues such as restaurants pubs and clubs to utilise their outdoor dining areas day and night through all seasons Within your workplace or business HEATSTRIP can provide comfort heating for designated outdoor smoking and leisure areas as we...

Page 5: ...inal at 50 60 Hertz Single Phase CONNECTION 3 Core Cable 2 5mm2 APPROVALS AUSTRALIA NZ MOUNTING HEIGHT MINIMUM RECOMMENDED MAXIMUM 2 1 m 2 3 m to 2 5 m 2 7 m in a fully enclosed outdoor area For higher ceiling heights units can be lowered using optional bracket kits or extension poles see Page 19 MOUNTING OPTIONS Suitable for ceiling wall beam fixed umbrella and recess mounting Also available for ...

Page 6: ...NONE NO THH2400US A 240V NORTH AMERICA 240 2400 10 1364 x165 x 115 7 NONE NO THH3200US A 240V NORTH AMERICA 240 3200 13 3 1774 x 165 x 115 9 NONE NO THH2400US A 208V NORTH AMERICA 208 2400 11 53 1364 x 165 x 115 7 NONE NO THH3200US A 208V NORTH AMERICA 208 3200 15 4 1774 x 165 x 115 9 NONE NO THH1300AJP JAPAN 100 1300 6 3 924 x 165 x 48 5 1000 YES 100V THH1400AJP JAPAN 200 1400 7 5 924 x 165 x 48 ...

Page 7: ...door gas heater is based on 25 00 average to fill a 9kg gas bottle and average running time of 9 hours 25 00 9 hours 2 78 per hour 2 Electricity rate of 25 cents kWh 3 All calculations are excluding GST 2 4kW x 0 20 cents 0 60 cents per hour 3 2kW x 0 20 cents 0 80 cents per hour Calculations of yearly running cost are based on 180 hours usage 180 hours x 2 78 500 40 yearly running cost for outdoo...

Page 8: ... or indoor workstations Often it is more practical and efficient to spot heat high use areas Spot heating will reduce both the initial capital cost as well as the ongoing running costs Spot heating will allow the area to be zoned meaning only the areas that are being used are heated such as tables in a restaurant or outdoor alfresco area Option 1 and 2 show a comparison between heating an entire a...

Page 9: ...er and the temperature decreases as you move away from the heater It highlights the importance of maintaining recommended mounting heights and if possible positioning the heater directly above the area to be heated Note that the temperature is the same for the 2 models regardless of the wattage However as the size increases and the length of the unit increases the radiant footprint will be longer ...

Page 10: ...or a protected outdoor area a minimum of 500W m2 is required For indoor spot heating a minimum heating capacity of 400W m2 is recom mended The table below outlines the coverage of each HEATSTRIP Classic with remote model based on 3 differ ent scenarios with direct overhead mounting For example for an outdoor area that is protected from pre vailing winds by walls café blinds etc Model THH2400AR wil...

Page 11: ...ns the most effective method is to spot heat a table or similar area The diagrams below provide an easy selection guide for the approximate model and quantity of heaters required to heat common residential table settings Selections are based on HEATSTRIP Classic with remote being mounted at 2 4m from the floor in a fully enclosed undercover outdoor area ...

Page 12: ...the table is within 2 5m of the wall For mounting heights more than 2 7m we recommend the use of the optional accessories to reduce the height of the heater to 2 3m 2 5 m This will increase the effectiveness of your HEATSTRIP Refer to the Mounting Accessory section for more information Electrical connections GPO s should not be located at the back of the heater They should be located outside the p...

Page 13: ... Do not use this heater in small rooms when they are occupied by persons not capable of leaving the room on their own unless constant supervision is provided Angled Wall Installation Ceiling Installation Angled Ceiling Installation Lights fans and sprinklers Lights fans and sprinklers Surface Below Heater Lights fans and sprinklers Surface Below Heater Surface Below Heater ...

Page 14: ... there are range of mounting options available refer to diagrams below The HEATSTRIP Classic with remote can be mounted directly to the ceiling angled downwards on a wall fitted flush with the ceiling suspended on chains or poles attached to beams or poles or mounted end to end Refer to the following pages for more detailed information on each mounting option ...

Page 15: ... mounting brackets These adjustable brackets allow direct ceiling or PART No PACKAGED DIMENSIONS mm WEIGHT kg MATERIAL ZBRAK 113B 125 x 150 x 40 0 2 ALLOY MODEL X THH2400AR 1000 THH3200AR 1470 Adding chains to Standard Mounting Bracket Putting the Standard Mounting Bracket together ...

Page 16: ...tly install the HEATSTRIP into a ceiling They are available for all HEATSTRIP Classic models and are supplied as a one piece unit suitable for mounting individual heaters Flush mounting can be used with plaster or timber lined ceiling materials An ideal mounting height is 2 3m 2 5m with a maximum ceiling height of 2 7m in an outdoor enclosed environment Maximum mounting heights should be strictly ...

Page 17: ...mounting is preferable to direct overhead mounting applications include heating over tables lounges work stations etc These kits are suitable for all HEATSTRIP Elegance Classic models Instructions Fix the wall bracket in the desired location using 6 x 8 mm fasten ers that will be more than adequate to safely support the bracket and the HEATSTRIP unit When bracket is installed lift the heater into ...

Page 18: ...p easy and effective option for lowering the HEATSTRIP Classic from high ceilings The bracket is designed to be used with chains or wires There can be multiple chain wire arrangement options as per the diagram below PART No PACKAGED DIMENSIONS mm WEIGHT kg MATERIALS SUITABLE FOR MODELS THHAC 002 300 x 150 x 50 1 Alloy THH 2400AR THHAC 003 1200 x 120 x 50 2 Alloy THH3200AR Suspension mount bracket ...

Page 19: ...m 900mm and 1200mm The extension mount brackets utilise components from the standard bracket kit which is supplied with each heater and it provides an extra 100mm of length PART No DIMENSIONS mm WEIGHT kg MATERIALS NOTES THYAC 047 300 x 20 x 20 0 21 ALLOY Kit Includes 2 x 300mm Extension Poles Black THYAC 048 600 x 20 x 20 0 38 ALLOY Kit Includes 2 x 600mm Extension Poles Black THYAC 049 900 x 20 ...

Page 20: ...hest heat setting The timer function has 0 24 hour timer This feature is ideal for applications such as alfresco areas restaurant dining assem bly line production etc when continuous heat is not required The timer also reduces the likelihood of heaters being inadvert ently left turned on Remote pairing All units operate using the same remote control frequency therefore multiple heaters can be oper...

Page 21: ... On Off Button Press this button once to turn on off for operation Timer Timer function 0 24 hour press through hours to set the timer Receiver is located on the To use the remote controller aim the transmitter to the heater A line of sight transmission is required for the unit to function The controller does not have a protec tion rating The controller must be kept away from wet applications Sign...

Page 22: ... components by Thermofilm or an authorized representative of Thermofilm Thermofilm does not participate in any site related costs or labour expenses incidental to replacement of parts repairing removing installing servicing transportation or handling of parts to complete products and assumes no liability on parts repaired or replaced without written authorisation Thermofilm shall not be liable for...

Reviews: