Recycling Instructions

Parts Included:

Modular Power Duplex

Power Block

Power Block Harness

#10-12 x 1/2” 

Phillips Pan 

Head Tapping 

Screw

Modular Power Entry

A

D

B

C

E

Tools Needed:

Power Driver

#2 Phillips Bit

Electrically interconnected units must be mechanically

interconnected.

WARNING

!

Modular Power Entry, 

New York

Block-to-Block Jumper

F

G

BRE04.

BRE01.

BRE05.

BRE02.

BRE03.XX08

BRE03.XX04

Disconnect power before installation.  Failure to do so can

cause electrical shock and personal injury.

WARNING

!

All electrical connections to building electrical sources

must be made by a qualified electrician according to

national, state and local electrical codes.

NOTICE

Summary of Contents for Locale Modular Electrical

Page 1: ...cling Instructions Parts Included Modular Power Duplex Power Block Power Block Harness 10 12 x 1 2 Phillips Pan Head Tapping Screw Modular Power Entry A D B C E Tools Needed Power Driver 2 Phillips Bit Electrically interconnected units must be mechanically interconnected WARNING Modular Power Entry New York Block to Block Jumper F G BRE04 BRE01 BRE05 BRE02 BRE03 XX08 BRE03 XX04 Disconnect power be...

Page 2: ...oduct information available at the time of publication The right is reserved to make changes in design and specifications at any time without notice and also to discontinue products Part no 1bc57y rev B 2 1 Position Power Block B or Power Block Harness C onto Base Frame 2 Secure to Frame with Pan Head Screws D 3 Locate mounting holes for mounting Modular Power Duplex A A B D D ...

Page 3: ... right is reserved to make changes in design and specifications at any time without notice and also to discontinue products Part no 1bc57y rev B 3 4 Secure Modular Power Duplex A to inside wall of Base with 4 Pan Head screws D 5 Insert end of Modular Power Duplex into Power Block Make sure connection fully engages 6 Feed End of Modular Power Entry E through opening in side of Base 7 Remove bottom ...

Page 4: ...served to make changes in design and specifications at any time without notice and also to discontinue products Part no 1bc57y rev B 4 8 Run end of Power Block B through inner wall of Base 9 Insert end of harness into Power Block Make sure connection fully engages 10 When making connections to Power Block Make sure reference arrow point in same direction 1 Remove Lid from Modular Power Entry F Mod...

Page 5: ...time of publication The right is reserved to make changes in design and specifications at any time without notice and also to discontinue products Part no 1bc57y rev B 5 2 Locate mounting holes for mounting Modular Power Entry F 3 Secure Modular Power Entry F to inside wall of Base with 2 screws supplied with product 4 Insert end of Power Block into Block Make sure connection fully engages Supplie...

Page 6: ...of publication The right is reserved to make changes in design and specifications at any time without notice and also to discontinue products Part no 1bc57y rev B 6 5 After hard wiring J Box from an outside power source by a qualified electrician return cover to J Box 1 Insert Block to Block Jumper G through opening in side of Base 2 Remove Bottom Shelf Feed Jumper through inner wall of base Block...

Page 7: ...ed on the latest product information available at the time of publication The right is reserved to make changes in design and specifications at any time without notice and also to discontinue products Part no 1bc57y rev B 7 4 Connect Modular Power Duplex to Power Block 3 Insert end of Jumper into Bottom Port of Power Block Make sure connection fully engages ...

Page 8: ...d to make changes in design and specifications at any time without notice and also to discontinue products Part no 1bc57y rev B 8 8 WIRE POWER BLOCK WIRING DIAGRAMS 4 2 2 4 HOTS 2 NEUTRALS 2 GROUNDS NOTE CIRCUITS 1 2 3 4 CORRESPOND TO CIRCUITS DUPLEX RECEPTACLES A B C D ALLOWABLE CIRCUIT COMBINATIONS 1 2 3 4 1 2 3 4 1 2 3 4 NOTE CIRCUITS 1 3 4 CORRESPOND TO CIRCUITS DUPLEX RECEPTACLES A C D ALLOWA...

Page 9: ... available at the time of publication The right is reserved to make changes in design and specifications at any time without notice and also to discontinue products Part no 1bc57y rev B 9 10 WIRE POWER BLOCK WIRING DIAGRAMS 4 4 2 4 HOTS 4 NEUTRALS 2 GROUNDS ALLOWABLE CIRCUIT COMBINATIONS 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 ALLOWABLE CIRCUIT COMBINATIONS CIRCUITS 1 2 3 4 1 2 3 4 OR 1 2 3 4 ...

Page 10: ...without notice and also to discontinue products Part no 1bc57y rev B 10 Disassembly and Recycling Materials Identification and Segregation Where possible plastic components are marked with ASTM recycling codes Use these codes to identify material type for recycling Non marked components should be treated as mixed plastic Ferrous metals can be identified using a small magnet for recycling Non ferro...

Reviews: