Page 1: ...Installation and Operation Manual HouseLink HL 10P LV 12 5 2022 Installation and Operation Manual HouseLink HL 10P LV ...

Page 2: ...etup 3 BinTrac Indicator Setup 4 Operation 4 Status LEDs 4 Testing Calibration 4 Output Specification 5 Operational Specifications 6 Addendum A 7 Addendum A Wiring Diagram 8 is a registered trademark of HerdStar LLC Copyright 2022 HerdStar LLC All rights reserved Printed in the USA 1400 Madison Avenue Suite 504 Mankato MN 56001 PH 507 344 8005 FAX 507 344 8009 www herdstar com ...

Page 3: ...rac Indicator to the COM OUT terminal in the HouseLink HL 10P LV See Figure 1 3 Connect the HouseLink HL 10P LV to the house control by connecting the EXC IN to the EXC terminal and the EXC IN to the EXC terminal of the house control 4 Finally connect the mV V OUT from the HouseLink HL 10P LV to the SIG of the house control and the mV V from the HouseLink HL 10P LV to the SIG of the house control ...

Page 4: ...This indicates the unit is not communicating but has power NO LIGHT The unit doesn t have an adequate power source Testing Calibration Once the unit is wired and the dip switches are set up correctly the unit can be put into one of five test modes These modes are useful when setting up and testing with the house controls Please note Due to increased filtering effects on house controllers for best ...

Page 5: ... Total Weight 1 00 75 1 00 50 0 00 0 1 00 50 2 00 100 3 00 150 4 00 200 4 50 225 4 50 250 mV V of Total Weight 1 00 75 1 00 33 3 0 00 0 1 00 33 3 2 00 66 6 3 00 100 4 00 133 33 4 50 150 4 50 175 1 00 1 00 0 00 1 00 2 00 3 00 4 00 4 50 4 50 2 00 1 00 0 00 1 00 2 00 3 00 4 00 5 00 100 0 100 200 300 mV V Output of Total Weight 2mV V Output mV V 1 00 1 00 0 00 1 00 2 00 3 00 4 00 4 50 4 50 2 00 1 00 0...

Page 6: ...rovals N A Wiring Type Screw terminal block Power Requirements 2 25 VDC 2 75 VDC 70 mA max Output Signal Type Simulates 3mV V 360 ohm load cell Maximum Output Signal Range 1 0 mV V to 4 5 mV V Default Output Value 1 0 mV V Maximum Load Capacitance No limit Zero Accuracy 35 mV V Span Accuracy 0 2 of reading Linearity Error 0 02 of full scale Span Temperature Stability 35 ppm C Output Signal Resolut...

Page 7: ...t up for peripheral devices Follow the procedure shown in the HouseLink HL 10P LV Installation and User Guide 9 Calibrate the Maximus control using the calibration method for empty and full weight and using the HouseLink HL 10P LV test mode to output an empty and full weight simulated weight reading Please note Due to increased filtering effects on house controllers for best calibration results wa...

Page 8: ...Installation and Operation Manual HL 10P LV Installation Manual Ver 1 0 8 Part Number MAN 000024 Addendum A Wiring Diagram ...